DOSTMANN LOG40 Data Logger for Temperature and External Sensor
Introduction
Thank you very much for purchasing one of our products. Before operating the data logger please read this manual carefully. You will get useful information for understanding all functions
Delivery contents
- Data logger LOG40
- 2 x Battery 1.5 Volt AAA (already inserted)
- USB protection cap
- Mounting kit
Kindly note / Safety Instructions
- Check if the contents of the package is umdamaged and complete.
- Remove the protection foil above the display.
- For cleaning the instrument please do not use an abrasive cleaner only a dry or wet piece of soft cloth. Do not allow any liquid to the interior of the device.
- Please store the measuring instrument in a dry and clean place.
- Avoid any force like shocks or pressure to the instrument.
- No responsibility is taken for irregular or incomplete measuring values and their results, the liability for subsequent damages is excluded!
- Keep these devices and the batteries out of reach of children.
- Batteries contain harmful acids and may be hazardous if swallowed. If a battery is swallowed, this can lead to serious internal burns and death within two hours. If you suspect a battery could have been swallowed or otherwise caught in the body, seek medical help immediately.
- Batteries must not be thrown into a fire, short-circuited, taken apart or recharged. Risk of explosion!
- Low batteries should be changed as soon as possible to prevent damage caused by leaking. Never use a combination of old and new batteries together, nor batteries of different types.
- Wear chemical-resistant protective gloves and safety glasses when handling leaking batteries.
Equipment and usage
The measuring device is used for recording, alarming, and visualizing temperature and, with external sensors, also for relative humidity and pressure. Areas of application include the monitoring of storage and transport conditions or other temperature, moisture and/or pressure-sensitive processes. The logger has a built-in USB port and can be connected without cables to all Windows PCs, Apple computers or tablets (USB adapter might be required). The USB port is protected by a plastic cap. Beside the actual measurement result, the display shows MIN- MAX- and AVG-measurements of each measurement channel. The bottom status line shows battery capacity, logger mode and alarm status. The green LED flashes every 30 seconds during recording. The red LED is used to display limit alarms or status messages (battery change …etc.). The logger also has an internal buzzer that supports the user interface. This product is exclusively intended for the field of application described above. It should only be used as described within these instructions.Unauthorized repairs, modifications or changes to the product are prohibited and void any warranty!
How to use device
Device description
-
Hanging loop
-
Affichage LCD cf. fig. B
-
LED : rouge/vert
-
Mode button
-
Start / Stop button
-
Battery case on the back side
-
USB cover below USB-connector (the USB port is also used to connect external sensors)
-
Units for measured value / extrema
-
EXT = external probe
-
AVG =average value,
-
MIN = minimum value,
-
MAX = maximum value (no symbol) = current measurement value
-
Measurement
-
Status line (from left to right)
- Battery indication,
- Data logger is recording,
- Data logger has been configured,
- i.O., (ohne ► Symbol) und
- Alarm aufgetreten nicht i.O. (ohne ► Symbol)
If the display has been deactivated (display off via Software LogConnect), the battery symbol and the symbol for recording (►) or configuration (II) are still active in Line 4 (status line).
Device start-up
ration take out the instrument from the packaging, remove the display foil.
The logger is already preset and ready for start. It can be used immediately
without any software! By pressing any button or moving the instrument before
first operation the instrument displays FS (factory setting) for 2 seconds,
afterwards measurements are displayed for 2 minutes. Then the instrument
display switch off. Repeated key hit or movement reactivates the display.
Factory settings
Note the following default settings of the data logger before first use. By
using the LogConnect (see below 5.2.2.1 Configuration Software Log Connect)
software, the setting parameter can easily be changed:
- Recording Interval : 15 min.
- Measuring interval : During recording the measurement interval and recording interval is the same! If the logger has been not started (NOT RECORDING) the measuring interval is every 6 seconds for 15 minutes, afterwards the measuring interval is every 15 min. for 24 hours, afterwards the measuring interval is once per hour. If you press any button or move the device it will start again to measure each 6 seconds.
- Start possible by : Key press
- Stop possible by : USB connect
- Alarm : off
- Alarm delay : 0 s
- Show measurements on display : on
- Power-Save mode for display : on
Power-Save Mode for Display
The Power-Save Modes is activated as a standard. The display switches off when
for 2 minutes no button has been pressed or the instrument has been not moved.
