Humanscale Nova Desk Lamp Instruction Manual
- October 30, 2023
- Humanscale
Table of Contents
- Product Information
- Important Safety and Care Instructions
- Included Parts
- 10 Mounting Screws (For Wall Mount)|
- Tools Required
- Desktop Base Installation
- Optional Mounts
- Slatwall Mount Installation
- Wall Mount Installation
- Clamp Mount Installation
- User Interface Behavior
- Dimming
- Occupancy Sensor
- Deactivating the Sensor
- Activating the Sensor
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Assembly Instructions
Product Information
Power Consumption: 7 watts
Input Power: 24V, 0.75A
Dimming Range:14% – 100%
Lifespan: 50,000 hours (10 years)
Maximum Reach: Standard: 28.85″ / XL: 32.75″
Working Height: Standard: Lower Arm: 13.8″ Upper Arm: 13″ XL: Lower Arm:
15.8″Upper Arm: 15″
FCC Notice
Applies to USA
Model: N
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications made to this device that are not expressly approved by Humanscale may void the user’s authority to operate the equipment.
Innovation, Science and Economic Development Canada ICES-005 Compliance Notice:
CAN ICES-005 (B) / NMB-005 (B)
Important Safety and Care Instructions
Unplug from power source before cleaning.
Wipe clean with a soft damp cloth. Avoid amonia-based cleaners and
abrasives.
Do not expose power cord to liquids or high temperatures.
The external flexible cable or cord of this luminaire cannot be replaced; if
the cord is damaged, the luminaire shall be destroyed.
Avoid staring directly at light source.
The light source of this luminaire is not replaceable; when the light source
reaches its end of life the whole luminaire shall be replaced.
Included Parts
AC Adapter (Only included for USA/Canada)|
---|---
AC Adapter (Only included for Asia-Pacific/Oceania*)|
AC Adapter (Only included for EU/UK)|
10 Mounting Screws (For Wall Mount)|
Drywall Anchors (For Wall Mount)|
3mm Allen Wrench (For Wall Mount and Slatwall Mount)|
*Only use the plug types for countries designated above.
Note: This configuration is designated for Hong Kong, but not China. For
a China CCC certified model, please contact our customer service line.
Tools Required
For Wall Mount
Pencil|
---|---
5/16” (7.9mm) Drill Bit for Drywall
or
1/8” (3.2mm) Drill Bit for Hardwood|
Drill with #2 Philips
Head Driver Bit|
Desktop Base Installation
Insert the Light Body into the Destop Base.
Optional Mounts
For the Slatwall Mount, Wall Mount, and Clamp Mount, remove the rotational stop collar (A) before installing the Light onto the Mount.
Slatwall Mount Installation
Using a 3 mm allen wrench, adjust the universal clamp bracket (B) to align with the openings on the slatwall, place the mount on the slatwall, and then tighten by turning the bolt clockwise.
Wall Mount Installation
-
Using the Wall Mount Bracket (C), trace the mounting holes onto the desired location with the arrow pointing upward.
-
Secure the Bracket to the wall with the provided hardware.
• If mounting to drywall, use a 5/16”(7.9mm) drill bit for drywall anchor pilot holes.
• If mounting to hardwood, use a 1/8”(3.2mm) drill bit for the #10 screw pilot holes. -
Hook the Wall Mount onto its Bracket and tighten by turning the bolt clockwise using the 3mm allen wrench.
Clamp Mount Installation
Condition 1:
If installing onto a worksurface that is 2” (51mm) or less, orient the
attachment bracket as depicted.
Condition 2:
If installing onto a worksurface that is greater than 2” (51mm), orient the
attachment bracket as depicted.
Note:
The clamp mount can easily be converted for use on thicker work-surfaces by
disassembling its components, rotating the L Bracket (D), and reassembling.
User Interface Behavior
To turn the light ON and OFF, lightly tap the touchpad. The luminaire will remember the last brightness level it was set to.
Dimming
To increase or decrease brightness, slide finger up or down on the touchpad.
Occupancy Sensor
Nova is equiped with an occupancy sensor that detects when the user is within range (1 meter), and turns on automatically. It will turn off after 15 min of user vacancy.
Deactivating the Sensor
Touch and hold the center of the touchpad for 5 seconds. The luminaire will flash and the Indicator LED will turn orange.
Activating the Sensor
Touch and hold the center of the touchpad for 5 seconds. The luminaire will flash and the Indicator LED will turn white.
Humanscale Corporation
1114 6th Ave. 15th Floor
New York, NY 10036
www.humanscale.com
For our terms and conditions please go to
https://www.humanscale.com/about/legal-information/terms-conditions.cfm
© 2020 Humanscale Corporation. The text and artwork are copyrighted materials.
All rights reserved. The Humanscale mark and logo are trademarks of Humanscale
Corporation and are registered in the United States and certain other
countries.
02/23/2022
GT -NPD-AI-3789-001-R02
North America: +1 800 400 0625
Europe: +353 (0)1 858 0910
Asia Pacific: +852 2581 0570