Operation & Maintenance Manual
CuddleBlanket System for the
Cooling of a Single Deceased
HC17 Cuddle Blanket System
Model designation: HC170
Product Type: Mortuary Cooling System
THIS IS NOT A MEDICAL DEVICE
Please read this manual before use
This instruction manual is compiled to assist the installation, commissioning,
servicing and operation of the CuddleBlanket cooling system. This unit has
been designed for continuous operation providing that it has been installed
and maintained in strict accordance with this manual. The user should read the
contents before installing the unit.
If the machine is not installed correctly then safety and protective measures
or functions may not operate correctly or as intended.
Any liability for injury or damage caused by the incorrect installation and
use of this machine lies exclusively with the user.
The manufacturer will not accept responsibility for damage caused by incorrect
installation commissioning or operation.
Note: The machine contains powered electrical devices and moving parts.
System components
- 1 x sturdy plastic storage/carry case with metal closures
- 1 x mains powered cooling unit
- 1 x mains power cord
- 1 x flexible plastic cooling pad (reusable)
- 1 x flexible insulated connection hose
- 1 x insulated over blanket
- 1 x bottle of Coldflow2 coolant top-up, 2 litres
- 1 x loop back test hose
- 1 x user guide
Connections
Use only hoses, cooling pads and ColdFlow2 approved by CuddleBlanket.
Electrical installation
The CuddleBlanket system should be installed by a competent person. The
electrical connections should be made using the 13A plug and lead supplied.
An IEC socket is fitted on the side of the unit.
Ensure the supply is according to the electrical requirements stated on the
serial number label on the rear of the unit. This label identifies the
voltage/frequency and the maximum current.
Quick Start Guide
We would strongly advise that at least 3 hours has elapsed between the deceased’s passing and use of the cooling system. The reason is that the body will still be very warm and you will be fully insulating the deceased so it is strongly advised to let the deceased undertake some natural cooling for a few hours.
-
Setting up the CuddleBlanket
Ensure unit is switched OFF at the rocker switch adjacent to the power cord socket. Plug in the electrical cable ensuring the unit is kept flat and in a wellventilated area. If the room is small then it is best to leave adjoining doors open where possible. -
Connecting the hose
Plug the 2 male connectors of the long blue insulated hose firmly into the ports on the side of the unit. You will hear a click. It does not matter which way round you connect the hoses to the unit. -
Connecting the cooling pad
Place the cooling pad over the deceased, just below the neck. We recommend placing a sheet over the deceased first. Then use another sheet over the cooling pad before using the supplied insulated duvet. This will help with cleaning and any condensation that may build up. You can place any blanket or cover over the supplied duvet, it will not affect the system.
Ensure the duvet is tucked around the deceased to minimise warm ambient air reaching the cool pad. -
Switch on the CuddleBlanket
Switch the CuddleBlanket ON using the black rocker on/off switch adjacent to the power cord socket. -
You may need to top up the CuddleBlanket with cooling fluid (Coldflow2)
Fluid will begin to circulate from the CuddleBlanket through the hoses and to the cooling pad. The fluid level within the reservoir window may begin to drop and the alarm may sound briefly. For additional ColdFlow2 fluid, please contact info@flexmort.com.
No alarm – the CuddleBlanket is fully operational; please move to stage -
Alarm sounds – Do not turn off the unit, unscrew the filler cap and continuously fill the unit with Coldflow2 cooling fluid using a jug or funnel, avoiding spillage onto the unit. Fill approximately to the red line shown on the reservoir window.
-
Setting the temperature
The machine will remember the temperature it was set to during its last operation.
Don’t need to change the temperature? Please move to stage 7.
Need to change the temperature? Follow the 3 steps below. The display will run through a selftest programme for the first few seconds after switching on the system, this is normal.
1. Press the ‘P’ button on the display once. ‘SP-1’ (set point) will be displayed in red at the top of the display.
2. Using the up and down arrow, select the required temperature in green. 8-10°C is usual.
3. Press the ‘P’ button again to set the system. The machine will cool the circulating fluid to this temperature The temperature of the fluid is shown by the red display and the green shows the set point. -
Turning off the system
Switch off the unit at the black rocker switch, remove the hose (the alarm will sound which is normal) and unplug the machine. A few drops of the fluid will be lost from the connectors, this is normal.
