Enerdrive ePOWER 400W True Sine Wave Inverter
Please Keep This Manual For Future Reference
For safe and optimum performance, the Enerdrive Gen2 Inverter must be used
properly. Carefully read and follow all instructions and guidelines in this
manual and give special attention to the CAUTION and WARNING statements.
Disclaimer While every precaution has been taken to ensure the accuracy of the contents of this guide, Enerdrive assumes no responsibility for
Important Please be sure to read and save the entire manual before using
your Enerdrive Gen2 Inverter. Misuse may result in damage to the unit and/or
cause harm or serious injury. Read manual in its entirety before using the
unit and save manual for future reference.
Product Numbers – Gen2 Inverter Series
EN1104S-12V Gen2 Inverter 400W 12V
Enerdrive Gen 2 Inverter Owner’s Manual Rev. 1.4. This Manual applicable to
all units with serial number prefix EPI.
Notice of Copyright
Enerdrive Gen2 Inverter owner’s manual © 2021 Enerdrive. All rights reserved. No part of this document may be reproduced in any form or disclosed to third parties without the express written permission of Enerdrive Pty Ltd, P.0. Box 9159, Wynnum Plaza, Queensland, Australia 4178. Enerdrive reserves the right to revise this document and to periodically make changes to the content hereof without obligation or organization of such revisions or changes, unless required to do so by prior arrangement.
Exclusions For Documentation And Product Usage
Unless specifically agreed to in writing, Enerdrive Pty Ltd: makes no warranty
as to the accuracy, sufficiency or suitability of any technical or other
information provided in its manuals or other documentation Assumes no
responsibility or liablity for losses, damages, costs or expenses, whether
special, direct, indirect, consequential or incidental, which might arise out
of the use of such information. The use of any such information will be
entirely at the user’s risk Reminds you that if this manual is in any language
other than English although steps have been taken to maintain the accuracy of
the translation, the accuracy cannot be guaranteed
Makes no warranty, either expressed or implied, including but not limited to
any implied warranties of merchantability or fitness for a particular purpose,
regarding these Enerdrive products and makes such Enerdrive products available
solely on an “as is”basis Shall in no event be liable to anyone for special,
collateral, incidental, or consequential damages in connection with or arising
out of purchase or use of these Enerdrive products. The sole and exclusive
liability to Enerdrive, regardless of the form of action, shall not exceed the
purchase price of the Enerdrive products described here in.
Enerdrive Gen2 Inverter INTRODUCTION
The Enerdrive Gen2 Inverter is a state-of-the-art, easy-to-use inverter designed for use in a caravan, 4WD or commercial vehicle. With a 400W power output and 12V input, this unit can power many AC-powered appliances anywhere. Thank you for purchasing the Enerdrive Gen2 lnverter. With our state-of-the- art, easy-to-use design, this product will offer you reliable service for providing AC power for your home, boat, caravan, 4WD or commercial vehicle. The Enerdrive Gen2 Inverter can run many AC-powered appliances when you need AC power anywhere. This manual will explain how to use this unit safely and effectively. Please read and follow these instructions and precautions carefully.
IMPORTANT SAFETY INFORMATION:
This section contains important safety information for the Enerdrive Gen2
Inverter. Each time, before using the Enerdrive Gen2 Inverter, READ ALL
instructions and cautionary markings on or provided with the inverter, and all
appropriate sections of this guide. The Enerdrive Gen2 Inverter contains no
user-serviceable parts. See the Warranty section for how to handle product
issues.
WARNING: FIRE AND/OR CHEMICAL BURN HAZARD
- Do not cover or obstruct any cooling fins and/or install in a zero-clearance compartment.
WARNING: SHOCK HAZARD. KEEP AWAY FROM CHILDREN!
- Avoid moisture ingress. Never expose the unit to snow, water, etc
- Unit provides 230 VAC, treat the AC output socket the same as regular wall AC sockets at home..
WARNING: EXPLOSION HAZARD!
- DO NOT use the Enerdrive Gen2 Inverter in the vicinity of flammable fumes or gases (such as gas bottles or large engines).
- AVOID covering the ventilation openings. Always operate unit in an open area.
- Prolonged contact to high heat or freezing temperatures will decrease the working life of the unit.
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR SERIOUS INJURY
- When working with electrical equipment or lead acid batteries, have someone nearby in case of an emergency.
- Wear eye protection and gloves.
- Avoid touching your eyes while using this unit.
- Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If this occurs, cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention.
- Keep unit away from moist or damp areas.
- Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short circuit which goes through the battery or another electrical tool that may create an explosion.
LIMITATIONS OF USE
- Do not use in connection with life support systems or other medical equipment or devices.
- Inverter is not to be used by persons with reduced physical or mental capabilities or lack of knowledge and experience. Not to be operated or used by children.
Product Description
The Enerdrive Gen2 Inverter package includes the items list below.
