TESLA TGZUJ Series Multi Split Type Air Conditioner User Manual
- June 9, 2024
- Tesla
Table of Contents
MULTI SPLIT-TYPE AIR CONDITIONER
USER MANUAL
For Indoor unit models:
TGZUJ-V07P4/TGZUJ-V09P4/TGZUJ-V12P4/
TGZUJ-V18P4/TGZUJ-V24P4
TGZUJ Series Multi Split Type Air Conditioner
OPERATING INSTRUCTION
Note: All the pictures in this manual are just schematic diagrams, the
actual is the standard. Please read this owner’s manual carefully and
thoroughly before operating the unit! Take care of this manual for future
reference.
WARNING
Warning: This air conditioner uses R32 flammable refrigerant.
Notes: Air conditioner with R32 refrigerant, if roughly treated, may
cause serious harm to the human body or surrounding things.
- The room space for the installation, use, repair, and storage of this air conditioner should be greater than 5 m’.
- Air conditioner refrigerant can not charge more than 1. 7kg.
- Do not use any methods to speed up defrost or to clean frosty parts except for particular recommended by manufacturer.
- Not pierce or burn air conditioner, and check the refrigerant pipeline wether be damaged.
- The air conditioner should be stored in a room without lasting fire source, for example, open flame, burning gas appliance, working electric heater and so on.
- Notice that the refrigerant may be tasteless.
- The storage of air conditioner should be able to prevent mechanical damage caused by accident.
- Maintenance or repair of air conditioners using R32 refrigerant must be carried out after security check to minimize risk of incidents.
- Air conditioner must be installed with stop valve cover.
- Please read the instruction carefully before installing, using and maintaining.
Symbol | Note | Explanation |
---|---|---|
WARNING | This symbol shows that this appliance uses a flammable |
refrigerant.If the refrigerant is leaked and exposed to an external ignition
source, there is a risk of fire.
****| CAUTION| This symbol shows that the operation manual should be read
carefully.
| CAUTION| This symbol shows that a service personnel should be handling this
equipment with reference to the installation manual.
| CAUTION| This symbol shows that information is available such as the
operating manual or installation manual.
SAFETY PRECAUTIONS
Incorrect installation or operation by not following these instructions may
cause harm or damage to people, properties, etc. The seriousness is classified
by the following indications:
WARNING!
This symbol indicates the possibility of death or serious injury.
CAUTION!
This symbol indicates the possibility of injury or damage to properties.
WARNING!
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (Only for the AC with CE-MARKING)
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. (Except for the AC with CE-MARKING)
-
**** The air conditioner must be grounded. Incomplete grounding may result in electric shocks. Do not connect the earth wire to the gas pipeline, water pipeline, lightning rod, or telephone earth wire.
-
Always switch off the device and cut the power supply when the unit is not in use for long time so as to ensure safety.
-
Take care not let the remote control and the indoor unit watered or being too wet. Otherwise, it may cause short circuit.
-
If the power supply cable is damaged, it must be replaced by manufacture or its service agent or a similar qualified person.
-
Don’t cut off main power switch during operating or with wet hands. It may cause electric shock.
-
Don’t share the socket with other electric appliance. Otherwise, it may cause electric shock even fire and explosion.
-
Always switch off the device and cut the power supply before performing any maintenance or cleaning. Otherwise, it may cause electric shock or damage.
-
Don’t pull the power cord when pull out the power plug. The damage of pulling power cord will cause serious electric shock.
-
A warning that ducts connected to an appliance shall not contain an ignition source.
-
Don’t install air conditioner in a place where there is flammable gas or liquid. The distance between them should above 1m. It may cause fire even explosion.
-
Don’t use liquid or corrosive cleaning agent wipe the air conditioner and sprinkle water or other liquid either.
Doing this may cause electric shock or damage to the unit. -
Don’t attempt to repair the air conditioner by yourself. Incorrect repairs may cause fire or explosion. Contact a qualified service technician for all service requirement.
-
Don’t use air conditioner in lightning strom weather. Power supply should be cut in time to prevent the occurrence of danger.
-
Don’t put hands or any objects into the air inlets or outlets. This may cause personal injury or damage to the unit.
