DOSTMANN Electronic ScanTemp 450 Infrared Thermometer with Circle Laser Instruction Manual
- June 12, 2024
- DOSTMANN electronic
Table of Contents
- DOSTMANN ScanTemp 450 Infrared Thermometer with Circle Laser
- Product Information
- Product Usage Instructions
- Default Screen
- Mode Key Functions
- Power and Battery Information
- Technical Specifications
- Before you start using it
- Field of operation and all the benefits
- Features
- For your safety
- Parts description
- Trouble shooting
- Waste disposal
- Specifications
- Table of emissivity values
- ABOUT COMPANY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DOSTMANN ScanTemp 450 Infrared Thermometer with Circle Laser
Product Information
Product Name | ScanTemp 450 |
---|---|
Model Number | 5020-0450 |
Website | www.dostmann-electronic.de |
Product Usage Instructions
Parts Description:
Part | Description |
---|---|
LCD | Display screen |
Taste Up | Button to increase values |
Taste Down | Button to decrease values |
Taste Mode | Button to switch modes |
Thermoelementeingang | Thermocouple socket for temperature measurements |
Taste Messen | Button to initiate temperature measurement |
Infrarotlinse | Infrared lens for non-contact temperature measurement |
Laser | Laser pointer for aiming at the target |
Batteriefach | Battery compartment |
Default Screen
The default screen on the ScanTemp 450 displays the following:
- Infrared function: The default emissivity is set to 0.95.
Mode Key Functions
Press the Mode key to scroll through different display functions:
- Press the Emissivity key to adjust the emissivity from 0.10 to 1.00.
- Press the Meas. key to display the surface temperature.
- Keep pressing the Mode key for additional functions such as Maximum (MAX), Minimum (MIN), Different between MAX and MIN (DIF), and Average (AVG) readings during the last measurement period.
- In PRB mode, connect a thermocouple to the thermocouple socket and the temperature will be displayed beside the PRB icon.
Power and Battery Information
The ScanTemp 450 uses two AAA, 1.5V batteries.
- If the “Low Battery” icon appears, replace the batteries immediately.
- Turn off the instrument before replacing the batteries.
- The instrument may malfunction if the batteries are replaced without turning it off.
Technical Specifications
Messbereich Infrarot | Measurement range for infrared: N/A |
---|---|
Arbeitstemperatur | Operating temperature: N/A |
Lagertemperatur | Storage temperature: N/A |
Ansprechzeit | Response time: 1 second |
Einstellbarer Emissionsgrad | Adjustable emissivity: 0.10 to 1.00 (step size: |
0.01)
Mode| Available modes: MAX, MIN, DIF, AVG, HAL, LAL, PRB, Lock
Batteriestandzeit| Battery life: minimum 140 hours in continuous operation
Abmessungen| Dimensions: 141 x 134 x 42 mm
Gewicht| Weight: 186 g (including batteries)
Before you start using it
- Please make sure to read the instruction manual carefully.
- Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use. We shall not be liable for any damage occurring as a result of non-following of these instructions.
- Likewise, we take no responsibility for any incorrect readings and for any consequences which may result from them.
- Please take particular note of the safety advice!
- Please keep this instruction manual for future reference.
Field of operation and all the benefits
-
The ScanTemp 450 infrared thermometer is a non-contact infrared thermometer with Thermocouple connector. For the infrared part, simply aim the thermometer at the target and press the measurement button to display the surface temperature in less than a second. Plug in the specific thermocouple
(not included), ScanTemp 450 may take contact temperature as high as 1400 °C. -
The distance to target diameter ratio (field of view) is 12:1. For accurate reading, please make sure the target size is smaller than the spot size.
Features
- 2 x 1,5 Volt AAA batteries included
- Large LCD screen, with backlight
- Friendly user interface: 3-Key with trigger
- With high-end arithmetic: Max; Min and DIF; AVG mode
- Auto Power Off in 1 minute
- Precision K type thermocouple thermometer inside
For your safety
- The device should only be used as described within these instructions.
- Unauthorized repairs, modifications or changes to the product are prohibited.
Caution! Risk of injury:
- Never point the device towards anyone’s eyes.
- Keep this device and the battery out of the reach of children.
- Batteries must not be thrown into a fire, short-circuited, taken apart or recharged. Risk of explosion!
- Batteries contain harmful acids. Low batteries should be changed as soon as possible to prevent damage caused by leaking.
- Never use a combination of old and new batteries together, or batteries of different types. Wear chemical resistant protective gloves and safety glasses when handling leaking batteries.
- Remove the battery if you do not use the device for a long period of time.
Important information on product safety!
EMC/RFI
- Readings may be affected if the device is operated with in radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
- Do not place your device near extreme temperatures, vibrations or shocks.