The logger is still active, only the display is switched off. The internal
clock runs. Moving the logger will reactivate the display.
Windows Software for LOG40
The instrument is already preset and ready for start. It can be used without
any software! However, there is a Windows Application free for downloading.
Please note the free-to-use link: see below 5.2.2.1 Configuration Software Log
Connect
Configuration Software Log Connect
By this software the user can change configuration parameter like measuring
interval, start delay(or other start parameter), creating alarm levels or
changing the internal clock time The Software Log Connect contains an online
help. Download free LogConnect software: www.dostmann-
electronic.de
Erster Start & Aufzeichnung starten
- Press button for 2 seconds, beeper sounds for 1 second, the actual date and time will be displayed for 2 further seconds.
- LED lights green for 2 sconds – logging has started!
- LED blinks green every 30 sec.
Display in Auto-Mode (Display shows all measurement channel in a 3 seconds sequence)
By using the Software LogConnect, the presets can easily be changed. See below Configuration Software Log Connect
External Sensors
External sensors are plugged into the USB port on the data logger. Only if the
sensors are connected when the logger is started will they be recorded!
Restart recording
See 5.3. First start / start recording. The logger is started by default by
button and stopped by USB port plug-in. The measured values are plotted
automatically to the PDF file.
NOTE: When you restart the existing PDF file is overwritten.
Important! Always save the generated PDF files to your PC. If LogConnect is open when connecting the loggers and AutoSave is selected in Settings (Default), the log results are copied to a backup location immediately by default.
Display used memory (%), date and time
By briefly pressing the start button (after logger start), MEM, occupied
memory in percent, MEM, day/month, Year and time each for 2 seconds displayed.
Stop recording / create PDF
Connect logger to an USB port. Beeper sounds for 1 second. LED blinks green
until result PDF is created (can take up to 40 seconds). The symbol ►
disappears in the status line. Now the logger is stopped. The Logger is shown
as removable drive LOG40. View PDF and save. PDF will be overwritten with next
log start!
Note : With the next recording the Extrema (Max- and Min-value), and the AVG-value will be reset.
Stop recording by button.
To stop the Logger via button it is necessary to change the configuration by
Software LogConnect. If this setting is done the start button is also the
stopp button
Description of PDF result file
Filename: e.g.
LOG32TH_14010001_2014_06_12T092900.DBF
- LOG32TH : Device 14010001: Serial
- 2014_06_12: Start of recording (date) T092900: time: (hhmmss)
- Description : Log run info, edit with LogConnect* software
- Configuration : preset parameters
- Summary : Overview of measurement results
- Graphics : Diagram of measured values
- Signature : Sign PDF if required
- Measurement OK :Measurement failed
USB-Connection
For configuration the instrument has to be connected to the USB-port of your
Computer. For configuration please read the according to chapter and the use
the online direct help of the Software LogConnect
Display Modes and Mode – Button: EXT, AVG, MIN, MAX
-
AUTO mode
The display alternately shows every 3 seconds: Minimum (MIN) / Maximum (MAX) / Average (AVG) / current temperature. The displayed meas channel can be identified by the physical unit (°C/°F = temperature, Td + °C/°F = dewpoint, %rH = humidity, hPa = air pressure) along with the extension symbols <no symbol> = current measurement value, MIN= Minimum, MAX= Maximum, AVG=average. AUTO mode gives a quick overview on the current measurement values of all channels. Pressing the MODE key (left key) leaves AUTO mode and enters MANUAL mode: -
MANUAL mode
MODE key flips through all available measurement values, following the sequence current value (no symbol), minimum (MIN), maximum (MAX), average (AVG) and AUTO (AUTO-Mode). MANUAL mode is handy to view any meas channel along with the main meas channel. Eg. air pressure maximum vs. main channel air pressure. Hit MODE key until display shows AutO to resume AUTO mode. EXT designates an external sensor. MANUAL mode is handy to view any meas channel
Special function of Mode-Button
Set marker
To mark special events during the record, markers can be set. Hit MODE key for
2.5 seconds until a short beep sounds (see mark on PDF Fig. C). The marker is
stored along with the next measurement (respect record interval!) .