-
Please note whether the installed stand is firm enough or not. If it is damaged, it may lead to the fall of the unit and cause the injury.
-
Don’t block air inlet or air outlet. Otherwise, the cooling or heating capacity will be weakened, even cause system stop operating.
-
Don’t let the air conditioner blow against the heater appliance. Otherwise it will lead to incomplete combustion, thus causing poisoning.
-
The appliance shall be installed in accordance with national wiring regulations.
-
An earth leakage breaker with rated capacity must be installed to avoid possible electric shocks.
-
This product contains fluorinated greenhouse gases.
-
Refrigerant leakage contributes to climate change.
Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [675]. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [675] times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. -
Ensure no following objects under the indoor unit:
1. microwaves, ovens and other hot objects.
2. computers and other high electrostatic appliances.
3. sockets that plug frequently. -
The joints between indoor and outdoor unit shall not be reused, unless after re-flaring the pipe.
-
The specification of the fuse are printed on the circuit bord, such as: 3.15A/250V AC, etc.
WEEE Warning
**** Meaning of crossed out wheeled dustbin: Do not dispose of electrical
appliances as unsorted municipal waste, use separate collection facilities.
Contact you local government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get into the food
chain, damaging yourhealth and well-being. When replacing old appliances with
new ones, the retailer is legally obligated to take back your old appliance
for disposals at least free of charge.
CAUTION!
- Don’t open the windows and doors for long time when the air conditioner is running. Otherwise, the cooling or heating capacity will be weakened.
- Don’t stand on the top of the outdoor unit or place heavy things on it. This cloud cause personal injuries or damage the unit.
- Don’t use the air conditioner for other purposes, such as drying clothes, preserving foods,etc.
- Don’t apply the cold air to the body for a long time. It will deteriorate your physical conditions and cause health problems.
- Set the suitable temperature. It is recommended that the temperature difference between indoor and outdoor temperature should not be too large. Appropriate adjustments of the setting temperature can prevent the waste of electricity.
- If your air conditioner is not fitted with a supply cord and a plug, an anti-explosion all-pole switch must be installed in the fixed wiring and the distance between contacts should be no less than 3.0 mm.
- If your air conditioner is permanently connected to the fixed wiring, a anti-explosion residual current device (RCD) having rated residual operating current not exceeding 30 mA should be installed in the fixed wiring.
- The power supply circuit should have leakage protector and air switch of which the capacity should be more than1 .5 times of the maximum current.
- Regarding the installation of the air conditioners, please refer to the below paragraphs in this manual.
NOTICES FOR USE
The conditions of unit can’t normally run
- Within the temperature range provided in following table, the air conditioner may stop running and other anomalies may arise.
Cooling| Outdoor| >43°C (Apply to T1)
52°C (Apply to T3)
---|---|---
Indoor| <18°C
Heating| Outdoor| >24°C
<-7°C
---|---|---
Indoor| >27°C
- When the temperature is too high, the air conditioner may activate the automatic protection device, so that the air conditioner could be shut down.
- When the temperature is too low, the heat exchanger of the air conditioner may freeze, leading to water dripping or other malfunction.
- In long-term cooling or dehumidification with a relative humidity of above 80% (doors and windows are open), there may be water condenses or dripping near the air outlet.
- T1 and T3 refer to ISO 5151.
Notes for heating
- The fan of the indoor unit will not start running immediately after the heating is started to avoid blowing out cool air.
- When it is cold and wet outside, the outdoor unit will develop frost over the heat exchanger which will increased the heating capacity. Then the air conditioner will start defrost function.
- During defrost, the air conditioner will stop heating for about 5-12 minutes.
- Vapor may come out from the outdoor unit during defrost. This is not a malfunction, but a result of fast defrost.
- Heating will resume after defrost is complete.
Notes for turning off
- When the air conditioner is turned off, the main controller will automatically decide whether to stop immediately or after running for dozens of seconds with lower frequency and lower air speed.
Emergency operation
- If the remote controller is lost or broken, use force switch button to operate the air conditioner.
- If this button is pushed with the unit OFF, the air conditioner will operate in Auto mode.