- Gen2 Inverter
- Owner’s manual
- DC Input cable accessories
Features
- 400W power output
- 12V input
- Status indicator & warning/fault alarm
- Remote switch (optional) connection
- Ignition start function
- 5-year warranty
Understanding the unit features:
Image below shows unit features:
Product Usage Instructions
Before using the Enerdrive Gen2 Inverter, it is important to carefully read and follow all instructions and cautionary markings provided with the inverter, as well as all appropriate sections of the user manual. Failure to do so may result in damage to the unit and/or cause harm or serious injury.
Installing the Inverter System
Before installing the inverter system, be sure to prepare all necessary materials. Once ready, follow these steps:
- Install the inverter in a safe location that is out of reach of children and pets.
- Connect the inverter’s DC input to your vehicle’s battery.
WARNING: ELECTRICAL SHOCK HAZARD
The unit On/0ff switch does not disconnect the DC power from the battery. To
turn of the DC power to the inverter either remove the main DC fuse or swtich
off the circuit breaker to disconnect the DC power from the inverter before
working on any circuits connected to the unit. Failure to follow these
instructions can result in death or serious injury.
CAUTION Reversing the DC Input terminal will damage the unit and cannot
be repaired. Damage caused by reverse polarity connection is not covered by
the warranty.
WARNING Enerdrive recommends that all wiring be done by a certified
technician or electrician to ensure adherence to the applicable electrical
safety wiring regulations and installation codes. Failure to follow these
instructions can damage the unit and could also result in personal injury or
loss of life.
CAUTION
- Before Beginning Your Unit Installation, Please Consider The Following:
- The unit should be used or stored in an indoor area away from direct sunlight, heat, moisture or conductive contaminants. Do not install the Gen2 Inverter in corrosive environments.
- When placing the unit, allow a minimum of 75mm of space around the unit for optimal ventilation.
Material Preparation for Installation
Typical Wiring block diagram of the Enerdrive Inverter:
Battery Bank
The use of a deep cycle battery is highly recommended for power inverter applications For battery capacity, you need to identify how long you wish to operate the load(s). Enerdrive does recommend that you purchase as much battery capacity as possible. See more on “Estimated Run time and Load” in Section 6.
Fuse or Circuit Breaker:
- A DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required.
- Select a fuse or circuit breaker with 60 A/16V minimum rating for the 12V DC Input Inverter(s).
- Based on the size of the battery bank chosen, determine the overall short circuit current rating of the battery bank from the battery manufacturer. The fuse or circuit breaker chosen has to be able to withstand the short circuit current that may be generated by the battery bank.
DC Input Cable:
- The use of low-resistance wire is required for all the DC connections between the inverter and the battery bank.
- Use a minimum 16mm2 cable with a maximum length of 1.5m for a 12V DC inverter.
Inverter Installation:
- Choose an appropriate mounting location.
- For indoor use only, the orientation of the unit can be mounted in any direction except with the DC Input panel facing downwards.
- For RV installation, the unit has to be mounted horizontally.
- Use mounting template on the following to mark the positions of the mounting screws.
- Drill the 4 mounting holes and place the inverter in position and fasten the inverter to the mounting surface.
Inverter DC Input Connection
CAUTION Reversing the DC Input terminal will damage the unit and cannot be repaired. Damage caused by reverse polarity connection is not covered by the warranty.
Hardwired Direct Connection:
- Attach a positive (+) DC terminal (red) cable on the power inverter.
- Attach a negative (-) DC terminal (black) cable on the power inverter.
- Tighten the nut on each DC terminal.
- Connect the other end of the positive DC input cable to one of the terminals of the fuse holder or circuit breaker switch.
- Connect a DC positive input cable between the other terminals of the fuse holder or circuit breaker switch to the battery-positive terminal.
- Connect the DC negative cable from the inverter to the negative post of the battery.
- Install the selected fuse to the fuse holder or switch on the circuit breaker.
- Unit is ready for use.
12v Lighter Plug Connection:
- Attach the red ring-type connector to the positive (+) DC terminal (red) on the power inverter.
- Attach the black ring type connector to the negative (-) DC terminal (black) on the Power inverter.
- Tighten the nut on each DC terminal.
- Insert the light plug of this cable to the fused 12V lighter plug socket.
- Make sure your load is not greater than 120W while using the 12V lighter plug.
Connect unit with optional accessories using the Battery clips cable:
- Attach the red ring-type connector to the positive (+) DC terminal (red) on the power inverter.
- Attach the black ring type connector to the negative (-) DC terminal (black) on the Power inverter.
- Attach the negative (black) clip to the negative (-) battery terminal.
- Attach the positive (red) clip to the load side of the fuse or circuit breaker of the 12V battery bank as indicated on “Typical Wiring block diagram of the Power Inverter” on.
- Unit is ready for use.
CAUTION: Please be sure all the connections are tight before the use of the unit.
Testing the Power Inverter
Before using the power inverter, it is important to test it to ensure proper operation. Follow these steps:
- Turn on the power inverter.
- Plug in a device that requires AC power.
- Ensure that the device receives power.
- Turn unit on by using the On/Off button on the unit. The ‘Power light turns on indicating the Enerdrive Power Inverter is ON. AC output is now available.