- The ScanTemp 450 should be stored at room temperature between –20 to +65°C.
- The lens should be kept clean at all times.
- The sensor lens is the most delicate part of the ScanTemp. The lens should be kept clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol, allowing the lens to fully dry before using the ScanTemp 450.
- Do not leave the device near objects of high temperature.
Parts description
Simply aim the ScanTemp450 at the measure target and press the Meas. key 6 to display the surface temperature.
- LCD
- Up key
- Down key
- Mode key
- Thermocouple socket
- Measuring key
- Infrared Lens
- Laser
- Battery cover
Default Screen
Infrared function
ScanTemp 450 is supplied with a default emissivity of 0.95.
Press Mode key 4 for scrolling more display function as follows:
ScanTemp will automatically shut off if left idle for more than 60 sec, unless in PRB mode.
Thermocouple probe scan function:
- Press the mode key 4 until PRB appears: on the LCD.
- Connect the thermocouple with Scan Temp 450’s thermocouple socket 5 and put the probe in or on the target, the temperature will be displayed beside the ”PRB” icon.
- ScanTemp 450 will automatically shut off if left idle for more than 12 min in PRB mode.
- The measurement range: -64 to +1400 °C.
After measure high temp, the probe may remain HOT for a while.
Key pad:
In Default:
Max, Min, DIF, AVG, HAL, LAL, PRB
| Press Lock key for infrared LOCK mode ON/OFF.
---|---
Press °C/°F key for °C or °F transferred.
In all modes: Hold the Measuring key 6| Press Lock key for backlight function
ON/OFF.
Press °C/°F key for Laser function ON/OFF.
Batterie:
- When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with two AAA, 1.5V batteries.
- Please note: It is important to turn the instrument off before replacing the battery otherwise the ScanTemp 450 may malfunction..
Trouble shooting
Waste disposal
- This product and its packaging have been manufactured using high-grade materials and components which can be recycled and reused. This reduces waste and protects the environment.
- Dispose of the packaging in an environmentally friendly manner using the collection systems that have been set up.
- Disposal of the electrical device: Remove non-permanently installed batteries and rechargeable batteries from the device and dispose of them separately. This product is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE). This product must not be disposed of in ordinary household waste. As a consumer, you are required to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compatible disposal. The return service is free of charge. Observe the current regulations in place!
Disposal of the batteries:
- Batteries and rechargeable batteries must never be disposed of with household waste. They contain pollutants such as heavy metals, which can be harmful to the environment and human health if disposed of improperly, and valuable raw materials such as iron, zinc, manganese or nickel that can be recovered rom waste. As a consumer, you are legally obliged to hand in used batteries and rechargeable batteries for environmentally friendly disposal at retailers or appropriate collection points in accordance with national or local regulations. The return service is free of charge.
- You can obtain addresses of suitable collection points from your city council or local authority.
- The names for the heavy metals contained are: Cd = cadmium, Hg = mercury, Pb = lead. Reduce the generation of waste from batteries by using batteries with a longer lifespan or suitable rechargeable batteries. Avoid littering the environment and do not leave batteries or battery-containing electrical and electronic devices lying around carelessly. The separate collection and recycling of batteries and rechargeable batteries make an important contribution to relieving the impact on the environment and avoiding health risks.
WARNING! Damage to the environment and health through incorrect disposal of the batteries!
Explanation of symbols
This sign certifies that the product meets the requirements of the EEC
directive and has been tested according to the specified test methods.
Specifications
- Measurement range Infrared: -60 .. +500 °C (-76 .. +932 °F)
- Temperature range Thermocouple: -64 to +1400 °C (-83.2 to +1999 °F)
- Operating environment: 0 .. +50 °C (32 .. 122°F)
- Storing conditions: -20 .. +65 °C (-4 .. 149°F)
- Response time: 1 second
- Optical resolution: 12:1
- Emissivity: 0.10~1.00 step 0.01
- Mode : MAX, MIN, dIF, AVG, HAL, LAL, PRB, Lock)
- Battery life: min 140 hours continuous use (without laser and backlight).
- Dimension: 141 x 134 x 42 mm
- Weight: 186 grams including batteries
Note: Subject to change without notice.
Table of emissivity values
Table of emissivity values of common materials:
No part of this manual may be reproduced without written consent of Dostmann-
Electronic. The technical data are correct at the time of going to print and
may change without prior notice. The latest technical data and information
about your product can be found by entering your product number on our
homepage.
www.dostmann-electronic.de
ABOUT COMPANY
- DOSTMANN electronic GmbH Mess- und Steuertechnik
- Waldenbergweg 3b
- D-97877 Wertheim-Reicholzheim Germany
- Phone: +49 (0) 93 42 / 3 08 90
- E-Mail: info@dostmann-electronic.de
- Internet: www.dostmann-electronic.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>