IMPORTANT: Always allow the cooling pads to warm back up to room temperature before folding to pack away as this will increase the life of the pads. -
Warning lights, alarm and topping up the CuddleBlanket unit with Coldflow2 fluid
The alarm will sound and the red LED light will illuminate if there is an obstruction to flow or if the reservoir is low on fluid. (Fig.1)
The reservoir should always be kept topped up during operation. Leave the unit switched on, remove the filler cap and top up slowly. (Fig.2)
Basic Specification
Product Description
This Flexmort CuddleBlanket is a closed circuit recirculation unit designed
for continuous operation and is used to cool bodies using a ‘closed loop’
cooling system through a cooling pad and hose.
Specification
Fluid: Use only Flexmort Ltd Coldflow2 cooling fluid. A data sheet is
available upon request.
Note: Internal damage will occur if any other fluid is used (including water).
Electrical Supply
Mains Supply: 230Va/50Hz or 115Vac/60Hz
Total system AC current load:
230Vac – 3.7A (typical) maximum current 5A
115Vac – 7.0A (typical) maximum current 8A
Physical (all measurements are approximate)
Overall chiller unit dimensions: 365mm x 249mm x 349mm
Cooling pad dimensions: 100cm x 70cm
Weight: 11kg (drained)
Unpacking and Positioning
Unpacking the CuddleBlanket
Before unpacking the CuddleBlanket unit, inspect the blue packing case for any
signs of damage.
Carefully remove unit from packing case. Check unit for signs of transit
damage.
If transit damage is discovered, immediately inform both the delivering
haulage company and Flexmort in writing. Take photographic evidence and retain
all packaging materials.
Please observe all local and governing recycling requirements when disposing
of packaging materials.
Positioning the Equipment
- The equipment must only be positioned indoors.
- The CuddleBlanket chiller unit must be kept upright at all times.
- The equipment must be positioned on a level surface.
- Avoid positioning in an area where other plant operations create a high ambient temperature.
- The chiller will operate most efficiently in ambient temperatures up to 23°C
- The equipment must be installed in a well-ventilated area. Avoid obstructing the air grilles as these allow fresh air to enter the unit and warm exhaust air to escape.
Note: Recirculating hot exhaust air will adversely affect the performance of the coolant
Symbol | Description |
---|---|
Hazard — Electricity | |
Protective Earth | |
Mains Fuse | |
Power on/ off | |
‘Power supply 1’ | 24Vdc power supply operating when lit — Unit ON |
‘Power supply 2’ | 12Vdc power supply operating when lit — Unit ON |
‘Fluid Fault’ | Fluid flow fault when lit. Normally unlit |
Compliance
- CE compliant, EMC/LV compliant.
- This cooler complies with current European Council Directives.
- UL certification pending.
Any changes to the construction or its intended use by the customer may void the compliance.
Moving and Handling
When moving the unit please ensure the two side handles are used.Before moving the unit to another location ensure the unit is turned off and the electrical supply is disconnected from the supply and the unit.
Maintenance
Unless otherwise stated always ensure the power supply is off and
disconnected before carrying out any maintenance and ensure that power cannot
be reapplied accidentally.
Only qualified personnel should only carry out maintenance work
During fault finding diagnostics and maintenance, it may be necessary to
remove panels, which expose the dangers of electrical equipment. Only
qualified personnel who are fully trained, aware and equipped to repair this
equipment should complete such work.
Isolate the unit from the mains electrical supply before opening control
panels or removing any exterior panel.
Never alter settings (apart from temperature set point) without first
consulting us.
General Maintenance
- Clean CuddleBlanket chiller metal surfaces with a clean damp cloth.
- Clean plastic surfaces with any plastic safe cleaner or disinfectant.
- Model HC170. Issue Number 8. Date 17.01.2022. 9
- Ensure all external grilles are clear of dust and debris
- Insulation blanket can be gently washed at 30°C. Reshape while damp. Do not tumble dry
- Check all screwed fittings and panels are in place
- Perform Portable Appliance Test (PAT) including power cord
- It is recommended that a yearly preventative maintenance check is carried out by us.
Disposal of equipment (End of service life)
UK WEEE Regulations 2006
This equipment has been designed using recyclable and RoHS compliance standard
parts (where design conditions permit). Please read the information below for
how to dispose of this equipment.
For business users in the European Union:
At the end of its service life the unit can be returned for decommissioning
and recycling to CuddleCot.
Please contact us on +44 (0)8455 333561 for further information.
Model HC170. Issue Number 8. Date 17.01.2022
CuddleCot
Unit 1C Cotswold Buildings
Barnwood Point, Corinium Avenue
Gloucester, GL4 3HX
United Kingdom
www.cuddlecot.com
Documents / Resources
|
CuddleCot HC17 Cuddle Blanket
System
[pdf] Instruction Manual
HC17 Cuddle Blanket System, HC17, Cuddle Blanket System, Blanket System,
System
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>