Reset MAX-MIN buffer
The logger has a MIN/MAX function to record extreme values for any period. Hit
the MODE key for 5 seconds, until a short melody sounds. This restarts the
measurement period. One possible use is the finding of day and night exterme
temperatures. The MIN/MAX function runs independent of data recording.
Please note:
- At start of record, the MIN/MAX/AVG buffer is also reset to show MIN/MAX/AVG values that fit the recording
- During recording, resetting the MIN/MAX/AVG buffer will force a marker.
Batterie-Status-Anzeige
- The empty battery symbol indicates that the battery needs to be replaced. Device will only work correctly for 10 more hours.
- The battery symbol indicates according to the battery status beween 0 and 3 segments.
- If battery symbol is flashing, the battery is empty. The instrument does not operate!
- Open battery compartment screw with a Phillips screwdriver. Replace the two batteries. Polarity is indicated on battery case bottom. Note the polarity. If the battery change is OK, light up for both LEDs light up for approx. 1 second and a signal tone sounds.
- Close battery compartment.
Note! After replacing the battery please check the correct time and date of the internal clock. For setting the time see next chapter or 5.2.2.1 Configuration software LogConnect.
Set Date and Time after battery replacement via button
After battery replacement or power interrupt the instrument automatically
changes into the configuration mode to set date, time and interval. If no
button will be pressed for 20 seconds the unit proceeds with the last date and
time in memory:
- Press N= No changing of date and time, or
- Press Y= Yes for changing date and time
- Press Mode-button to increase the value,
- press Start-button for jumping to the next value.
- After date-time-request the Interval (INT) can be changed.
- Press N= No to abort changes, or Press
- Y=Yes to confirm changes
Alerts
Beeper sounds once each 30 seconds for 1 second, red LED blinks each 3 seconds
– measured values exceeds selected alarm settings (not with standard
settings). Via Software LogConnect (5.2.2.1 Configuration software
LogConnect.) alarm levels can be set. If an alarm level has been occurred a X
will be displayed on the display bottom. On the corresponding PDF-report the
alarm status will be indicated, too.If the measurement channel is displayed
where an alarm occurred the X on the right bottom of the display is blinking.
The X disappears when the instrument has been restarted for recording! Red LED
blinks once each 4 seconds. Replace battery. Blinks twice or more each 4
sconds. Hardware fault!
Explanation of symbols
This sign certifies that the product meets the requirements of the EEC directive and has been tested according to the specified test methods.
Waste disposal
This product and its packaging have been manufactured using high-grade materials and components which can be recycled and reused. This reduces waste and protects the environment. Dispose of the packaging in an environmentally friendly manner using the collection systems that have been set up. Disposal of the electrical device Remove non-permanently installed batteries and rechargeable batteries from the device and dispose of them separately. This product is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE). This product must not be disposed of in ordinary household waste.
As a consumer, you are required to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compatible disposal. The return service is free of charge. Observe the current regulations in place! Disposal of the batteries Batteries and rechargeable batteries must never be disposed of with household waste. They contain pollutants such as heavy metals, which can be harmful to the environment and human health if disposed of improperly, and valuable raw materials such as iron, zinc, manganese or nickel that can be recovered from waste.
As a consumer, you are legally obliged to hand in used batteries and rechargeable batteries for environmentally friendly disposal at retailers or appropriate collection points in accordance with national or local regulations. The return service is free of charge. You can obtain addresses of suitable collection points from your city council or local authority. The names for the heavy metals contained are: Cd = cadmium, Hg = mercury, Pb = lead. Reduce the generation of waste from batteries by using batteries with a longer lifespan or suitable rechargeable batteries. Avoid littering the environment and do not leave batteries or battery-containing electrical and electronic devices lying around carelessly. The separate collection and recycling of batteries and rechargeable batteries make an
WARNING! Damage to the environment and health through incorrect disposal of the batteries!
Marking
CE-conformity, EN 12830, EN 13485, Suitability for storage (S) and transportation (T) for food storage and distribution (C), Accuracy classification 1 (-30..+70°C), according to EN 13486 we recommend a recalibration once per year
Storage and cleaning
It should be stored at room temperature. For cleaning, use only a soft cotton cloth with water or medical alcohol. Do not submerge any part of the thermometer
DOSTMANN electronic GmbH Mess- und Steuertechnik Waldenbergweg 3b D-97877 Wertheim-Reicholzheim Germany