- If this button is pushed with the unit ON, the air conditioner will stop running.
Airflow direction adjustment
- Use up-down swing and left-right swing buttons on the remote controller to adjust the airflow direction. Refer to the operation manual of the remote controller for detail.
- For models without left-right swing function, the fins has to be moved manually.
Note: Move the fins before the unit is in operation, or your finger might be injured. Never place your hand into the air inlet or outlet when the air conditioner is in operation.
Specific caution
- Open front panel of the indoor.
- The connector (as Fig) can not touch the terminal board, and is positioned as shown in Fig.
NAMES OF EACH PART
Indoor unit
Outdoor unit
Note: All the pictures in this manual are just schematic diagrams, the
actual is the standard.
Plug, WiFi function, Negative-ion function, and vertical and horizontal; swing
function both are optional.
CLEAN AND CARE
WARNING!
- Before the cleaning of the air conditioner, it must be shut down and the electricity must be cut off for more than 5 minutes, otherwise there might be the risk of electric shocks.
- Do not wet the air conditioner, which can cause an electric shock. Make sure not to rinse the air conditioner with water under any circumstances.
- Volatile liquids such as thinner or gasoline will damage the air conditioner housing, therefore please clean the housing of air conditioner only with soft dry cloth and damp cloth moistened with neutral detergent.
- In the course of the using, pay attention to cleaning the filter regularly, to prevent the covering of dust which may affect the effect. If the service environment of the air conditioner is dusty, correspondingly increase the number of times of cleaning. After removing the filter, do not touch the fin part of the indoor unit with the finger, and no force to damage the refrigerant pipeline.
Clean the panel
When the panel of the indoor unit is contaminated, clean it gently with a
wrung towel using tepid water below
40°C, and do not remove the panel while cleaning.
Clean the air filter
Remove the air filter
- Use both hands to open the panel for an angle from both ends of the panel in accordance with the direction of the arrow.
- Release the air filter from the slot and remove it.
Clean the Air Filter
Use a vacuum cleaner or water to rinse filter, and if the filter is very dirty
(for example, with greasy dirt), clean it with warm water (below 45 °C) with
mild detergent dissolved in, and then put the filter in the shade to dry in
the air.
Mount the Filter
- Reinstall the dried filter in reverse order of removal, then cover and lock the panel.
Check before use
- Check whether all the air inlets and outlets of the units are unblocked.
- Ceck whether there is blocking in the water outlet of the drain pipe, and immediately clean it up if any.
- Check the ground wire is reliably grounded.
- Check whether the remote control batteries are installed, and whether the power is sufficient.
- Check whether there is damage in the mounting bracket of the outdoor unit, and if any, please contact our local service center.
Maintain after use
- Cut off the power source of the air conditioner, turn off the main power switch and remove the batteries from the remote controller.
- Clean the filter and the unit body.
- Remove the dust and debris from the outdoor unit.
- Check whether there is damage in the mounting bracket of the outdoor unit, and if any, please contact our local service center.
CAUTION!
Do not repair the air conditioner by yourself as wrong maintenance may
cause electric shock or fire or explode, please contact the authorized service
center and let the professionals conduct the maintenance, and checking the
following items prior to contacting for maintenance can save your time and
money.
TROUBLESHOOTING
Phenomenon | Troubleshooting |
---|---|
The air conditioner does not work. | • There might be power outages. → Wait |
until power is restored.
• Power plug may be loose out from the socket. → The plug in the plug
tightly.
• Power switch fuse may blow. → Replace the fuse.
• The time for timing boot is yet to come. → Wait or cancel the timer
settings.
The air conditioner can’t run after the immediate
start-up after it is shut down.| • If the air conditioner is turned on
immediately after it is turned off, the protective delay switch will delay the
operation for 3 to 5 minutes.
The air conditioner stopsrunning after it starts up for a while.| • May reach
the setting temperature. → It is a normal function phenomenon.
• May be at a defrosting state. → It will automatically restore and run again
after defrosting.
• Shutdown Timer may be set. → If you continue to use, please turn it on
again.
