RAIN HARVESTING WFRW13 Triple Action Filtration System Large Installation Guide
- June 10, 2024
- Rain Harvesting
Table of Contents
RAIN HARVESTING WFRW13 Triple Action Filtration System Large
PRODUCT DETAILS
This large capacity, single stage filter includes a carbon block filter which removes fine sediment down to 10 microns in size, and reduces colour,odour, and chlorine in your water.
Installation
WHAT’S IN THE BOX?
- Filter Housing
- Filter Cartridge(s)
- Housing Ring Spanner
- Wall bracket & screws
TOOLS/MATERIALS YOU MAY REQUIRE
- Tape measure
- Marker pen
- Pipe cutters
- Deburring tool
- PTFE (Teflon thread tape)
- 2 Threaded adaptors (isolation valve and refer to installation layout and existing pipework for further information.)
- Adjustable wrench
- Screwdriver
- Drill
- Anchors (for mounting bracket)
CAUTION:
Do not use with water that is microbiologically unsafe or with water of
unknown quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected water that may
contain filterable cysts. If not properly maintained, the use of this system
may increase
the bacterial content of the water unless supplementary treatment is provided.
GENERAL REQUIREMENTS
- Installation must be made in accordance with the Plumbing Code of Australia (PCA) by a licensed plumber only.
- Observe the use limits indicated on the filter label.
- If the pressure exceeds use limits, protect with a pressure reducer.
- Install an “anti-water hammer” system to protect the filter.
- Keep away from light sources.
- Keep away from excessive heat and cold (min. 4°C, max 45°C)
- Only use original Blue Mountain Co cartridges. The use of non-original cartridges may void the warranty.
- Before the installation, carefully lubricate the housing o-ring which is located at the bowl top.
- Before the installation, check if the hydraulic system has been set up according to local authority guidelines.
- Install the products in sheltered areas and protected from freeze and excessive heat.
- Please refer to Installation Layout to check the correct location of isolating valves and pressure control devices.
- The installation of any backflow prevention device must be in accordance with the Plumbing Code of
- Australia (PCA) and AS/NZS 3500.1 and comply with AS 2845.1:2010. Please refer to the Installation Layout section:a dual check valve is recommended; a single check valve or non-return valve is not acceptable.
- Internal water pressure in buildings should be limited to a maximum of 500 kPa (0.5 bar). The recommended pressure reducer must be WaterMarked and/or compliant with AS/NZS 3500.1 and installed in accordance with the Plumbing Code of Australia (PCA)
WARNING:
Water pressure above 500 kPa may damage connected products including water
filters and will void the product warranty
IN-OUT directions and vent-valve (VV) location in different models.
Only use PTFE thread seal tape to seal filter connections. Using other types of sealing material may void the warranty
Installation layout
- Water mains
- Dual check valve
- Pressure reducer
- By-pass (optional or check local authority guidelines)
- Anti-water hammer device (expansion vessel)
- Filtering unit of any model
- Isolating Valve
- Other Utilities
INSTALLATION START-UP AND FIRST USE
- Turn-off water mains
- Avoid all kinds of tension by using original wall brackets as a support
- The installation of a bypass is recommended.
- Connect the inlet to the product’s side with the indication IN and the outlet to the side with the indication OUT.
- Connect to pipes using cylindrical (parallel) fittings or US conical (tapered) fittings, possibly with flexible hoses.
- Use only sealing tape as a sealant for the connections.
- If the product is supplied without cartridge/s, unscrew the housing bowl from the head and insert the cartridge/s, lubricate the o-ring, then screw the bowl to the head and tighten with the original spanners.
- Turn on the water mains.
- Unscrew the vent valve and wait for the air purge, then screw and tighten the vent valve. After installation, slowly turn on a water supply (tap) downstream of the installed unit and let the water flow for at least 5 minutes to flush the system before use.
WARNING:
Make sure that there are no water leaks from the product, and ensure you
control the tightening between the housing head and the housing bowl. Continue
checking that the tightening is good and there is no water leakage for 48
hours following the Installation and start-up. In case of leakage, open the
housing, remove the o-ring from the bowl, place a new o-ring, and apply
lubricant, then re-tighten the bowl to the head and repeat the leakage check
as above.
WARNING:
For the correct operation of this appliance, it is essential to observe the
manufacturer’s instructions.
Product Specifications
Triple Action Filtration System – Large
All dimensions are in mm unless otherwise stated.
Filter Housing
Flow rate will depend on cartridge selection, supply pipe pressure and size.
Thread Type
Included cartridge
Multi-Action Filter Cartridge
Filter Cartridge Replacement
- Before opening the housing turn off the water mains.
- Release the pressure from the product by unscrewing the vent valve.
- Open the housing unscrewing the bowl from the head.
- Remove the used cartridge.
- Wipe clean the filter housing with cold water and a soft sponge.
- Open the new cartridge wrap and discard the wrap. Carefully read the leaflet/sticker for directions and keep it for future reference.
- Insert the new cartridge and place it into the housing
- Lubricate the o-ring with lubricant or change it with a new o-ring.
- Tighten the housing bowl to the housing head using the original spanners. Do not over-tighten.
- Turn on the water mains.
- Wait for air purge from the vent valve, then screw and tighten the vent valve.
- Slowly turn on the water supply (tap) downstream of the installed unit and let the water flow for at least 5 minutes to flush the system before use.
Maintenance
Periodically clean the housing with cold water and a soft sponge.
Flush the system for 10 minutes after any period of non-use for more than two
days. For a period of non-use of two weeks or more, it may be necessary to
replace the cartridge.
Replace the cartridge after 3 months or when a drop in downstream water
pressure is observed.
WARRANTY INFORMATION
Blue Mountain Co guarantees this product for 12 months from the date of
purchase.
Under this warranty, we will replace the product or repair it free of charge.
Claims must be received by Blue Mountain Co
(info@bluemountainco.com.au) within 12
months of the date of purchase. The benefits conferred by this warranty are in
addition to all other rights and remedies available in law in respect to the
goods and services to which it relates. Our goods come with guarantees that
can not be excluded under the Australian Consumer Law.
You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Supported
A common misconception about collecting rainwater is that all you need is a
root, a tank, and some rain. His “tanking’ approach cannot always be relied on
to deliver the volume – or quality of water that you require. That is where we
can help.
With some thought, your rain harvesting system can provide you with cleaner
water and lots of it. Whether you’re completely reliant on tank water or want
to keep the garden green, our simple steps will help you achieve your goal.
The Rain Harvesting approach to rainwater collection involves using tested and proven products to make quality rainwater available for use in and around your property. You don’t need much to get started and you will be surprised how easy it is to get the most out of your rainwater system.
How can we help you?
DISCLAIMER This product specification is not a complete guide to product usage. Further information is available from Rain Harvesting Pty Ltd and from the Installation and Operating
Instructions. This specification sheet must be read in conjunction with the Installation and Operating Instructions and all applicable statutory requirement. Product specifications may change without notice. Rain Harvesting Pty Ltd
For more information or to find out how we can help, just give us a call on
+617 3248 9600
Or visit our website at
rainharvesting.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>