Planet Technology IGS-10020MT Industrial L2+ Multi-Port Full Gigabit Managed Ethernet Switches Installation Guide
- June 11, 2024
- Planet Technology
Table of Contents
Industrial L2+ Multi-Port Full Gigabit
Managed Ethernet Switches
IGS-10020MT/IGS-10080MFT
IGS-12040MT/IGS-20040MT
Quick Installation Guide
Package Contents
Thank you for purchasing PLANET Industrial L2+ Multi-Port Gigabit Managed Ethernet Switches, such as IGS-10020MT, IGS-10080MFT, IGS-12040MT and IGS- 20040MT. The descriptions of these models are as follows:
IGS-10020MT| Industrial 8-Port 10/100/1000T + 2-Port 1G/2.5G SFP Managed
Switch
---|---
IGS-10080MFT| Industrial 6-Port 100/1000X SFP + 2-Port 1G/2.5G SFP + 2-Port
10/100/1000T Managed Switch
IGS-12040MT| Industrial 8-Port 10/100/1000T + 2-Port 100/1G SFP + 2-Port
1G/2.5G SFP Managed Switch
IGS-20040MT| Industrial 16-Port 10/100/1000T + 4-Port 100/1000X SFP Managed
Switch
Industrial L2+ Managed Switch” mentioned in this Quick Installation Guide refers to the above four models.
Open the box of the Industrial L2+ Managed Switch and carefully unpack it. The box should contain the following items:
- The Industrial L2+ Managed Switch x 1
- Quick Installation Guide x 1
- DIN-rail Kit x 1
- Wall Mounting Kit x 1
- DB9 to RJ45 Interface RS232 Console Cable x 1 (Only IGS-10020MT doesn’t have console interface.)
- Dust Cap (Please refer to the table below.)
Item | RJ45 Dust Cap | SFP Dust Cap |
---|---|---|
IGS-10020MT | 8 | 2 |
IGS-10080MFT | 3 | 8 |
IGS-12040MT | 9 | 4 |
IGS-20040MT | 17 | 4 |
If any item is found missing or damaged, please contact your local reseller for replacement.
Requirements
- Workstations running Windows XP/2003/2008/2012/Vista/7/8/10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols.
Serial Port Connection (Terminal)
- The above Workstations come with COM Port (DB9) or USB-to-RS232 converter.
- The above Workstations have been installed with terminal emulator, such as Hyper Terminal included in Windows XP/2003, putty or tera term.
- Serial cable — one end is attached to the RS232 serial port, while the other end to the RJ45 console port of the Industrial L2+ Managed Switch.
Ethernet Port Connection
- Workstations are installed with Ethernet NIC (Network Interface Card)
- Network cables — Use standard network (UTP) cables with RJ45 connectors.
- The above PC is installed with Web browser.
Note
It is recommended to use Chrome 98.0.xxx or above to access the Industrial L2+
Managed Switch. If the Web interface of the Industrial L2+ Managed Switch is
not accessible, please turn off the anti-virus software or firewall and then
try it again.
Wiring the Power Inputs
The Upper Panel of the Industrial L2+ Managed Switch indicates a DC inlet power socket and consists of one terminal block connector within 6 contacts. Please follow the steps below to insert the power wire.
-
Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2.
IGS-10020MT: 12-48V DC, 24V AC
• IGS-10080MFT: 12-48V DC, 24V AC
• IGS-12040MT: 12~72V DC, 24V AC
• IGS-20040MT: 9~48V DC, 24V AC
-
Tighten the wire-clamp screws for preventing the wires from loosening.
Item | Positive (+) Pin | Negative (-) Pin |
---|---|---|
IGS-10020MT | Pin 1 / 5 | Pin 2 / 6 |
IGS-10080MFT
IGS-12040MT
IGS-20040MT
The wire gauge for the terminal block should be in the range from 12 to 24 AWG.
3.1 Grounding the Device
Users MUST complete grounding wired with the device; otherwise, a sudden
lightning could cause fatal damage to the device.
Terminal Setup
To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Industrial L2+ Managed Switch. The console port of the Industrial L2+ Managed Switch is DCE already, so that you can connect the console port directly through PC without the need of null modem.
A terminal program is required to make the software connected to the Industrial L2+ Managed Switch. Putty or Tera Term may be a good choice.
- Run terminal program on the OS.
- When the following screen appears, make sure that the COM port should be configured as:
- Baud: 115200
- Parity: None
- Data Bits: 8
- Stop Bits: 1
- Flow Control: None
4.1 Logging on to the Console
Once the terminal has been connected to the device, power on the Industrial
L2+ Managed Switch and the terminal will display “running testing procedures”.
- There are three switches (IGS-12040MT, IGS-10080MFT and IGS-20040MT) that come with the RJ45 type console interface.
- The following console screen is based on the IGS 12040MT; the display of the IGS-12040MT is the same as that of the IGS-10080MFT and IGS-20040MT.
Then, the following message asks to log in user name and password as shown in Figure 4-3. Please enter the factory default user name “admin” and password “admin”.