The wind blows out, but the cooling/ heating
effect is not good.| • Excessive accumulation of dust on filter, blocking at
air inlet and outlet, and the excessively small angle of the louver blades all
will affect the cooling and heating effect. → Please clean the filter,
remove the obstacles at the air inlet and outlet and regulate the angle of the
louver blades.
• Poor cooling and heating effect caused by doors and windows opening, and
unclosed exhaust fan. → Please close the doors, windows, the exhaust fan, etc.
• Auxiliary heating function is not turned on while heating, which may lead to
poor heating effect. → Turn on the auxiliary heating function. (only for
models with auxiliary heating function)
• Mode setting is incorrect, and the temperature and wind speed settings are
not appropriate. → Please re-select the mode, and set the appropriate
temperature and wind speed.
The indoor unit blows out odor.| • The air conditioner itself does not have
undesirable odor. If there is odor, it may be due to accumulation of the odor
in the environment. → Clean the air filter or activate the cleaning function.
There is sound of running water during the running of air conditioner.| • When
the air conditioner is started up or stopped, or the compressor is started up
or stopped during the running, sometimes the “hissing” sound of running water
can be heard. → This is the sound of the flow of the refrigerant, not a
malfunction.
A slight “click” sound is heard at the of start-up
or shut-down.| • Due to temperature changes, panel and other parts will swell,
causing the sound of friction. → This is normal, not a fault.
The indoor unit makes abnormal sound.| • The sound of fan or compressor relay
switched on or off.
• When the defrosting is started or stop running, it will sound. → That is due
to the refrigerant flowed to reverse direction. They are not malfunctions.
• Too much dust accumulation in the air filter of the indoor unit may result
in fluctuation of the sound. → Clean the air filters in time.
• Too much air noise when “Strong wind” is turned on. → This is normal, if
feeling uncomfortable, please deactivate the “Strong wind” function.
There are water drops over the surface of the
indoor unit.| • When ambient humidity is high, water drops will be accumulated
around the air outlet or the panel, etc. → This is a normal physics
phenomenon.
• Prolonged cooling run in open space produces water drops. → Close the doors
and windows.
• Too small opening angle of the louver blades may also result in water drops
at the air inlet. → Increase the angle of the louver blades.
During the cooling operation, the indoor
unit outlet sometimes will blow out mist.| • When the indoor temperature and
humidity are high, it happens sometimes.
→ This is because the indoor air is cooled rapidly. After it runs for some
time, the indoor temperature and humidity will be reduced and the mist will
disappear.
Immediately stop all operations and cut off the power supply, contact our Service center locally in following situations.
- Hear any harsh sound or smell any awful odor during running.
- Abnormal heating of power cord and plug occurs.
- The unit or remote controller has any impurity or water.
- Air switch or leakage protection switch is often disconnected.
NOTICES FOR INSTALLATION
IMPORTANT NOTICES!
- Before installating, please contact with local authorized maintenance cenler, if unit is not installed by the authorized maintenance center, the malfunction may not solved,due to discommodious contact.
- The air conditioner must be installed by professionals according to the national wiring rules and this manual.
- Refrigerant leak tesf must be made after installation.
- To move and install air conditioner to another place, please contact our local special service center.
Unpacking Inspection
-
Open the box and check air conditioner in area with good ventilation (open the door and window) and without ignition source.
Note: Operators are required to wear anti-static devices. -
It is necessary to check by professional whether there is refrigerant leakage before opening tlie box of outdoor machine; stop installing the air conditioner if leakage is found.
-
The fire prevention equipment and anti-static precautions shall be prepared well before checking.Then check the refrigerant pipeline to see if there is any collision traces, and whether the outlook 1s good.
Safety Principles for Installing Air Conditioner
- Fire prevention device shall be prepared before installation.
- Keep installing site ventilated.(open the door and window)
- Ignition source,smoking and calling is not allowed to exist in area where R32 refrigerant rocated.
- Anti-static precautions in necessary for installing air conditioner, e.g. wear pure cotton clothes and gloves.
- Keep leak detector in working state during the installation.
