RAIN HARVESTING CALM01 Calmed Inlet 100m Installation Guide

June 10, 2024
Rain Harvesting

RAIN HARVESTING CALM01 Calmed Inlet 100m

RAIN HARVESTING CALM01 Calmed
Inlet 100m Installation Guide-product

Calmed Inlet

Product Information

The Calmed Inlet is designed to prevent sediment from being stirred up and resuspended by calming the inflow of water into your tank. Without a Calmed Inlet, the inbound water can stir up the sediment at the base of the tank, especially if the water level is low. This reduces the quality of the water you’re about to use. The Calmed Inlet softens the flow to prevent this issue so you always have clear, fresh water ready for use.

The Calmed Inlet is available in different sizes and countries, as shown below:

Code Size Country
CALM01 100mm / 4″ Australia & New Zealand
CALM01 100mm / 4″ – 110mm USA
CALM01 105/110mm UK, South Africa & India
CALM01 110mm Europe

Installation Guide

The following tools/materials may be required for installation:

  • Tape measure
  • Marker pen
  • Saw
  • Solvent weld glue
  • Screws
  • Drill or screwdriver
  • 100mm / 4″ pipe

The installation process includes the following steps:

  1. Measure and mark the location for the Calmed Inlet.
  2. Cut the hole in the tank for the Calmed Inlet using the saw.
  3. Apply solvent weld glue to the Calmed Inlet and attach it to the tank.
  4. Attach the 100mm / 4″ pipe to the Calmed Inlet using screws.

Maintenance

When properly installed, your Calmed Inlet should be maintenance-free.

A common misconception about collecting rainwater is that all you need is a roof, a tank and some rain. This ‘tanking’ approach cannot always be relied on to deliver the volume – or quality – of water that you require. That is where we can help.
With some thought, your rain harvesting system can provide you with cleaner water and lots of it. Whether you’re completely reliant on tank water or wanting to keep the garden green, our simple steps will help you achieve your goal.
The Rain Harvesting approach to rainwater collection involves using tested and proven products to make quality rainwater available for use in and around your property. You don’t need much to get started and you will be surprised how easy it is to get the most out of your rainwater system.

How can we help you?

Contact Information

If you need more information or assistance, you can contact us at:

Phone: +61 7 3248 9600

Website: rainharvesting.com

PRODUCT DETAILS

Prevent sediment being stirred up and resuspended by calming the inflow of water into your tank. Without a Calmed Inlet, the inbound water can stir up the sediment at the base of the tank, especially if the water level is low.
This reduces the quality of the water you’re about to use. The Calmed Inlet softens the flow to prevent this issue so you always have clear, fresh water ready for use.

Installation

RAIN HARVESTING CALM01 Calmed Inlet 100m Installation
Guide-fig-2

HOW IT WORKS

Allows the calm and easy entry of water into your rain barrel to avoid redistributing any accumulated sediment.RAIN HARVESTING CALM01 Calmed Inlet
100m Installation Guide-fig-3

  1. Prepare your tank for installation of your Calmed Inlet. Remove your tank cover if you have one. Installing your Calmed Inlet is easier with an empty tank, but it is not essential.
  2. Measure the distance from your tank inlet to the bottom of your tank. This will allow you to calculate the length of pipe required to mount in between your tank inlet and the calmed inlet. Make sure you use enough pipe so that the calmed inlet sits flat on the bottom of the tank.
  3. Cut your inlet pipe and ensure both ends are clean and free from burrs and sharp edges.
  4. install the calmed inlet onto the end of the pipe that will sit inside the tank. Make sure to press the pipe firmly into the socket on the calmed inlet. If required, you can install a screw through the socket of the calmed inlet and into the pipe for extra secure fitment
  5. Place the calmed inlet in position on the bottom of the tank with the pipe rising towards the connection above your tank inlet.
  6. Glue the other end of the pipe into your inlet pipe fitting.

Product Specifications

RAIN HARVESTING CALM01 Calmed Inlet 100m
Installation Guide-fig-4

All dimensions are in mm unless otherwise stated.

Fitting guide:

  • F = Female / Socket Fitting
  • M = Male / Spigot Fitting (Pipe size)
  • IP = In-Pipe Fitting

DISCLAIMER T his product specification is not a complete guide to product usage. Further information is available from Rain Harvesting Pty Ltd and from the Installation and Operating Instructions. This specification sheet must be read in conjunction with the Installation and Operating Instructions and all applicable statutory requirement. Product specifications may change without notice. © Rain Harvesting Pty Ltd
rainharvesting.com

For more information or to find out how we can help, just give us a call on