PLANET Technology LRE-101C 1-Port 10-100TX Over Coaxial Long Reach Ethernet Extender User Manual

October 29, 2023
Planet Technology

PLANET Technology LRE-101C 1-Port 10-100TX Over Coaxial Long Reach Ethernet Extender

Trademarks

Copyright © PLANET Technology Corp. 2022.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.

Disclaimer

PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose.
PLANET has made every effort to ensure that this User’s Manual is accurate;
PLANET disclaims liability for any inaccuracies or omissions that may have occurred.
Information in this User’s Manual is subject to change without notice and does not represent a commitment on the part of PLANET.
PLANET assumes no  responsibility for any inaccuracies that may be contained in this User’s Manual.
PLANET makes no commitment to update or keep current the information in this User’s Manual, and reserves the right to make improvements to this User’s Manual and/or to the products described in this User’s Manual, at any time without notice.
If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and suggestions.

FCC Statement

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference  when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense

ISEDC Statement

CAN ICES-003(A) / NMB-003(A)
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

CE Mark Warning

This device is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.

Energy Saving Note of the Device

This power required device does not support Standby mode operation. For energy saving, please remove the power cable to disconnect the device from the power circuit. Without removing power cable, the device will still consume power from the power source. In view of Saving the Energy and reducing the unnecessary power consumption, it is strongly suggested to remove the power connection for the device if this device is not intended to be active.

WEEE Warning

To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately.

Revision

PLANET Gigabit Ethernet over Coaxial Converter User’s Manual
Model: LRE-101C
Revision: 1.0 (Sep. 2022)
Part No.: 2350-AA3A30-000

Package Contents

Thank you for purchasing PLANET LRE-101C 1-Port 10/100TX over Coaxial Long Reach Ethernet Extender. In the following sections, the term “EoC Converter” means the LRE-101C.
Open the box of the EoC Converter and carefully unpack it. The box should contain the following items:

LRE-101C DC 5V/2A Power Adapter

If any of these are missing or damaged, please contact your dealer immediately; if possible, retain the carton including the original packing material, and use them again to repack the product in case there is a need to return it to us for repair.

Hardware Introduction

Physical Dimensions

Dimensions (W x D x H): 94 x 70.3 x 26.2mm

Front View
  • LRE-101C Front Panel

  • 10/100TX RJ45 connector

  • BNC female connector for Long Reach

  • LEDs for power, Ethernet and Long

LRE-101C LED Indicators
The rich diagnostic LEDs on the front panel can provide the operating status of individual port and whole system.

System

LED Color Function
PWR Green Lit: Indicates that the EoC Converter has power.

Off: Indicates that the EoC Converter has no power.

Long Reach Ethernet interface

LED Color Function
LNK Green Lit: Indicates that the Long Reach Ethernet link is

established.
Off: Indicates that the port is link-down.

DIP Switch Setting

In the PtMP setting, it can be one master and more than one slave with BNC T connector.

LED Color Function
Master Green Lit: Indicates that the LRE-101C is functioned as a Master.

Off: Indicates that the LRE-101C is functioned as a Slave.

Rear View

LRE-101C Rear Panel

  • DIP switch: Master/Slave mode selectable
  • DC jack (DC input) for power adapter

DIP Switch

The EoC Converter provides a selectable 2-position DIP switch. When switching to “Master” , it supports PtMP, meaning it can be one master and more than one slave with BNC T connector.

DIP Function
Master The LRE-101C is functioned as a Master.
Slave The LRE-101C is functioned as a Slave.

By default, the 2-position DIP switch is set in the “Master” position and is operated as “CO”. To operate, slide the DIP 1 switch to the “Slave” position. Just slide it to whatever position you prefer to fulfill your application requirement

Power Information

The LRE-101C requires 5V DC, 2A power input, which conforms to the bundled AC adapter. Should you have the issue of power connection, contact your local sales representative.

In some areas, installing a surge suppression device may also  help to protect your EoC Converter from being damaged by unregulated surge or current to the EoC Converter or the power adapter.

Product Specifications

Product LRE-101C

Hardware Specifications
LAN Ethernet interface| 1 10/100BASE-TX RJ45 Copper port, auto-negotiation /auto-MDI/MDI-X
Cabling| Cat5e UTP or above
Maximum

Distance

| 100 meters
Maximum

Frame Size

| 1522 bytes
Long Reach Interface| 1 BNC female Ethernet over Coaxial
Cabling| Coaxial cable: 75 ohm

RG-6/U cable, less than 12Ω/1000 ft RG-59/U cable, less than 30Ω/1000 ft

Maximum

Distance

| Max. 2000 with data transmission

(6,561ft.)

Long Reach Ethernet Standard| IEEE 1901
Modulation Type| Wavelet-OFDM
Security| 128-bit AES encryption
Frequency

Band

| 2~28MHz
Performance*| Distance| Data Rate

(Upstream/Downstream)

200m| 94/94Mbps
600m| 94/94Mbps
800m| 88/87Mbps
1000m| 76/73Mbps
1200m| 61/58Mbps
1400m| 45/43Mbps
Long Reach Interface| Performance*| 1600m| 35/33Mbps
1800m| 34/23Mbps
2000m| 3/8Mbps
Functionality| DIP Switch| Select Master or Slave mode
Dimensions (W x D x H)| 97 x 70.3 x 26 mm
Weight| 194g
Housing| Metal
Power Requirement| 5V DC, 2A external power
LED Indicators| Power: Green
LAN: Green, 10/100Mbps LNK/ACT
Long Reach : Green, LNK
Master: Green
__|
Standards Conformance
Standards Compliance| IEEE 802.3/802.3u Ethernet standard compliant IEEE 802.3x Full-duplex flow control

IEEE 802.1q Tag VLAN Transparent, Multicast pass-through

Regulatory Compliance| FCC Part 15 Class A, CE
Environment
Temperature| Operating: 0~50 degrees C Storage: -10~70 degrees C
Humidity| Operating: 5~95% (non-condensing) Storage: 5~95% (non-condensing)

  • The actual data rate will vary in the quality of the coaxial cables and environmental factors

Installations

Wall-mount Installation

Step 1 : Find a suitable wall to mount the LRE-101C.
Step 2 : Screw two screws on the w

Step 3 : Hang the LRE-101C on the screws from the wall.
Step 4 : Repeat Chapter 2.4 Power Information on power supply to the LRE- 101C.