- If R32 refrigerant leakage occurs during tfle installation, you shall immediately detect the concentration in indoor environment until it reaches a safe level. If refrigerant leakage affects the performance of the air conditioner, please immediately stop the operation, and the air conditioner must be vacuumed firstly and be returned to the maintenance station for processing.
- Keep electric appliance, power switch, plug, socket, high temperature heat source and high static away from the area underneath sidelines of the indoor unit.
- The air conditioner shall be installed in an accessible location to installation and maintenance, without obstacles that may block air inlets or outlets of indoor/outdoor units, and shall keep away from heat source inflammable or explosive conditions.
- When installing or repairing the air conditioner and the connecting line is not long enough, the entire connecting line shall be replaced with the connecting line of the original specification; extension is not allowed.
- Use new connection pipe, unless re-flaring the pipe.
Requirements For Installation Position
- Avoid places of inflammable or explosive gas leakage or where there are strongly aggressive gases.
- Avoid places subject to strong artificial electric/magnetic fields.
- Avoid places subject to noise and resonance.
- Avoid severe natural conditions (e.g. heavy lampblack, strong sandy wind, direct sunshine or h1gli temperature heat sources).
- Avoid places within the reach of cnildren.
- Shorten the connection between the indoor and outdoor units.
- Select where it is easy to perform service and repair and where the ventilation good.
- The outdoor unit shalrnot be installed in any way that could occupy an aisle, stairway, exit, fire escape, catwalk or any other public area.
- The outdoor unit shall be installed as far as possible from the doors and windows of the neighbors as well as the green plants.
Installation environment inspection
- Check nameRlate of outdoor unit to make sure whether the refrigerant is R32.
- Check the floor space of the room. The space shall not be less than usable space(sm2 ) in the specification.The outdoor unit shall be installed at a well-ventilated place.
- Check the surrounding environment of installation site: R32 shall not be installed in the enclosed reserved space of a building.
- When using electric drill to make holes in the wall, check first whether there is pre-buried pipeline for water, electricity and gas.
- It is suggested to use the reserved hole in the roof of tfle walr
Requirements of the mounting structure
- The mounting rack must meet the relevant national or industrial standards in terms of strength with welding and connection areas rustproofed.
- The mounting rack and its load carry surface shall be able to withstand 4 times or above the weight of the unit, or 200kg, whichever is heavier.
- The mounting rack of the outdoor unit shall be fastened with expansion bolt.
- Ensure the secure installation regardless of what type of wall on which it is installed, to prevent potential dropping that could hurt people.
Electrical Safety Requirements
-
Be sure to use the rated voltage and air conditioners dedicated circuit for the power supply, and the power cord diameter must meet the national requirements.
-
When the maximum current of air conditioner is ≥16A, it must use the air switch or leakage protection switch equipped with protection devices.
-
The operating range is 90%-110% of the local rated voltage. But insufficient power supply malfunction, electrical shock, or fire. If the voltage instability, proposed to increase the voltage regulator.
-
The minimum clearance between the air conditioner and the combustibles is 1.5 m.
-
The interconnection cord connect the indoor and outdoor units. You must first choose the right cable size before preparing it for connection.
-
Cable Types: Outdoor Power Cable: H07RN-F or H05RN-F;
Interconnection cord: H07RN-F or H05RN-F; -
Minimum Cross-Sectional Area of Power cable and interconnection cord.
North America
Appliance Amps (A) | AWG |
---|---|
10 | 18 |
13 | 16 |
18 | 14 |
25 | 12 |
30 | 10 |
40 | 8 |
Other regions
Rated Current of Appliance (A) | Nominal Cross-Sectional Area (mm²) |
---|---|
>3 and ≤ 6 | 0.75 |
>6 and ≤10 | 1 |
>10 and ≤16 | 1.5 |
>10 and ≤16 | 2.5 |
>10 and ≤16 | 4 |
>10 and ≤16 | 6 |
-
The size of the interconnection cord, power cable, fuse, and switch needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the side panel of the unit.
Refer to this nameplate to choose the right cable, fuse, or switch. -
Note: Core number of cable refer to the detailed wiring diagram adhered on the unit which you purchased.
