HALO IB517057ML LED Downlight Instruction Manual
- June 10, 2024
- HALO
Table of Contents
- IB517057ML LED Downlight
- HALO Commercial LED Recessed Lighting Fixture
- Important Safety Instructions
- Installation Instructions
- Driver Replacement
- HC4/HC6 LED Commercial Open Frame Installation
- REMODEL INSTALLATION
- YEAR LIMITED WARRANTY
- LIMITATION OF LIABILITY
- FCC Statement
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
IB517057ML LED Downlight
HALO Commercial LED Recessed Lighting Fixture
The HALO Commercial LED Recessed Lighting Fixture (IB517057ML) is a high- quality lighting solution that is designed to meet the latest NEC requirements. It is available in two sizes: HC4 and HC6, with a 5.625 diameter hole for HC4 and 7.25 diameter hole for HC6. The fixture is available in both new construction and remodel options.
Important Safety Instructions
Before attempting installation of any recessed luminaire retrofit, check your local electrical code. This code sets the wiring standards for your locality and should be carefully studied before starting. When using the product, basic precautions should be followed to ensure safety.
Installation Instructions
New Construction
- If the luminaire is to be switched from a wall switch or dimmer, make sure the black supply wire is properly connected to the switch or dimmer.
- Cut a hole in the ceiling of the appropriate size for the fixture being installed.
- Install the rough-in section through the hole.
- Loosen the three screws holding the adjustable collar and drop the collar down so that it rests below the ceiling plane
- Attach the two remodel clips, one per notch, to the adjustable collar. Each clip should fit inside their respective notches, making it flush with the collar.
- Adjust the collar back to the ceiling plane and tighten the three screws to secure the collar in place. The clips should now rest against the ceiling, holding the fixture in place.
Remodel Installation
- Remove the two No Fuss bar hangers and brackets by removing the two screws that attach each bracket to the plaster frame.
- Remove the plastic bag with remodel clips from inside the junction box. Complete wiring of the fixture to power supply prior to installing it in the ceiling.
- Cut a hole in the ceiling of the appropriate size for the fixture being installed.
- Install the rough-in section through the hole.
- Loosen the three screws holding the adjustable collar and drop the collar down so that it rests below the ceiling plane.
- Attach the two remodel clips, one per notch, to the adjustable collar. Each clip should fit inside their respective notches, making it flush with the collar.
- Adjust the collar back to the ceiling plane and tighten the three screws to secure the collar in place. The clips should now rest against the ceiling, holding the fixture in place.
Driver Replacement
To replace the driver, follow these steps:
- Ensure that the power supply is turned off before removing and replacing the driver. Driver replacement should be completed by a qualified electrician.
- Remove the junction box cover that has driver attached.
- Disconnect line, common, and ground wires from driver. Disconnect red and blue light engine wires from driver.
- Remove two screws attaching driver to junction box cover and attach new driver with same screws.
- Reconnect line, common, ground, and red and blue light engine wires to new driver.
- Reattach junction box cover with driver back to junction box and resume normal operation.
Wiring Diagrams for D010
HC4/HC6 LED Commercial Open Frame Installation
IMPORTANT SAFETY INSTRUCTIONS
When using product, basic precautions should always be followed, including the following:
- Heed all warnings, including below warnings AND those included on product.
- HALO Commercial recessed luminaire (fixtures) are designed to meet the latest NEC requirements. Before attempting installation of any recessed luminaire retrofit check your local electrical code. This code sets the wiring standards for your locality and should be carefully studied before starting.
WARNING
- Read and follow these instructions.
- Risk of fire. MINIMUM 90° C SUPPLY CONDUCTORS. If uncertain, consult an electrician.
- Risk for Fire or Electric Shock: Please consult an electrician for installation if uncertain of luminaire electrical systems.
- Risk of electric shock. To avoid possible electrical shock, be sure that power supply is turned off at fuse box or circuit breaker before installing or servicing luminaire.
CAUTION
- Edges may be sharp. Wear gloves while handling.
- Connect fixture to a compatible AC power source. (Fixture is universal voltage 120V-277V, 50-60Hz.) Any other connection voids the warranty.
- Fixture should be installed by persons with experience in building wiring or by a qualified electrician. The electrical system, and the method of electrically connecting the fixture to it, must be in accordance with the National Electrical Code and local building codes.
SAVE THESE INSTRUCTIONS AND WARNINGS.
INSTALLATION FOR ROUGH-IN SECTION NEW CONSTRUCTION
Note: If luminaire is to be switched from wall switch or dimmer, make sure black supply wire is properly connected to the switch or dimmer (follow switch/dimmer instructions). DO NOT connect the white supply wire to the switch.
- Make certain no bare wires are exposed outside the connectors.