Before mounting the device to the wall, please check the location of the electrical outlet and the length of the Ethernet cable.

Chassis Installation and Rack Mounting

To install the EoC Converter in a 10-inch or 19-inch Converter Chassis with standard rack, follow the instructions described below.
Step 1: Place your LRE-101C on a hard flat surface, with the front panel positioned towards your front side.
Step 2: Carefully slide in the module until it is fully and firmly fitted into the slot of the converter chassis.

Step 3: Attach a rack-mount bracket to each side of the Converter Chassis with supplied screws attached to the package.
Step 4: After the brackets are attached to the Converter Chassis, use suitable screws to securely attach the brackets to the rack.
Step 5: Proceed with Step 4 and Step 5 of the 4.1 Installation section to connect the network cabling and supply power to your Converter Chassis.

You must use the screws supplied with the mounting brackets.
Damage caused to the parts by using incorrect screws would Caution invalidate your warranty.

Optional DIN-rail Installation

There are two DIN-rail holes on the left side of the LRE-101C that allows to be easily installed by DIN-rail mounting. PLANET optional DIN-rail mounting kit – RKE-DIN — can be ordered separately. Refer to the following steps for the DIN-rail mounting of the LRE-101C:

Step 1: Screw the DIN rail on the LRE-101C.

Step 2 : Now slide the DIN rail into the track.

Step 3: Check whether the DIN rail is tightly on the track.

You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty.

Applications

The EoC Converter does not require any software configuration. Users can immediately use any feature of this product simply by attaching the cables and turning the power on. There are some key limitations on the EoC Converter. Please check the following items.

Point-to-Point Application — LAN to LAN Connection

One set of the EoC Converter could be used to link two local area networks that are located in different places. Through the coaxial cable, it could set up  a 100Mbps backbone, but one EoC Converter must be Master (CO mode) and the other one is Slave (CPE mode

Point to Point Application

Connecting Standalone PC

Refer to the following procedures to set up the LRE-101C LAN to LAN connection.

  1. [LAN1] Set the LRE-101C in LAN 1 to be in the Master mode from the DIP switch.
  2. [LAN2] Set the LRE-101C in LAN 2 to be in the Slave mode from the DIP switch.
  3. Power on the LRE-101C Master and Slave at both sides by connecting its power source.
  4. Master or Slave LED will illuminate correspondingly.
  5. Connect coaxial cable from LAN1 LRE-101C to BNC port of the LAN2 LRE-101C.
  6. LNK LED will blink to illuminate at both LRE-101C units.
  7. Connect the LRE-101C Ethernet LAN port to other network device via regular Cat5e UTP cable.
LRE-101C Point to Multi-point Application (IP surveillance)

Building an IP surveillance system

Refer to the following procedure to set up an IP surveillance system with many pairs of the LRE-101C:

  1. Set the LRE-101C to be in the Master or Slave mode from the DIP switch on the rear panel.
  2. Power on the LRE-101C by connecting its power source.
  3. Power LED will illuminate.
  4. Connect coaxial cable to the Long Reach ports of two LRE-101C units.
  5. LNK LED will illuminate and blink.
  6. Connect Ethernet port to IP cameras via regular Cat. 5, 5e or 6 cable.
  7. Install the NVR and monitor and connect to one Ethernet switch.
  8. You can get data transmissions from all IP cameras.

Performance Tab

  • LRE-101C Upstream/Downstream Performance
Coaxial\Distance (meter) (Upstream/Downstream) Unit: Mbps
200 94
500 94
600 94
800 88
1000 76
1200 61
1400 45
1600 35
1800 34
2000 3

*** The actual data rate will vary in the quality of the coaxial cables and environmental factors

Troubleshooting

SYMPTOM:
LNK LED does not light up after wire is connected to the Long Reach port.
CHECKPOINT:
Please note you must use one LRE-101C in Master mode and the other LRE-101C in Slave mode to make connection to each other work
SYMPTOM:
TP LED does not light after cable is connected to the port.
CHECKPOINT:

  1. Verify you are using the Cat5e or better cable with RJ45 connector to connect to the port.
  2. If your device (like LAN card) supports auto-negotiation, please try to manually set at a fixed speed of your device to solve this issue.
  3. The LRE-101C and the connected device’s power are on or not.
  4. The port’s cable is firmly seated in its connectors in the switch and in the associated device
  5. The connecting cable is good and with the correct type.
  6. The connecting device, including any network adapter, is functional.

Customer Support

Thank you for purchasing PLANET products. You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team
PLANET online FAQs:https://www.planet.com.tw/en/support/faq
Switch support team mail address:support@planet.com.tw

Copyright © PLANET Technology Corp. 2022.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners

FAQs

What is the best distance for LRE-101C?

In order to guarantee the stability and better quality of network, we suggest the distance should not exceed 700m (Cat.5 UTP) and 1200m (Phone wire).

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Planet Technology User Manuals

Related Manuals