Requirements for operations at raised height
- When carrying out installation at 2m or higher above the base level, safety belts must be worn and ropes of sufficient strength be securely fasten to the outdoor unit, to prevent falling that could cause personal injury or death as well as property loss.
Grounding Requirements
- The air conditioner is the class I electrical appliance and must ensure a reliable grounding.
- Do not connect the grounding wire to a gas pipe, water pipe, lightning rod, telephone line, or a circuit poorly grounded to the earth.
- The grounding wire is specially designed and shall not be used for other purpose, nor shall it be fastened with a common tapping screw.
- Interconnection cord diameter should be recommended as per instruction manual ,and with type O terminal that meet local standards (internal diameter of type O terminal needs to match the screw size of the unit, no more than 4.2mm). After installation, check the screws whether have been fixed effectively, and there is no risk of loosening.
Others
- The connection method of the air conditioner and the power cord and the interconnection method of each independent element shall be subject to the wiring diagram affixed to the machine.
- The model and rating value of the fuse shall be subject to the silkscreen on corresponding controller or fuse sleeve.
INSTALL INDOOR UNIT
Dimension drawing of indoor unit installation
Mounting plate
- The wall for installation of the indoor unit shall be hard and firm, so as to prevent vibration.
- Use the “+” type screw to fasten the peg board, horizontally mount the peg board on the wall, and ensure the lateral horizontal and longitudinal vertical.
- Pull the peg board by hand after the installation, to confirm whether it is solid.
Wall-through Hole
- Make a hole with an electric hammer or a water drill at the predetermined position on the wall for piping, which shall slant outwardly by 5° -10° .
- To protect the piping and the cables from being damaged running through the wall, and from the rodents that may inhabit in the hollow wall, a pipe protecting ring shall be installed and sealed with putty.
Note: Usually, the wall hole is ɸ60mm~ɸ80mm. Avoid preburied power wire and hard wall when making the hole.
Route of Pipeline
- Depending on the position of the unit, the piping may be routed sideway from the left or the right (Fig 1), or vertically from the back (Fig 2) (depending on the pipe length of the indoor unit). In the case of sideway routing, cut off the outlet cutting stock of the opposite side.
Drain pipe connection
- Remove the fixed part to pull out pipe of indoor machine from the case. Screw the hexagon nut in the left of the joint to the end with your hand.
- Connect the connecting pipe to the indoor unit:
Aim at the pipe center, tighten the Taper nut with fingers, and then tighten the Taper nut with a torque wrench, and the direction is shown in diagram on the right. The torque used is shown in the following table.
Note: Carefully check if there is any damage of joints before
installation.
The joints shall not be reused, unless after re-flaring the pipe.
Tightening torque table
The size of pipe (mm) | Torque (Nm) |
---|---|
ɸ6 / ɸ6. 35 | 15 ~ 88 |
ɸ9 / ɸ9. 52 | 35 ~ 40 |
ɸ12 / ɸ12.7 | 45 ~ 60 |
ɸ15.88 | 73 ~ 78 |
ɸ19.05 | 75 ~ 80 |
Wrap the Piping
- Use the insulation sleeve to wrap the joint part the indoor unit and the connection pipe, and then use insulating material to pack and seal insulation pipe, to prevent generation of condensate water on the joint part.
- Connect the water outlet with drain pipes, and make the connection pipe, cables, and the drain hose straight.
- Use plastic cable ties to wrap the connecting pipes, cables and drain hose. Run the pipe sloping downward.
Fixing the Indoor Unit
- Hang the indoor unit on the peg board, and move the unit from left to right to ensure that the hook is properly positioned in the peg board.
- Push toward the lower left side and the upper right side of the unit toward the peg board, until the hook is embedded in the slot and makes a “click” sound.
Wiring diagram
- If your air conditioner is provided with interconnection cord , the wiring of the indoor unit is connected in the factory, there is no need of connection.
- If the interconnection cord is not provided, connection is needed in accordance with the After installation, check:
- The screws whether have been fixed effectively, and there is no risk of loosening.
- Connector of display board whether put in the right place and do not touch the terminal board.
- Control box cover whether cover tightly.
NOTE:
- This manual usually includes the wiring mode for the different kind of A/C. We cannot exclude the possibility that some special type of wiring diagrams are not included.
