INSTRUCTION
UNPACKING
After purchasing the product, check the contents of the package and the
technical condition of the heating mat.
When purchasing a heating mat installation kit, the package includes:
- heating mat
- thermostat with a floor temperature sensor
- protective tube of the power cord (conduit)
- installation box
- protective tube of the temperature sensor (conduit)
SAFETY
TTENTION! PLEASE READ THE MANUAL FOR USING THE HEATING MAT BEFORE STARTING THE OPERATION AND KEEP THE MANUAL FOR FUTURE REFERENCE.
- It is possible to use the heating film by children from 8 years of age, provided that supervision and proper instruction on safe operation are provided.
- Children under eight years old should not play with the thermostat.
- Children are not allowed to perform cleaning and maintenance activities on the equipment without parental supervision. All activities related to the maintenance and cleaning of the equipment must be carried out in a safe manner and with the power o.
- This installation may be operated by people with reduced physical or mental capabilities who have no previous experience with the product, but have received instructional training in how to use the installation in a safe manner.
- If the power cord or the heating mat is damaged, the product is not suitable for use and installation and should be disposed of.
- Installation of underfloor heating and Heat Decor heating mat must have a separate electric circuit, type B overcurrent switch and dierential-current switch. The types of circuit breakers and residual current devices are selected by an electrical designer or licensed electrician.
ATTENTION! IF THE HEAT DECOR HEATING MAT IS DAMAGED DURING UNPACKING, IT IS FORBIDDEN TO BE INSTALLED AND IT IS RECOMMENDED TO CONTACT THE SELLER.
PRODUCT DESCRIPTION
The Heat Decor heating mat is intended for the installation of underfloor heating in rooms inside the building. The heating mat is suitable for underfloor heating with the use of floor coverings such as ceramic, porcelain and stone tiles. The heating mat is suitable for installation in thin, flexible adhesive layers, the thickness of which does not exceed 1.5 cm.
The heating mat consists of three elements:
- heating wire (blue)
- self-adhesive backing mesh made of glass fiber
- electric power cord, three-pole (Pic. No. I.)
TECHNICAL DATA
LP | NAME | DATA |
---|---|---|
1 | Supply voltage | 230V +/- 10% 50/60 Hz |
2 | The width of the mat | 50 cm |
3 | Mat length | area sqm x2 |
4 | Heating power | 150 W/sqm |
5 | Heating core insulation | FEP |
6 | External insulation | FEP |
7 | Degree of protection | IPX7 |
8 | Power supply | One-sided |
9 | Load-bearing substrate – the net itself adheres sticky |
fiberglass – white
10| Cable length power supply| 2.5 rm
PREPARING FOR INSTALLATION
Before installation, it is necessary to check the resistance of the heating mat. Use an electric meter – multimeter to measure resistance. Perform the resistance measurement on the blue and brown heating mat power wires. The resistance is expressed in units of Ohm (OM). Due to dierent meters and measurement conditions, the result may deviate from the norm by +/- 5%. (Pic. No. I.)
ATTENTION! IF THE MEASUREMENT RESULTS SIGNIFICANTLY DIFFERENT FROM THE VALUES SHOWN IN THE TABLE BELOW, CONTACT THE SELLER AND DO NOT INSTALL THE HEATING MAT.
HEATING MAT HD-mat 150
**** MODEL| POWER [W]| DIMENSION[m*m]| AREA[sqm]|
WIRE LENGTH[rm]| ** RESISTANCE [Ω]
---|---|---|---|---|---
HD-mat 150/1.0| 150| 0,52| 1,0| 12,50| 352,7
HD-mat 150/1.5| 225| 0,53| 1,5| 18,75| 235,1
HD-mat 150/2.0| 300| 0,54| 2,0| 25,00| 176,3
HD-mat 150/2.5| 375| 0,55| 2,5| 31,25| 141,1
HD-mat 150/3.0| 450| 0,56| 3,0| 37,50| 117,6
HD-mat 150/3.5| 525| 0,57| 3,5| 43,75| 100,8
HD-mat 150/4.0| 600| 0,58| 4,0| 50,00| 88,2
HD-mat 150/4.5| 675| 0,59| 4,5| 56,25| 78,4
HD-mat 150/5.0| 750| 0,510| 5,0| 62,50| 70,5
HD-mat 150/6.0| 900| 0,512| 6,0| 75,00| 58,8
HD-mat 150/7.0| 1050| 0,514| 7,0| 87,50| 50,4
HD-mat 150/8.0| 1200| 0,516| 8,0| 100,00| 44,1
HD-mat 150/9.0| 1350| 0,518| 9,0| 112,50| 39,2
HD-mat 150/10.0| 1500| 0,520| 10,0| 125,00|
35,3
HD-mat 150/12.0| 1800| 0,5*24| 12,0| 150,00|
29,4**
HEATING MAT INSTALLATION PROJECT
Preparation of the heating mat installation design greatly facilitates the installation of underfloor heating and allows the heating mat to be adapted to the prevailing conditions in the room. The prepared project is also an important document for the user during the operation of the heating mat. In the design of the heating mat installation, draw the mat on the floor, mark the installation site for the installation box with the power supply line, the floor sensor and the heating mat power lines. On the basis of the completed project, use chalk or pencil to draw all elements of the planned installation in the room.