- Luminaire is designed for installation where it will
NOT come in contact with insulation. Thermal insulation must be kept a minimum of 3” away from the luminaire. (FIG. 1)
- Locate center of proposed opening on ceiling tile or ceiling structure and cut appropriate sized hole. (5.625” diameter hole for HC4, 7.25” diameter hole for HC6).
- Install rough-in section to T-Grid or ceiling structure using “No Fuss” bar hangers attached to fixture. Secure bar hangers in place by bending the end sections to lock to grid. (FIG. 2)
- Adjust collar so that it sits flush with ceiling plane, if necessary. (FIG. 3)
- Remove junction box cover and connect supply lead wires in accordance with your local electrical codes or N.E.C. Replace junction box cover.
REMODEL INSTALLATION
-
Remove the two “No Fuss” bar hangers and brackets by removing the two screws that attach each bracket to the plaster frame. (FIG. 4)
-
Remove plastic bag with remodel clips from inside junction box. Complete wiring of fixture to power supply prior to installing fixture in ceiling.
-
Cut hole in ceiling: 5.625” diameter hole for HC4 and 7.25” diameter hole for HC6. Install rough-in section through hole. (FIG. 5)
Note: The hole sizes shown are maximum sizes. The hole diameter should be cut just large enough to allow the rough-in section to “friction fit” through it. Not adhering to the max hole diameters may not ensure proper function of the remodel clips. -
Loosen the three screws holding the adjustable collar and drop the collar down so that it rests below the ceiling plane. Attach the two remodel clips, one per notch, to the adjustable collar. Each clip should fit inside their respective notches, making it flush with the collar. (FIG. 6)
-
Adjust the collar back to the ceiling plane and tighten the three screws to secure the collar in place. The clips should now rest against the ceiling, holding the fixture in place. (FIG. 7)
DRIVER REPLACEMENT
To avoid possible electric shock, be sure that power supply is turned off before removing and replacing driver. Driver replacement should be completed by a “qualified electrician”.
- Remove junction box cover that has driver attached.
- Disconnect “line”, “common” and “ground” wires from driver. Disconnect red and blue light engine wires from driver.
- Remove two screws attaching driver to junction box cover and attach new driver with same screws.
- Reconnect “line”, “common”, “ground” and red and blue light engine wires to new driver.
- Reattach junction box cover with driver back to junction box and resume normal operation.
Constructions built before Jan 2022 may have gray wire for 0-10 dimming control present. In these cases, the installer will label the gray building wire as a 0-10 dimming wire and connect to our product’s pink 0-10V dimming control wire. Reference NFPA70 (2020 NEC), section 410.69.
YEAR LIMITED WARRANTY
THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
Cooper Lighting Solutions warrants to customers that, for a period of five years from the date of purchase, Cooper Lighting Solutions products will be free from defects in materials and workmanship. The obligation of Cooper Lighting Solutions under this warranty is expressly limited to the provision of replacement products. This warranty is extended only to the original purchaser of the product. A purchaser’s receipt or other proof of date of original purchase acceptable to Cooper Lighting Solutions. This is required before warranty performance shall be rendered.
This warranty does not apply to Cooper Lighting Solutions products that have been altered or repaired or that have been subjected to neglect, abuse, misuse or accident (including shipping damages). This warranty does not apply to products not manufactured by Cooper Lighting Solutions which have been supplied, installed, and/or used in conjunction with Cooper Lighting Solutions products. Damage to the product caused by replacement bulbs or corrosion or discoloration of brass components are not covered by this warranty.
LIMITATION OF LIABILITY
IN NO EVENT SHALL COOPER LIGHTING SOLUTIONS BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL THE LIABILITY OF COOPER LIGHTING SOLUTIONS FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR MODIFICATION OF COOPER LIGHTING SOLUTIONS PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE, EXCEED THE PURCHASE PRICE OF COOPER LIGHTING SOLUTIONS PRODUCTS GIVING RISE TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES.
All returned products must be accompanied by a Return Goods Authorization Number issued by the Company and must be returned freight prepaid. Any product received without a Return Goods Authorization Number from the Company will be refused. Cooper Lighting Solutions is not responsible for merchandise damaged in transit. Repaired or replaced products shall be subject to the terms of this warranty and are inspected when packed. Evident or concealed damage that is made in transit should be reported at once to the carrier making the delivery and a claim filed with them. Reproductions of this document without prior written approval of Cooper Lighting Solutions are strictly prohibited.
FCC Statement
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
- This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
- This device complies with ISED ICES
Stand
HC4 / HC6 LED Commercial Open Frame Installation Instructions
www.cooperlighting.com
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Cooper Lighting Solutions is a registered trademark. All trademarks are property of their respective owners.