RAIN HARVESTING TAAG01 Plumbed Air Gaps Installation Guide

June 10, 2024
Rain Harvesting

RAIN HARVESTING TAAG01 Plumbed Air Gaps

PRODUCT DETAILS

Stop storm water surges contaminating the rainwater in your tank and keep mosquitoes out with our plumbed air gaps.
Protect your rainwater from contamination by preventing stormwater backflow ­ and mosquitoes ­ entering your tank through your outlet pipes.

Code Size Country
TAAG01 TAAG02 90mm
100mm Australia
TAAG101 3″ USA
TAAG201 80mm New Zealand

Installation

WHAT’S IN THE BOX?
  • Air Gap
TOOLS/MATERIALS YOU MAY REQUIRE
  • Marker pen
  • Tape measure
  • Saw
  • Screws for mounting
  • Solvent weld glue
INSTALLATION – TAAG01, TAAG101 & TAAG201
  1. Select an installation point for your Air Gap. This must be a vertical section of pipe after your tank overflow. Where practical, we recommend installing your Air Gap at shoulder height toprovide more convenient access for maintenance. Consider whether your stor mwater is a wetor “charged” line to determine the appropriate minimum installation height.
  2. Remove a 142mm section of pipe at your desired installation point. The Air Gap incorporates two 90mm female sockets that glue directly to 90mm pipe. If you’re using adaptors to fit the Air Gap to your existing, non-90mm pipe, you may need to remove an additional length of pipe to allow for these adaptors. Ensure all cut edges are clean and smooth.
  3. Orient your Air Gap so it is the right way up. To do this, refer to the “Install this side facing up” instructions on the product.
  4. Apply solvent weld glue to inside the sockets of the Air Gap or adaptors and also outside of each pipe. 5 – Fit the Air Gap into position and insert both pipes into the sockets and hold until glue sets.
INSTALLATION – TAAG02
  1. Select an installation point for your Air Gap. This must be a vertical section of pipe after your tank overflow.
  2. There are 3 parts to your Air Gap (2 x insect proof screens and 1 x main body). Please remove the insect proof screens, then use solvent weld glue to glue the bodies into either end of the main body of the Air Gap.
  3. Remove a 220mm section of pipe at your desired installation point. The Air Gap assembly incorporates two 100mm female sockets that glue directly to 100mm pipe. Ensure all cut edges are clean and smooth.
  4. Orient your Air Gap so it is the right way up as shown in the diagram on the right. The mouth of the Air Gap catches the water flowing from the tank.
  5. Apply solvent weld glue to inside the sockets of the Air Gap and also outside of each pipe.
  6. Fit the Air Gap into position and insert both pipes into the sockets and hold until glue sets.

Product Specifications

Air Gaps

TAAG01, TAAG101 & TAAG201

TAAG02

Country Code A B C D
Australia TAAG01 90 F 157 196 154
TAAG02 100 F 160 252 168
USA TAAG101 3H SCH40 F / SDR35 F 6,.211 9.5′ 6.1″
New Zealand TAAG201 80 F 157 246 154
South Africa.. UK & India TAAG02 110 F 160 252 168

All dimensions are in mm unless otherwise stated.

Fitting guide:
F = Female / Socket Fitting
M = Male / Spigot Fitting (Pipe size)
IP = In-Pipe Fitting

Maintenance

Remove the insect proof screens by pulling the handle and clean off any build up of debris.
We recommend regularly inspecting your Air Gap’s mosquito-proof screens to remove any built-up dirt or debris.

Both screens can be easily removed for cleaning. To remove the top mosquito proof screen, simply turn it clockwise until it’s released. To remove the bottom mosquito-proof screen, simply lift it up. Hose or brush off both screens, then replace after cleaning. Ensure both screens are secure to maintain a mosquito-proof barrier.


A common misconception about collecting rainwater is that all you need is a roof, a tank and some rain. This ‘tanking’ approach cannot always be relied on to  deliver the volume – or quality – of water that you require. That is where we can help.
With some thought, your rain harvesting system can provide you with cleaner water and lots of it. Whether you’re completely reliant on tank water or wanting to keep the garden green, our simple steps will help you achieve your goal.
The Rain Harvesting approach to rainwater collection involves using tested and proven products to make quality rainwater available for use in and around your property. You don’t need much to get started and you will be surprised how easy it is to get the most out of your rainwater system.

How can we help you?

COMPLIANCE
  • AS/NZS 4020:2005 – Testing of products for use in contact with drinking water

DISCLAIMER This product specification is not a complete guide to product usage. Further information is available from Rain Harvesting Pty Ltd and from the installation and Operating instructions. This specification sheet must be read in conjunction with the installation and Operating Instructions and all applicable statutory requirement. Product specifications may change without notice. © Rain Harvesting Pty Ltd

how we can help, just give us a call on
+61 7 3248 9600
Or visit our website at
rainharvesting.com