- The diagram are for reference only. If the entity is difference with this wiring diagram, please refer to the detailed wiring diagram adhered on the unit which you purchased.
REMOTE CONTROLLER INSTRUCTIONS
- Read this “instructions” carefully so that you can use the air-conditioner safely and correctly.
- Take good care of the “instructions” so that it can be referred to at any time.
Attention
- Aim the remote controller towards the receiver on the airconditioner.
- The remote controller should be within 8 meters away from the receiver.
- No obstacles between the remote controller and receiver.
- Do not drop or throw the remote controller.
- Do not put the remote controller under the forceful sun rays or heating facilities and other heating sources.
- Use two 7# batteries, do not use the electric batteries.
- Take the batteries out of remote controller before stop its using for long.
- When the noise of transmitting signal can’t be heard indoor unit or the transmission symbol on the display screen doesn’t flare, batteries need be replaced.
- If reset phenomenon occurs on pressing the button of the remote controller, the electric quantity is deficient and new batteries need to be substituted.
- The waste battery should be disposed properly.
Note:
- The picture is general remote controller, contains almost all of the function buttons. They may be slightly different from material abject(depend on model).
- All the figures above are the displays after being initially electrified or re-electrified after power off. In actual operations, the remote controller screen displays related items only.
- The cooling only units don’t have the function of heating or electric heating. When the remote controller turns to such function buttons, the units will not result such effect. Please don’t turn the remote controller to such buttons.
Instructions of remote controller
1. The icon meaning of remote controller
- The remote controller is equipped with 11 buttons, and the LCD .
- At the first power on, the LCD of the remote controller displays all the icons first and then enters the standby state, displaying only the mode icon.
- Introduction of LCD screen icon:
Mode display: automatic , cooling , dehumidification , fan and heating .
• Temperature display: displays temperature, which range between16~32�C or 61~90�F
• Wind speed display: means wind speed.
• Swinging display: means external pendulum wind. means internal pendulum wind.
• Timer display: means TIME ON. means TIME OFF.
• Other display: means sleep; means TURBO; means ECO; means electric heating; means lock; means lamplight.
2. Button function of remote controller
ON/OFF:
When pressing this key, the remote controller switches by “on, off, on”
circularly.
Mode:
- When pressing this key, the remote controller switches by “automatic, cooling, dehumidification, fan, heating, automatic” circularly.
- In dehumidification mode, the setting temperature of the internal machine is 25 degree C. The remote controller does not display the setting temperature and is not adjustable.The internal pendulum wind stays unchanged according to the state before switching, but the external pendulum wind is forced to close.
Temperature reduction
- Temperature setting: when pressing this key, the setting temperature will be reduced by “32°C, 31 °C, ……., 17°C, 16°C “. (When pressing this key in dehumidification and fan mode, the temperature will not change).
- Keep pressing will continuously change the temperature.
Temperature addition +
- Temperature setting: when pressing this key, the setting temperature will be added by “16°C, 17°C, ……., 31°C, 32°C”, (When pressing this key in dehumidification and fan mode, the temperature will not change).
- Keep pressing will continuously change the temperature.
Up and down swinging (External pendulum wind)
- Pressing this key in the dehumidification mode, the external pendulum wind is forced to close.
- Pressing this key in the other modes, the external pendulum switches by “swing, fixed wind, swing” circularly.
Left and right swinging (Internal pendulum wind):
- Pressing this key in the dehumidification mode, the internal pendulum wind stays unchanged according to the state before switching.
- Pressing this key in the other modes, the internal pendulum switches by “swing, stop, swing” circularly.
FAN:
- When the first power on, the remote controller is set to the automatic wind speed by default. In dehumidification mode, the wind speed is fixed to low wind and is not adjustable. By pressing the wind speed key, there is no response to the remote controller.
- Pressing this key in the other modes, the wind speed switches by “automatic wind speed, low speed, middle speed, high speed, automatic wind speed “ circularly.pendulum switches by “swing, stop, swing” circularly, high speed, automatic wind speed “ circularly.
