SOMOGYI PIR 04WH Motion Sensor Wall Instruction Manual
- June 9, 2024
- SOMOGYI
Table of Contents
SOMOGYI PIR 04WH Motion Sensor Wall
Before using the product for the first time, please ference. read The the
original instructions instructions for use were below written and in the
retain Hungarian them for language. later reor This mental appliance
capabilities, may or only lacking be in used by experience persons or with
know impaired edge, as well physical, as sensory children
from the age of 8, if they are under supervision or have been given
instruction have concerning understood use the Children of the hazards may
appliance only associated clean by a or with person perform use. user
responsible Children maintenance for should their not on safety be the and
allowed appliancetheyto
- passive infrared (PIR) sensor
- for operating lamps
- detecting adjustable distance: 12 light m
- sensitivity: detecting
The light for passive buildings, infra-red gardens, (PIR) garages, movement walkways detector etc. is It ideal saves to energy automatically because conlrol you can the set night the is desired on. The strength period of is the prolonged environment (the light lamp to block stays the on) if device the as device well as detects the period repeated while the movement lamp in the detected observed movement area ceases. before turning off. The switch-off period always starts when the last Within the maximum switched ll load motors values, such It is as not those only used capable in of fans. controlling Designed for lighting outdoor but is also use, it suitable features for IP44 switching protection.
CONTROLS
The device must be mounted so that the controls are on the bottom. TIME: approximately Switch-off 1 O seconds period and from 7 the minutes. last detected movement: adjustable between Se1 leaving It energy-saving on the area. minimum For fluorescent value walkway lighls if you it is selecting wan1 the recommended the lamp to the maximum to set switch a off adjustable longer as soon time, switch-off as but possible at period. least after For 5 minutes, is recommended. LUX: Strength of environment1 light: 3-2000 LUX During considerable the day, amount when of lighting energy. is not You can required, set light prevenls sensitivity turning on according the to lighs local thereby conditions. saving a Tum towards the control sun symbol towards if it the must moon be on the symbol in the if you twiligh1 only period want as to use well. the lamp in the dark, and
MOUNTING
The pictures showing the detection area guide you to choose 1he ideal mounting location: -rays sensitivity is greatest when the movement’s direction is perpendicular to the emitted IR a-typical pproximately height 12 is 2.5 mat m; <24 under ‘C optimal environment conditions, the temperature the maximum range of detection can be – if (e.g. the in difference in hotweatherduring1he temperature summer), between the 12 m moving range object may go and down ils to as environment little as is 6 m small
- pthe assing device car or can small occasionally animals be 1riggered by streaming ho1 air, gusls of wind, the engine of a
- if1he 1he device lamp’s can light also be sensor is 11iggered in by partial or movement full shadow during (e.g. 1he day when located under a roof or 1ree)
- it is recommended 1o ensure good visibility in the detection range
GETTING STARTED
Warning: contact Installation protection should regulations only be in force. performed by a specialist, in compliance with the safety
-
Unscrew the two screws fastening the back cover and remove the cover.
The cover can be wall-mounted via the two holes in 1he oppostte comers. -
Ccaubt leel ethcrotricu gpoh waefter ra pnudn scehcinugre tlyh eco runbnbeectr tphleu gth. reOen lyw imreask ien ath heo tleerm asin laalr.g Yoe aus ca nence puslsl athrye when pulling the wire through in order to avoid water trickling inside the device.
-
Fasten the device 1o the back cover already mounted on the wall.
-
After restoring power the detector is ready.
-
Perform various tesls to find the TIME and LUX settings you need.
-
You can change the observed zone by vertically adjusting the head
CARE Warning: Power off the motion detector prior to deaning it. Tcohneta smeninsaoUr owni.n dow may require deaning from time to time, depending on the degree of Use a soft, dry do1h to remove any stubborn deposils.
CONNECTION SHEME
TROUBLESHOOTING
Cause | Solution |
---|---|
Theswitched unit does not operate. | Check the motion detector and the unfs |
connections.
Check whether the switcred unit • malfurdioning.
Check whether the adjusted l hl sensiivity is app,T.l)riate
Low sensitivity.| Check whether something is obstructing the motion
detecto!s l’indoN, or rr rt requires cleaning.
The am ent temperature may be too h h.
Check whether there • an induction signal souroe in the
motion detectols sensng area. (e.g. electr’c motor)
Check the installationI-eight
Check whether the direction of motion detection e
appropriate.
Themotion detector does
not switch the unit off.
| Check whether there • a constant infrared signal source in
the motion detectols sen ng area.
Check whether the d<aay time • set to maximum.
Check that the mains voltage is 230VAC/50H.z
Check whether the temperature varies freqoontly in the
vicinrty of the sensor (e.g., due to air conditioner or heater).
WARNINGS
- Confirm tha1the appliance has not been damaged in transit
- The unit may only be mounted on surfaces of appropriate bearing capacity.
- tHeamnpdelera twuritehs , cahurem;i diptyro a1nedc tm foroismtu rep.h ysical shock, vibration, extremely low or high
- Must no1 be exposed to direct sunligh1 or heat.
- Wsuhnelignh itn(set.agll.e, udn odueldr tohce rsea, v1hees ).u nit should be mourned in a location away from direct
- Do not place near a fan, radiator or air vent.
- The detectols sensitivily grealy depends on the operating conditions.
- Tshhoec dke pvroictecte caionn b reeg inuslatatiollends . by a technician, following the applicable safety and electric
- reResqtouriereds. a short power-up period before starling to operate normally after electricity is
- Clean with a dry, soft doth; never use aggressive detergents.
- Make sure that the maximum load limit is not exceeded.
- Removing the device’s cover results in danger of electric shock.
- In case of malfunction, cut electricily and consult a technician.
Waste equipment must not be collected separately or dispOsed of with household waste because it may contain components hazardous to the environment or health. Used or waste equipment may be dropped off free of charge at the point oT Sale, or atany distributor which sells equipment or identical nature and function. Dispose of product at a facility specializing in the collection of electronic waste. By doing so, you will protect the environment as well as the health of others and yourself. If you have any questions, contact the local waste management organization. We shall undertake the tasks pertinent to the manufacturer as prescribed in the relevant regulations and shall bear any associated costs arising.
TECHNICAL PARAMETERS
- principle of operation: passive infrared (PIR) sensor
- detection angle: 180 radial
- optimum speed of motion detection: 0.6-1.5 m/s
- detection distance: max. 12 m (<24′ C)
- operating Time: min. 10 sec. t3 sec.; max. 7 min t2 sec.
- light sensitivity: 3-2000 LUX (adjustable)
- recommended installaton neignt: 1.8-2.5m
- operating temperature: -20-+40C
- operating humidity: 93% RH
- power supply (standby/on): 230 VAC/50 Hz (0.1 W/0.45 W)
- relay-switched power: 230 VAC/50 Hz
- incandescent light bulb: max. 1200W
- fluorescent light: max. 300 W
- motor: max. 150W
- Size: 85 x85x 95 mm
Meaning of lp44
Protected from the entry of solid objects larger that 1 mm. Protected from splashing water (from all directions).
Distributer za SLO: ELEMENTA ELEKTRONIKA d.o.o.
Cesta zmage 13A, 2000 Maribor Tel.: 05 917 83 22,
Fax: 08 386 23 64
Mail: office@elementa-e.si
www.elementa-e.si
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>