- Plug in a small AC load like a 25W table lamp or small appliance to the AC socket to verify AC is available.
- The unit is successfully installed and functioning properly.
Unit Operation
To turn the unit on or off, use the power switch. The status indicator will show the current state of the unit. The warning/fault alarm will sound if there is an issue with the unit. You can connect a remote switch (optional) to control the unit from a distance. You can also use the ignition start function to automatically turn on the unit when the vehicle is started.
WARNING: RISK OF EQUIPMENT DAMAGE
- Do not connect an AC power source like utility power or generator to the unit AC outlets.
Turn ON and OFF the unit
- Press the power switch to turn the unit on. “Power” indicator LED will turn green.
- ‘Power’ indicator will turn green.
- AC Output is available at the AC output socket.
Understanding the ‘Status’ indicator & the unit warning & fault alarm Status’ indicator:
- Illuminated in green indicates unit is ON. AC is available at the AC Output Socket.
- Illuminated in green and alarm is beeping once every 2 second indicates a warning signal from the unit. The unit is close to shutdown with one or more of the following warning conditions:
- Over Temperature Warning: Unit internal temperature is high. Unit requires better ventilation
- DC Over Voltage Warning: DC Input Voltage is high and close to the unit over-voltage shutdown limit. Check the battery voltage.
- DC Under Voltage Warning: DC Input Voltage is low and is close to the unit under voltage shutdown limit. Check battery voltage or battery connection.
Illuminated in red and alarm is beeping once every second indicates AC Output has shut down due to the following conditions:
- Over Temperature Shutdown: Reduce the AC load connected to the unit and provide more ventilation to the unit. AC Output will automatically restart when the internal temperature cools down.
- DC Over Voltage Shutdown / DC Under Voltage Shutdown: Check the battery voltage. In the first 30 seconds, AC Output will resume when battery voltage is within the unit’s operating range. If the battery voltage shutdown condition is ignored, the unit will switch OFF completely after 30 seconds and to restart the unit, use the green “On/Off’ button after the battery voitage has been corrected.
- AC Output Overload Shutdown: Check AC Load connected to the unit. AC Output is short-circuited or AC Power draw by the load is beyond the unit’s limit. The indicator and alarm will beep for approx 30 seconds before it switched OFF completely. Restart the unit using the green ‘On/Off button is required after the AC Load condition is corrected.
Understanding the fan operation
The fan on the unit will automatically turn on when it senses the internal
temperature of the unit reach its preset level.
AC Load on Power Inverter
Although the Power Inverter can provide high surge power, some appliances may
still trigger on the inverter protection system. A higher power inverter is
required for those appliances.
Remote Switch (optional) Connection:
The unit comes with a Remote port and an optional ‘Remote Switch’ accessory
(EN1104-REM) can be used to turn unit On and OFF remotely. To install the
‘Remote Switch’, just connect the switch’s RJ12 plug to the RJ12 ‘Remote’ port
located on the Front AC panel of the inverter. Please note polarity when
connecting the plug.
Use of the Ignition Start Function on unit:
An ‘Ignition Start’ port is located on the Front AC Panel of the unit using a
¼” width spade terminal. This port is used for turning the unit On and OFF
using a +12V signal. An insulated female connector is required to connect to
the port. Connecting to +12V will turn ON the unit and removing the +12V
signal will turn OFF the unit.
Estimate Run time on Load
The following run times are an estimate based on using a 12V-120AH battery
bank for 12V systems. Actual run time may vary.
Troubleshooting
If you encounter issues with the Enerdrive Gen2 Inverter, consult the troubleshooting section of the user manual for assistance. If the issue persists, contact ENERDRIVE PTY LTD for support.
SPECIFICATION
Warranty
The Enerdrive Gen2 Inverter comes with a 5-year warranty. See the warranty section of the user manual for more information.
5 Year Warranty
In the unlikely event that a technical issue arises with an Enerdrive product,
customers are encouraged to initially contact the Enerdrive Support Team on
1300 851 535 or support@enerdrive.com.au
for immediate and efficient expertise and first class product support.
Important Note: Consumer Protection
If you have purchased your product in Australia, you should be aware that:
This warranty is provided in addition to other rights and remedies held by a
consumer at law. Our goods come with guarantees that cannot be excluded under
the Australian Consumer Law. You are entitled to a replacement or refund for a
major failure and for compensation for any other reasonably foreseeable loss
or damage. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a
major failure.
Enerdrive warrants that its Products will be free from defects in materials
and workmanship (subject to limits, and in normal conditions, as described in
the complete Enerdrive Warranty Policy) for up to 5 years from the date of
purchase.
For full terms, conditions and claim process, refer to the Enerdrive website.
https://enerdrive.com.au/warranty/
ENERDRIVE PTY LTD
P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178 Ph: 1300 851 535 /
Fax: 07 3390 6911
Email: support@enerdrive.com.au
Web: www.enerdrive.com.au
More information https://www.caravansplus.com.au
References
- Enerdrive Independent Power Solutions - ENERDRIVE | DOMETIC
- Caravan Accessories & RV Parts Australia - CaravansPlus
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>