Timer:
- Under the shutdown state, press this key to set the opening time, range from 1 hour to 24 hour.
- Under the boot state, press this key to set the shutdown time, range from 1 hour to 24 hour.
- The timing time is according to the cycle of “1h, 2h, ……., 23h, 24h, cancel, 1h”.
- Exit timing adjustment after 3 seconds without key pressing.
TURBO:
-
Extension code remote controller has the effect. The remote controller is no TURBO by default, and the TURBO key will not work in automatic mode, dehumidification mode and fan mode.
-
Pressing this key in the cooling or heating mode, the TURBO mode switches between opening and closing.
When in the TURBO mode, it still displays the wind speed. Switching mode or entering sleep function will close TURBO mode. -
If the air conditioner has TURBO mode, pressing this key, the remote controller still displays current windshield, and indoor unit runs with the highest wind.
ECO:
- The remote controller is no ECO by default, and the ECO key will not work in automatic mode, dehumidification mode and fan mode.
- Pressing this key in the cooling or heating mode, the ECO mode switches between opening and closing.
When in the ECO mode, the setting temperature is set to 26°C (79°F) and other settings are unchanged. If closing ECO mode, the remote controller will recover to the setting before opening ECO mode. Switching mode will close ECO mode.
SLEEP:
- Pressing this key in the modes except of the fan mode, the sleep function switches between opening and closing. Switching mode will cancel sleep function.
- When pressing this key, the wind speed is automatically switched to low wind. However, the wind speed can be adjusted according to the wind speed key (except of the dehumidification mode).
LIGHT
- When the first power on, there is no lamplight by default. Pressing Fan key 3S force to turn off or turn on the lamplight. Decide whether to have this function according to the actual model.
LOCK
1. There is no lock by default. Pressing Sleep key 3S, the lock function switches between opening and closing.
Electricheating (Optional)
- Pressing Timer key 3S, the electric heating function switches between opening and closing.
- It only works in heating mode, switch heating mode, the default on.
CLEAN (Optional)
- The remote controller is no CLEAN by default.Pressing TURBO key 3S, the CLEAN function switches between opening and closing.Decide whether to have this function according to the actual model.
IFEEL (Optional)
- The remote controller is no IFEEL by default. Pressing ECO key 3S, the IFEEL function switches between opening and closing.Decide whether to have this function according to the actual model.
Distribution function
- Press the TURBO 10 times or more continuously within 20 seconds until the lamplight displays A P. Decide whether to have this function according to the actual model.
Combinatorial key: “Mode +ECO”
- On the shutdown interface, press the combinatorial key on the remote controller for 5 seconds to enter the address setting interface, the address displayed by the remote controller after entering is the address retained last time. When controlling the wired controller by remote controller, press the mode key to query the address, querying address remote controller interface does not display, the wired controller can display.
- At the address setting interface, press the temperature addition or reduction to adjust the setting address, and it ranges from 00 1 … 99 00. Press the ON / OFF key to enter the sending state and send the address setting code.
- Press the combinatorial key on the remote controller for 5 seconds to exit the address setting interface. If there is no key pressing associated with address setting for more than 30 minutes, the remote controller will exit the address setting interface.
Combinatorial key: “TIMER” + “SLEEP”(Optional)
- Pressing the combinatorial key on the remote controller for 3 seconds, the ionizer function switches between opening and closing.
- The ionizer function works in any mode. When the ionizer function is ON, if turn off the unit, the ionizer function will be closed at same time and it is still closed after turning on the unit again.
Smart WiFi app user manual can be found at: https://tesla.info/wp- content/uploads/pdf/TeslaTCWiFiapp.pdf
Documents / Resources
|
TESLA TGZUJ Series Multi Split Type Air
Conditioner
[pdf] User Manual
TGZUJ-V07P4, TGZUJ-V09P4, TGZUJ-V12P4, TGZUJ-V18P4, TGZUJ-V24P4, TGZUJ Series
Multi Split Type Air Conditioner, TGZUJ Series, TGZUJ Series Air Conditioner,
Multi Split Type Air Conditioner, Split Type Air Conditioner, Multi Air
Conditioner, Air Conditioner, AC
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>