PPI UniLog Pro Temperature Data Logger Instruction Manual
- June 11, 2024
- PPI
Table of Contents
UniLog Pro / UniLog Pro Plus with CIM
Universal Process Data Recorder PC Software Version
UniLog Pro Temperature Data Logger
Operation Manual
This brief manual is primarily meant for quick reference to wiring connections
and parameter searching. For more details on operation and application; please
log on to www.ppiindia.net
OPERATOR PARAMETERS
Parameters| Settings (Default Value)
‘Start’ Command for Batch Recording
(Available if Batch Recording is selected)
| No Yes
BATCH START>> NO|
‘Stop’ Command for Batch Recording (Available if Batch Recording is
selected)| **** No Yes
BATCH STOP>> NO|
SUPERVISORY CONFIGURATION
Note: AII the other Parameters are under SUPERVISORY CONFIGURATION
ALARM SETTING
Parameters| Settings (Default Value)
Channel Name for Alarm Settings
SELECT CHANNEL>>
Channel-1
| User defined or default names for channel-1 to channel-8 / 16 (Default : NA)
Select Alarm
SELECT ALARM>> AL1
| AL1, AL2, AL3, AL4
(The actual available options depends on the numbers of Alarms set per channel on
Alarm configuration page)
Alarm Type
AL 1 TYPE>> None
| None Process Low Precess High (Default : None)
Alarm Setpoint
AL 1 SETPOINT>> 0
| Min. to Max. of selected input type range (Default : 0)
Alarm Hysteresis
AL 1 HYSTERESIS>> 2
| 1 to 3000 or
0.1 to 3000.0
(Default : 2 or 2.0)
Alarm Inhibit
AL 1 INHIBIT>> Yes
| No Yes
(Default : No)
DEVICE CONFIGURATION
Parameters| Settings (Default Value)
Channel Update Time in Auto Scan Mode
SCAN RATE>>
3
| ****
1 Sec. to 99 Sec. (Default : 3 Sec.)
Device Identification Number
RECORDER ID>>
2
| ****
1 to127
(Default : 1)
Select Total Numbers of Channels
TOTAL CHANNELS>>
16
| 8
16
(Default : 16)
Erase All Stored Records
DELETE RECORDS>>
No
| ****
No Yes
(Default : No)
CHANNEL CONFIGURATION
Parameters| Settings (Default Value)
Select Channel Name
SELECT CHANNEL>> Channel-1
| User defined or default names for channel-1 to channel – 8 / 16
(Default : NA)
Skip Channel for Display
SKIP>> No
| No Yes
(Default : Yes)
Signal Input Type
INPUT TYPE>> Type K (Cr-Al)
| Refer Table 2 (Default : Type K (Cr-Al)
Display Resolution for Measured PV
RESOLUTION>> 0.1 Unit
| 1 Unit
0.1 Unit
0.01 Unit *
0.001 Unit * (Default : 0.1 Unit)
(* for 4-20mA)
Display Units for Measured PV
UNITS>> °C
| ****
Refer Table 1 (Default : °C)
Range Low (for 4-20mA) RANGE LOW>> 0| -19999 to 30000 Counts with
Selected Resolution (Default : 0.0)
Range High
(for 4-20mA) RANGE HIGH>> 1000
| -19999 to 30000 Counts with Selected Resolution (Default : 100.0)
Apply Lower Clip on Displayed PV
(for 4-20mA) LOW CLIPPING>> Disable
| ****
Disable Enable
(Default : Disable)
Preset Lower Clip Level
(for 4-20mA) LOW CLIP VAL>> 0.0
| ****
-19999 to 30000
(Default : 0)
Apply Upper Clip on Displayed PV
(for 4-20mA) HIGH CLIPPING>> Disable
| ****
Disable Enable
(Default : Disable)
Preset Upper Clip Level
(for 4-20mA) HIGH CLIP VAL>> 100.0
| ****
-19999 to 30000
(Default : 100.0)
Zero Offset
ZERO OFFSET>> 0
| -1999 / 3000 or
-1999.9 / 3000.0
(Default : 0)
ALARM CONFIGURATION
Parameters| Settings (Default Value)
Alarms Per Channel
ALARMS / CHAN >> 4
| 1 to 4
(Default : 4)
Relay-1 Logic
RELAY-1 LOGIC >> Normal
| Normal Reverse (Default : Normal)
Relay-2 Logic
RELAY-2 LOGIC >> Normal
| Normal Reverse (Default : Normal)
RECORDER CONFIGURATION
Parameters| Settings (Default Value)