Elements of the heating system:
- Heating mat
- Floor temperature sensor in a conduit
- Temperature controller
Assembly rules included in the design:
A. The floor temperature sensor is placed in a protective conduit, which
is led into previously prepared hole in the floor. The conduit runs parallel
to the heating cables. Place the end of the conduit with the temperature
sensor in the middle of the width of the heating mat.
B. Correct change of direction of the heating mat is related to cutting
the underlying mesh.
C. Keep a safe distance of the heating mat from the fixed furniture.
D. Keep a safe distance of the heating mat from the bathroom fittings.
E. Keep a safe distance from the heating mat to the wall.
F. Keep a safe distance between the heating cables.
ILLUSTRATIVE SECTIONS OF THE INSTALLATION
(PIC. NO. III.)
- Power line ~ 230 V
- Temperature controller
- A conduit with power cables for the heating mat
- Pipe with floor sensor
- Heating mat
- Thermal insulation of the floor (optional)
- Flexible adhesive mortar
- Underlay (screed)
- Tiles
- Flexible adhesive
- Conduit end with floor sensor
(PIC. NO. IV.)
Temperature controller and conduit with floor temperature sensor can be
carried out in two ways:
A. The temperature controller is located outside the bathroom, and the
conduit with the sensor is led in the external wall. The conduit with the
floor temperature sensor is led to the heating mat through a hole in the wall.
B. The regulator is placed inside the bathroom and the conduit with the
floor temperature sensor is led in a channel cut into the wall and in the
floor.
- Temperature controller
- Installation box
- Wall
- Conduit with power cables from the heating mat
- Wall glaze
- Floor sensor tube
- Tiles
- Heating mat
- Adhesive layer
- Underlay (screed)
HEATING MAT INSTALLATION
ASSEMBLY RULES
- Take special precautions when installing the heating mat so as not to damage it.
- The heating mat may only be installed by a qualified installer. All electrical connections are made by a licensed electrician.
- Before the installation of the heating mat assembly, during its assembly and completion of assembly, the resistance (including insulation) should be tested with a multimeter in order to detect any damage to the heating mat. The permissible tolerance of the mat resistance results is + 10%/-5%.
- The heating mat must be installed only on horizontal floors. It is forbidden to install the heating mat on ceilings and walls.
- The heating cables must not be cut. Only the glass fiber mesh backing may be cut. It is forbidden to shorten, crush or cut the mat’s heating cables.
- The heating mat should have a separate power supply and should not be connected to other heat sources or other electrical devices.
- The heating mats may only be connected to the power supply in a parallel manner. Connection in series is forbidden because it leads to a decrease in power of the heating mat.
- The heating mats are intended for underfloor heating, which can only be finished with ceramic, porcelain or stone tiles. It is forbidden to use heating mats under wooden floors, laminated panels and vinyl panels.
- All materials used for the floor covering must have a thermal resistance up to 80°C. Do not use floor finishes that could become distorted or cracked due to heat transfer.
- Thermal insulation of the floor used directly under the heating mat must have a thermal resistance of min. 80°C and compressive strength min. 300kPa.
- The substrate on which the heating mat will be installed must be flat, cleaned, even and primed with a primer.
- When installing the heating mat on insulating bases, the base must be flat, sanded, cleaned and primed.
- The heating mat may be powered only in a installation box, it is forbidden to power the heating mat directly from a socket.
- It is forbidden to install the heating mat without a temperature regulator (thermostat) equipped with a floor temperature sensor.
- The heating mat must be equipped with an RCD switch and a B type overcurrent switch in its circuit.
- The heating cables must not overlap or touch each other. It is forbidden to fix the heating mat with nails, screws, bolts and other metal objects.
- The place of installation of the heating mat must be dry. The heating mat should be protected against direct access and action of water and moisture.
- It is forbidden to use the heating mat in the 0 and 1 anti-shock zones.
- It is forbidden to install heating mats under permanent furniture, which directly adheres to the floor and prevents the free flow of heat.
- When installing the heating mat in bathrooms, leave free space for the installation of sanitary facilities such as a bathtub, toilet bowl, shower, shower tray, etc.
- Unheated stripes 5-10 cm wide should be left along the walls.
- The installation design should take into account unheated zones.
- During assembly, use only shoes with flat and rubber soles and avoid walking on heating wires.
