HEAT DECOR HD-T01 Thermostat
Product Information
Specifications
- Accuracy : 16 A
- Floor temperature range : 230 V
- Maximum load: IP21
- Power supply: 86 x 86 x 22 mm
- IP Rating: IP21
- Front panel dimensions: 86 x 86 x 22 mm
Product Usage Instructions
Preparation for Installation
- Turn off the power supply from the electrical panel.
- Set the control knob to the minimum temperature setting, and slightly raise it.
Installation of the External Floor Temperature Sensor
- The external floor temperature sensor should be placed in a separate installation conduit that is run from the thermostat to the floor.
- To ensure the thermostat operates correctly, the external floor temperature sensor must be positioned in the location specified by the heating device’s installation instructions.
Thermostat Installation
- Perform the installation with the power supply turned off from the electrical panel.
- Connect the wires as shown in the diagram below.
Control of the Thermostat
The LED indicator will light up in red when the heating is turned on.
HD-T01 thermostat description
- Electronic manual thermostat designed to control electric heating devices. It has one external floor temperature sensor.
- Manual electronic thermostat designed for controlling electric heating devices and for installation exclusively inside a building. It has one external floor temperature sensor. The set floor temperature determines the level to which the air in the room will gradually approach, but it is not directly equivalent to it. The temperature on the thermostat should be adjusted to achieve the desired thermal comfort in the specific room.
- The activated heating system is indicated by an LED indicator.
Technical specification
- Accuracy ± 5°C
- Floor temperature range 5°C – 40°C
- Maximum load 16 A
- Power supply 230 V
- IP Rating IP21
- Front panel dimensions 86 x 86 x 22 mm
Preparation for installation
- Thermostat
- Installation box
- Protective conduit
- External floor temperature sensor
Installation of the external floor temperature sensor
- The external floor temperature sensor should be placed in a separate installation conduit that is run from the thermostat to the floor.
- To ensure the thermostat operates correctly, the external floor temperature sensor must be positioned in the location specified by the heating device’s installation instructions.
Thermostat installation
- Perform the installation with the power turned off.
- Set the temperature control knob to the minimum temperature position, gently pry it open and remove it, then unscrew the front of the thermo-stat from the mounting plate. Screw D attaches the front panel to the mounting plate. Screw C limits the temperature range.
- Connect the wires as shown in the diagram below.
- Mount and tighten the mounting plate in a standard installation box with a diameter of Ø 60 mm.
- Tighten the front of the thermostat to the mounting plate, then gently press the control knob in the minimum temperature position.
Thermostat installation
The complete set of components that make up the HD-T01 thermostat
The thermostat should be installed by an experienced electrician with appropriate qualifications.
NOTES : The set floor temperature must not exceed the temperature limits specified by the flooring manufacturer.
Thermostat control
- The thermostat has a temperature adjustment range for the floor of 5 – 40°C. To make temperature regulation more convenient, the thermostat is equipped with an LED indicator that will light up in red when the heating is turned on.
- After turning on the thermostat and setting the desired floor temperature using the dial, the LED indicator will continue to light up until the set floor temperature is reached.
- Limiting the maximum temperature: the mechanism for locking the temperature control range (of the control knob) is located behind the control knob. The control knob should be set to the minimum temperature position and gently pried open. With the small screw located underneath it on the right side, the temperature range can be locked, for example, between 20°C and 25°C.
Floor sensor – temperature
Compliance with regulations
- The device is CE-certified. The device complies with the following European Union directives: Directive 2014/30/EU on electromag-netic compatibility; Low Voltage Directive 2014/35/EU.
- The device has been certified with a safety mark indicating it is safe for use.
- The device complies with the European Parliament and Council Directive RoHS (Restriction of Hazardous Substances) (2011/65/EU). It does not contain harmful and prohibited substances listed in this directive.
- This symbol signifies the obligation of selective waste collection within the European Union. It is prohibited to dispose of the used equipment together with other household waste. Failure to comply with selective waste collection can have potentially negative effects on the environment and human health due to the presence of hazardous components in the equipment. Households play a crucial role in contributing to reuse and recovery, including the recycling of used electrical and electronic equipment.
Disassembled or dismantled equipment should be delivered to a Selective Municipal Waste Collection Point. The owner of used equip-ment from households is obligated to deliver it to the following entities:
- retail establishments with an area exceeding 400 m2 (for used equip-ment with dimensions not exceeding 25 cm, there is no requirement to purchase new equipment),
- processing facilities,
- collection points for used electrical and electronic equipment.
The seller in Poland is required to accept, free of charge, used equipment from households at the point of sale, provided that the used equipment is of the same type and performs the same functions as the equipment being sold. The seller accepts the used equipment at the following address: Heat Decor sp. z o.o., ul. Gromadzka 54, 30-719 Kraków, Poland. The seller in Poland, when delivering equipment intended for house-holds to the customer, is obliged to accept, free of charge, used equip-ment from households at the place of delivery of that equipment, provided that the used equipment is of the same type and performs the same functions as the equipment being delivered. In accordance with Article 2, point 19 of the Act of March 27, 2003, on spatial planning and development (Polish Journal of Laws of 2018, item 1945, as amended), the seller operating a retail trade establishment in Poland with a sales area (as defined in the mentioned artic-le) of at least 400 m2 dedicated to the sale of equipment intended for households is obliged to accept, free of charge, used equipment from households at that establishment or in its immediate vicinity, provided that none of the external dimensions of the equipment exceeds 25 cm, without the obligation to purchase new equipment intended for households. The seller accepts the used equipment at the following address: Heat Decor sp. z o.o., ul. Gromadzka 54, 30-719 Kraków.
Watch our video tutorials and discover the latest innovations
FAQ
Is it necessary to hire a professional electrician to install the
thermostat?
Yes, it is recommended that the thermostat is installed by an experienced
electrician with current SEP qualifications.
What should be the maximum floor temperature setting?
The floor temperature should not exceed the maximum values specified by the
floor manufacturer.