Normal Recording Interval
NORMAL INTERVAL>> 0:00:30
| 0:00:00 (H:MM:SS)
to 2:30:00 (H:MM:SS)
(Default : 0:00:30)
Zoom Recording Interval
ZOOM INTERVAL>> 0:00:01
| 0:00:00 (H:MM:SS)
to 2:30:00 (H:MM:SS)
(Default : 0:00:01)
Record Generation on Alarm Status Toggle
ALARM TOGGLE REC>> Disable
| ****
Disable Enable
(Default : Enable)
Select Recording Mode
RECORDING MODE>> Continuous
| Continuous Batch
(Default : Continuous)
Time Interval for Batch Recording (for Batch mode only)
BATCH TIME>> 1.00
| 0:01 (HH:MM)
to 250:00 (HHH:MM)
(Default : 1:00)
RTC SETTING
Parameters| Settings
Set Clock Time (HH:MM)
TIME (HH:MM)>>
15:53
| ****
0.0 to 23:59
Set Calendar Date
DATE>> 23
| ****
1 to 31
Set Calendar Month
MONTH>> 11
| ****
1 to 12
Set Calendar Year
YEAR>> 2011
| ****
2000 to 2099
UTILITIES
Parameters| Settings
Master Lock Enable Disable
LOCK>> No UNLOCK>> No
| ****
No Yes
UIM Default
UIM DEFAULT>> No
| No Yes
CIM Default
CIM DEFAULT>> No
| ** No Yes
Make CIM & UIM Compatible**
CPY CIM TO UIM>> No CPY UIM TO CIM>> No
| No Yes
TABLE- 1
Option| Description
°C| Degree Centigrade
°F| Degree Fahrenheit
(none)| No Unit (Blank)
°K| Degree Kelvin
EU| Engineering Units
%| Percentage
Pa| Pascals
Mpa| Mpascals
kPa| Kpascals
bar| Bar
mbar| Milli bar
psi| PSI
kg/sq.cm| kg/cm 2
mmH2O| mm water gauge
inH2O| Inches water gauge
mmHg| mm mercury
Torr| Torr
litre/hr| Litres per hour
litre/min| Litres per minute
%RH| % Relative Humidity
%O2| % Oxygen
%CO2| % Carbon di-oxide
%CP| % Carbon Potential
V| Volts
A| Amps
mA| Milli Amps
mV| Milli Volts
ohm| Ohms
ppm| Parts per million
rpm| Revolutions per minute
mSec| Milli seconds
Sec| Seconds
min| Minutes
hrs| Hours
PH| PH
%PH| %PH
miles/hr| Miles per hour
mg| Milli grams
g| Grams
kg| Kilo grams
TABLE- 2
Option| Range (Min. to Max.)| Resolution
| ****
0 to +960°C / +32 to +1760°F
| ****
Fixed 1°C / 1°F
|
|
| ****
0 to +1771°C / +32.0 to +3219°F
| ****
0 to +1768°C / +32 to +3214°F
|
|
| Reserved for customer specific Thermocouple type not listed above.
| -199 to +600°C / -328 to +1112°F
– 199.9 to or to 1112.0°F
600.0°C / -328.0
| User settable 1°C / 1°F
or 0.1°C / 0.1°F
| 19999 to +30000 units| User settable 1 / 0.1 / 0.01/
0.001 unts
ID SETTING FOR MORE THAN 1 CIM
Applicable only for UNILOG PRO PLUS
FRONT PANEL LAYOUT
Symbol
| Key| Function
---|---|---
| PAGE| Press to enter or exit set-up mode.
| ****
DOWN
| Press to decrease the parameter value. Pressing once decreases the value by
one count; holding pressed speeds up the change.
| ****
UP
| Press to increase the parameter value. Pressing once increases the value by
one count; holding pressed speeds up the change.
| ENTER| Press to store the set parameter value and to scroll to the next
parameter on the PAGE.
ELECTRICAL CONNECTIONS
USER INTERFACE MODULE (UIM)
COMMUNICATION PORT FOR INTERFACING WITH CIM(S)
Applicable only for UNILOG PLUS
JUMPER SETTINGS
INPUT-CHANNEL INTERFACE MODULE (CIM)![PPI UniLog Pro Temperature Data Logger
- fig 14](https://manuals.plus/wp-content/uploads/2023/05/PPI-UniLog-Pro- Temperature-Data-Logger-fig-14.jpg)
JUMPER SETTINGS
INPUT-CHANNEL INTERFACE MODULE (CIM)![PPI UniLog Pro Temperature Data Logger
- fig 25](https://manuals.plus/wp-content/uploads/2023/05/PPI-UniLog-Pro- Temperature-Data-Logger-fig-25.jpg)
ELECTRICAL CONNECTIONS
CHANNEL INTERFACE MODULE (CIM)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>