User name: admin
Password: admin
- For security reason, please change and memorize the new password after this first setup.
- Only accept command in lowercase letter under console interface.
4.2 Configuring IP Address
The Industrial L2+ Managed Switch is shipped with default IP address shown
below:
IP Address: 192.168.0.100
Subnet Mask: 255.255.255.0
To check the current IP address or modify a new IP address for the Industrial
L2+ Managed Switch, please use the procedure as follows:
Display of the current IP Address
- At the “#” prompt, enter “show ip interface brief”.
- The screen displays the current IP address shown in Figure 4-4.
To check the current IP address or modify a new IP address for the Industrial
L2+ Managed Switch, please use the procedure as follows:
Display of the current IP Address
-
At the “#” prompt, enter “show ip interface brief”.
-
The screen displays the current IP address shown in Figure 4-4.
Configuration of the IP Address -
At the “#” prompt, enter the following command and press
as shown in Figure 4-5.
The previous command would apply the following settings for the Industrial L2+ Managed Switch.
IP Address: 192.168.1.100
Subnet Mask: 255.255.255.0
-
Repeat step 1 to check if the IP address has changed.
Storing the current switch configuration -
At the “#” prompt, enter the following command and press
.
# copy running-config startup-config
If the IP is successfully configured, the Industrial L2+ Managed Switch will
apply the new IP address setting immediately. You can access the Web interface
of the Industrial L2+ Managed Switch through the new IP address
If you are not familiar with the console command or the related parameter,
enter “help” anytime in console to get the help description.
Starting Web Management
The following shows how to start up the Web Management of the
Industrial L2+ Managed Switch. Note the
Industrial L2+ Managed
Switch is configured through an Ethernet connection. Please make sure the
manager PC must be set to the same IP subnet address.
For example, the default IP address of the Industrial L2+ Managed Switch is
192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a
number between 1 and 254, except 100), and the default subnet mask is
255.255.255.0.
5.1 Logging in to the Industrial L2+ Managed Switch
- Use Chrome 98.0.xxx or above for Web browser and enter IP address http://192.168.0.100 (the factory-default IP address) to access the Web interface.
2. When the following dialog box appears, please enter the default user name “admin” and password “admin” (or the password you have changed before) as shown in Figure 5-2.
Default IP Address: 192.168.0.100
Default User Name: admin
Default Password: admin
The following web screen is based on the IGS-10020MT; the display of the IGS-
10020MT is the same as that of the IGS-12040MT, IGS-10080MFT and IGS-20040MT.
After entering the password, the main screen appears as shown in Figure
5-3.
The Switch Menu on the top of the Web page lets you access all the commands
and statistics the Industrial L2+ Managed Switch provides.
The Switch Menu always contains one or more buttons, such as “System”,
“Switching”, “QoS”, “Security”, “Ring”, “ONVIF” and “Maintenance”.
If you are not familiar with Switch functions or the Note related parameter,
press “Help icon” anytime on the Web page to get the help description.
Now, you can use the Web management interface to continue the Switch
management or manage the Switch by console interface. Please refer to the
user’s manual for more details.
5.2 Saving Configuration
To save all applied changes and set the current configuration as a startup
configuration on the Web user interface, the startup configuration file will
be loaded automatically across a system reboot.
-
Click the Save icon on the top Switch Menu bar.
-
Press the “Save Configuration” button.
-
Or the other way to save the setting is to Click Maintenance, Save Startup Config.
Recovering Back to Default Configuration
To reset the IP address to the default IP address “192.168.0.100” and the user password to factory default mode (default password is admin), press the hardware-based reset button on the front panel for about 10 seconds. After the device is rebooted, you can log in the management Web interface within the same subnet of 192.168.0.xx and default password. Be noted that all the previous setups will be disappeared after the factory default reset is made.
Figure 6-1: IGS-10020MT Reset Button
Product Note
- IGS-10080MFT
The Port 3 and port 4 of IGS-10080MFT supports operating speeds of 100M, 1Gbps and 2.5Gbps. The table below shows physical port mapping to command line interface:
Port | CLI Interface |
---|---|
Port-1 | GigabitEthernet 1/1 |
Port-2 | GigabitEthernet 1/2 |
Port-3 | 2.5GigabitEthernet 1/1 |
Port-4 | 2.5GigabitEthernet 1/2 |
Port-5 | GigabitEthernet 1/3 |
Port-6 | GigabitEthernet 1/4 |
Port-7 | GigabitEthernet 1/5 |
Port-8 | GigabitEthernet 1/6 |
Port-9 | GigabitEthernet 1/7 |
Port-10 | GigabitEthernet 1/8 |
Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ
resource on PLANET web site first to check if it could solve your issue. If
you need more support information, please contact PLANET switch support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq
Switch support team mail address:
support@planet.com.tw
IGS-10020MT/IGS-10080MFT/IGS-12040MT/IGS-20040MT User’s Manual:
https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=IGS&view=3#list
(Please select your switch model name from the Product Model dropdown menu.)
Copyright © PLANET Technology Corp. 2022.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>