- Flexible adhesives and materials intended for underfloor heating should be used for the installation of the heating mat and floor coverings.
- All installation works should be performed with the main electric power switched o.
- After the assembly works are completed in the place where the heating mat is installed, drilling, forging and other activities that may damage the heating system are prohibited.
- It is forbidden to install the heating mat at a temperature below 5°C.
- When performing the installation, observe all dimensions and distances specified in the manual.
- The instructions, together with the completed warranty card and the precisely prepared design, should be kept for further users and future installation and maintenance works.
PREPARATION OF THE ROOM FOR INSTALLATION
In the designated place according to the design, use a drill or hole saw to
drill a hole for the Ø 60 installation box. Cut an installation channel in the
wall and floor to accommodate the conduit for the floor temperature sensor and
the conduit for the heating mat power wires. In the place of the installation
box, lead the electric lines powering the heating mat. The power cord cross-
section is selected by a licensed electrician or designer.
A. Installation channel
Embed the conduit of the floor sensor in the installation channel. Insert the
floor sensor into the conduit up to the end of the covered tube.
Place the conduit with the floor temperature sensor inside the installation
box.
Insert the main power supply line and the conduit with the floor temperature
sensor into the installation box. Cut the end of the tube to an appropriate
length for the installation of the thermostat.
PLACING THE HEATING MAT ON THE FLOOR
The heating mat is assembled on a self-adhesive glass fiber mesh. Before
sticking, the heating mat should be straightened. The heating mat must be
evenly glued to the prepared floor in accordance with the previously prepared
installation design.
The floor temperature sensor, installed in the conduit, must be positioned
equidistant between two adjacent sections of the heating mat cable.
IF THE HEATING MAT NEEDS TO BE WRAPPED ON THE FLOOR, THIS CAN BE DONE IN THREE
WAYS:
LAYING A HEATING MAT ON THE FLOOR
After laying the heating mat, insert the power cables of the heating mat into
the conduit. Place the conduit with the power cord in the previously prepared
installation channel and put it into the installation box. Cut the conduit
with the power cord to a suitable length for the correct installation of the
temperature controller.
Perform a control measurement of the heating mat resistance.
SEALING THE MAT
Apply an evenly flexible adhesive mortar intended for underfloor heating with
a plastic trowel on a properly distributed heating mat. The mortar should be
spread very carefully over the entire surface, carefully covering the heating
cables. Properly glued heating mat should be left to dry for 24 hours. After
24h, check the resistance of the heating mat again.
LAYING A HEATING MAT ON THE FLOOR
After laying the heating mat, insert the power cables of the heating mat into
the conduit. Place the conduit with the power cord in the previously prepared
installation channel and put it into the installation box. Cut the conduit
with the power cord to a suitable length for the correct installation of the
temperature controller
After laying the tiles and hardening the glue, make the final measurement of
the resistance of the heating mat. Write down the measurement result in the
warranty card.
CONNECTING THE HEATING MAT TO THE THERMOSTAT
Install the temperature controller in the prepared installation box with the
wires for powering the heating mat, the power line wires and the wire from the
floor temperature sensor. Install the thermostat in accordance with the
instructions provided by the thermostat manufacturer.
THE HEATING MATE CAN BE CONNECTED TO THE THERMOSTAT IN TWO WAYS:
A GROUND WIRE CONNECTED TO THE THERMOSTAT
B GROUND WIRE OUTSIDE THE THERMOSTAT
FIRST START OF THE HEATING
After 14 days from the installation of the tiles, the underfloor heating can
be started, provided that a constant temperature of min. 18°C. If the room
temperature was below 18°C, the first heating start period will be extended.
The first set temperature of the floor in the heating process should not
exceed 19 degrees, this is due to the need to loosen the adhesive layer.
Within three days, this temperature can be gradually increased to a maximum
temperature of 25°C.
WARRANTY CARD
The warranty does not cover:
- Mechanical damage to the heating film.
- Damage to the heating film as a result of fire, flood, lightning strike.
- Damage to the heating film resulting from the installation of the heating film not following the instructions contained or improper use.
- Damage to the heating film or malfunction of the heating system resulting from the use of materials inconsistent with the manufacturer’s recommendations and assembly instructions.
DATA
Buyer|
Heating mat installer (stamp)|
HEATING MAT INSTALLATION DATA
Installation date|
Model & power of the heating mat|
Measurement of the resistance of the heating mat [Ω] (1)|
Measurement of the resistance of the heating mat [Ω] (2)|
Measurement of the resistance of the heating mat [Ω] (3)|
Required attachments:
- Sketch of heating mat installation
- Protocol of receipt of the heating mat installation
- Proof of purchase of the heating mat
Heat Decor Sp z o.o.
54 Gromadzka St., 30-719 Cracow / Poland
www.heatdecor.com/en/
info@heatdecor.com, tel: (+48) 123 576 134