Overview
SIP-T20 is a IP based paging adapter that can covert analog to SIP. It’s small and portable design with black outlook. The various interfaces (MIC, headset and speaker) make it possible for quickly configure intercom and paging solution. It’s compatible with SIP & ONVIF protocol that can be used in VoIP and security field. It supports two-way intercom communication. Flexible Alarm in and out solutions( GPIO, HTTP URL, and relay out) are widely applied in daily life. The 48K OPUS Audio Codec enables excellent sound quality to make announcement, play background music, security alarm in school, factory and hospital, etc.
Interface Description
**** ① K1 DSS Key| Connect to:
1. external keys
2. infrared probe and emergency switch
3. door sensor and other switch components
---|---
**** ② K2 DSS Key| Connect to:
1. external keys
2. infrared probe and emergency switch
3. door sensor and other switch components
③ Relay NO COM Interface| Control the alarm system on/off
**** ④ IO Onput Interface| Responding to:
1.control the external amplifier power switch 2.the short-circuit input interface
3. login device security page settings
4. control the alarm light, electric locks and other equipment
5. with the adjacent power port connection for external equipment
⑤Microphone Interface| 2.2K Ohm impedance electric condenser microphone is recommended.
⑥ Headset Interface
| Speaker audio line signal output impedance 32 Ohm, single ended output
voltage 1.2V, used for external headphones or amplifier.
⑦ Speaker Interface| Maximum support 15W speaker.
⑧ Ethernet Interface| WAN port, standard RJ45 interface, 10/ 100M
adaptive, support POE input.
⑨ Volume Control Key| This two keys is to adjust the volume of the device’s,
bell, phone call and broadcasting, etc.
---|---
⑩ System Reset Key| Press Rest key and hold for 3 seconds, the devices
will restart to factory setting.
⑪ Run Indicator| The light is on shows that the device is working well.
⑫ Power Indicator| The light on shows that the power is connected.
⑬ Power Input Interface| 12V ~ 24V 2A input, according to the input voltage to
determine the maximum output power amplifier.
Web Configuration
Web configuration includes complete function setting. When the device and your computer are connected to a same network, please open a browser and type in http://192.168.5.200, then log in with defaulted username and password as below. Username: admin Password: tm1234
Status
You can check out firmware version, free space and two SIP accounts status of
SIP-T20, also can locate the current network information here, like MAC, IP
address and gateway etc.
Basic
-
* **Date/ Time**
There are two update modes for time:NTP/ local time, choose one and set the time zones, NTP sever and interval can choose default setting, then save the configuration.
-
Network
When you choose DHCP and save it, IP address will be created automatically by a DHCP server, then you need to login again with the new IP address on browser: 192.168.5.XXX.
Status IP address: it is a default IP and will not be changed as following.
ONVIF
Select Enable ONVIF, then the device be searched by ONVIF VMS. Default user
name: admin, password:tm1234.
SIP Account
Each device has two SIP accounts, put SIP extension messages into the blanks
and save the configuration, then you can check if it registers successfully or
not on status.
Expire time | Set the expire time of registered account information |
---|---|
Ringing tone | 5 system ringtones and 10 users upload media files |
Auto Answer | answer immediately and answer delay when a calling incomes |
Audio
- ACE(acoustic echo canceling): to make a perfect sound quality.
- Mic / out volume: adjust mic and output volume at 0-100.
- Jitter buffer: to make the audio more stable.
- Amp auto off: It’s set defaulted as ON, then there is no noise when not broadcasting.
- Code setting: four audio codes to compatible with major audio sources.
Media File
There are five system ringtones, and you can upload 10 media files as
customers’ demands: music, announcement, bells, etc.
Alarm
We can set 2 DSS keys and 2 SIP accounts to realize alarm function, to ready
the combination with alarm system.
-
DSS Key Setting
- Enable the file, you select a action type(start/ stop), play file and cycle mode, save the configuration, then press buttonK1 & K2, the bell will ring/close.
- SIP enable: choose a SIP account you register, SIP action: call out/hang up, you can put the SIP number, eg: 8112,make sure it’s the extensions which connected to the same IP sever with SIP account 1&2. If you select call out, and press K1/K2 button, then extension 8112 will receive a call.
- Enable URL: put the HTTP URL, after pressed K1/K2, the URL will be working.
- Output enable: turn on/off the output, press K1/K2, the output succeeds.
- Relay enable: turn on/off the output, press K1/K2, the relay succeed.
HTTP URL
User can control the alarm by HTTP URL:
- Enable the selection;
- Open any browser you have in computer;
- Put the URL as the following examples, enter it.
Schedule
This function is widely use in school, factory and office projects. Making a
regular bell, announcement and alarm. Enable the schedule, you can name the
schedule. then setting it step by step.
RTP Multicast IP
There are 10 RTP addresses can be received for each device, please note that:
port numbers do not use continuous numbers when setting the same RTP
addresses. Use discontinuous numbers. eg:
239.255.1.2:8000,239.255.0.1:8001,239.255.0.1:8002(×)
239.255.0.1:8000,239.255.0.1:8002,239.255.0.1:8004 (√)
- Multicast address range: 224.0.0.0-239.255.255.
- Ports range: 1024-65536
- Use IP Tool, Audio manager and PA System to make RTP multicast.
Firewall
This function is use to protect your network safety. You can edit the firewall
automatic defence rules as you need as follows.
System
- Upgrade
When reboot and reset the system, system will turn to original setting, and you need to re-login the web page.
How to upgrade SIP-T20 firmware version in web interface?
- Select the latest version firmware T20-xxx-bin.
- Click upgrade to refresh, it would require about 20s.
- Re-login the web interface, latest version has upgraded.
- Security
Set a new user name and password as you need, save the configuration and restart login.
IPTool Configuration
Apart from Web configuration, IPTool is the other option that configure quickly basic information such as SIP account setting, volume setting, RTP Multicast setting, upgrade. Please follow below steps.
- Download IPTool in https://www.tonmind.com/category/downloads/5
- Enter IPTool, scan local network, the device will appear and then start setting.