RED LION RL-MP25A Utility Pump Owner’s Manual

June 15, 2024
RED LION

RED LION logo

OWNER’S MANUAL
RL-MP25A Utility Pump

RED LION RL-MP25A Utility Pump

RL-MP25A Utility Pump

The RL-MP25A utility pump is ideal for general water transfer applications and household water removal in places like basements, crawl spaces, rooftops, and other areas where automatic operation is required.This pump activates in three minute intervals to detect if water is present. If water is present, pump continues to run until water is removed.
This product is covered by a Limited Warranty for a period of 5 years from the date of original purchase by the consumer. For complete warranty information, refer to www.redlionproducts.com, or call Technical Support for a printed copy.

Specifications

Model| Item Number| HP| Amps| Discharge| Intake| Cord Length
ft (m)| Weight
lb (kg)
---|---|---|---|---|---|---|---
RL-MP25A| 14942735| 4-Jan| 2| 1-1/4″ MNPT
3/4″ GHT| Screened
Bottom| 10 (3.05)| 7.5 (3.4)

Flow Rate

Gallons (Liters) per Hour at Height| Shut Off
ft (m)
---|---
0 ft (0 m)| 5 ft (1.5m)| 10 ft (3.0 m)| 15 ft (4.6 m)
2200 (8328)| 1920 (7268)| 1440 (5451)| 900 (3407)| 22 (6.7)

SAFETY INSTRUCTIONS

Specifications

This equipment should be installed and serviced by technically qualified personnel who are familiar with the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with national and local electrical and plumbing codes and  within Red Lion recommendations may result in electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product’s application, limitations, and potential hazards. Read and follow instructions carefully to avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional operating instructions and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following hazards:

DANGER
Risk of death, serious injury, or property damage due to explosion, fire, or electric shock.

  • Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
  • Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
  • Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface or in water until the unit is unplugged or electrically disconnected.
  • When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electrically disconnected.

WARNING

High voltages capable of causing severe injury or death by electrical shock are present in this unit.

  • To reduce risk of electrical shock, disconnect power before working on or around the system. More than one disconnect switch may be required to de-energize the equipment before servicing.
  • Be certain that this pump is connected to a circuit equipped with a ground fault circuit interrupter (GFCI) device.
  • Wire pump system for correct voltages.
  • Check local electrical and building codes before installation. The installation must be in accordance with their regulations as well as the most recent National Electrical Code (NEC), Occupational Safety and Health Act (OSHA), and Canadian Electrical Code (CEC).
  • This product is supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of electric shock, be certain that it is connected only to a properly grounded grounding-type receptacle. Do not remove the third prong from the plug. The third prong is to ground the pump to help prevent possible electric shock hazard. Do not use an extension cord.
  • Check electrical outlets with a circuit analyzer to ensure power, neutral, and ground wires are properly connected. If not, a qualified, licensed electrician should correct the problem.
  • Be sure the electrical connection cannot be reached by rising water. Under no circumstances should the junction box be located where it may become flooded or submerged by water.

CAUTION
Risk of bodily injury, electric shock, or equipment damage.

  • This equipment must not be used by children or persons with reduced physical, sensory or mental abilities, or lacking in experience and expertise, unless supervised or instructed. Children may not use the equipment, nor may they play with the unit or in  the immediate vicinity.
  • Do not use this pump for pumping any liquid intended for human consumption.
  • Equipment can start automatically. Always unplug the pump power cord and disconnect the electrical power before servicing the pump or switch. Lockout-Tagout before servicing equipment.
  • An inoperative or malfunctioning pump could lead to flooding, resulting in personal injury or property damage.
  • In applications where property damage and/or personal injury might result from an inoperative or leaking pump due to power outages, discharge line blockage, or any other reason, an automatic back-up system and/or an alarm should be installed.
  • Do not run the pump dry. If run dry, the surface temperature of the pump will rise to a high temperature that could cause skin burns if touched, and will cause serious damage to the pump.
  • Do not oil the motor. The pump’s motor housing is sealed, and contains a high-grade dielectric oil for heat transfer and lifetime lubrication. Use of other oils could cause serious electric shock and/or permanent damage to the pump.
  • The pump has been evaluated for use with water only. Pump should only be used with liquids compatible with pump component materials. If the pump is used with liquids incompatible with the pump components, the liquid can cause failure to the  electrical insulation system resulting in electrical shock.
  • Operation of this equipment requires detailed installation and operation instructions provided in this manual for use with this product. Read entire manual before starting installation and operation. End User should receive and retain manual for future use.
  • Keep safety labels clean and in good condition.

NOTICE
Risk of damage to pump or other equipment.

  • Do not use this pump for pumping sea water, beverages, acids, chemical solutions, or any other liquid that pro- motes corrosion as this can result in damage to the pump.
  • Do not run pump dry. For optimal cooling and to prolong the motor life, the liquid level being pumped should normally be above the top of the pump housing.
  • This pump is not suitable for pond applications.

INSTALLATION

Physical Installation

WARNING
Risk of severe injury or death by electrical shock.

  • Always disconnect the electrical power before touching the pump or discharge.

NOTICE
Risk of damage to pump or other equipment.

  • Support pump and piping when assembling and when installed. Failure to do so may cause piping to break, pump to fail, motor bearing failures, etc.
  1. Attach hose or other plumbing to pump discharge.
    NOTE: The pump discharge is 1-1/4 inches NPT and the included adapter is 3/4 inches GHT.

  2. Place pump in an upright position on a hard, level surface in the water reservoir.
    • Never place pump directly on clay, earth, or gravel surfaces.
    • Secure the pump so the starting torque does not cause the pump to contact anyone or anything.

  3. Direct and secure the open hose or other plumbing end to desired water depository.

Electrical Connections
WARNING

High voltages capable of causing severe injury or death by electrical shock are present in this unit.

  • To reduce risk of electrical shock, disconnect power before working on or around the system. More than one disconnect switch may be required to de-energize the equipment before servicing.
  • The flexible jacketed cord assembly mounted to the pump must not be modified in any way, with the exception of shortening the cord to fit into a control panel. Any splice between the pump and the control panel must be made within a junction box  mounted outside of the basin and comply with the National Electrical Code (NEC).
    Employ a licensed electrician.
  1. Connect the power cord to a constant source of power matching the pump nameplate voltage.
    • Connect the pump to its own circuit, with no other electric receptacles or equipment in the circuit.
    • Ensure that the fuses or circuit breaker are of ample capacity in the electrical circuit.
    • Plug pump into a properly grounded receptacle.

  2. Control power to the pump by plugging and unplugging the cord.

OPERATION

Storage

The pump automatically turns on every three minutes. It will run for 5 seconds to check if water is present. If water is present, the pump will run continuously until the water reaches the shut-off level. If no water is present, the pump will shut off for another three minutes.
IMPORTANT: If the drainage area refills at a quicker rate than the RL- MP25A’s operation cycle, change to a pump with a float switch mechanism.
NOTE: To start the pump manually, disconnect the cord from the power source, wait 5 seconds, then reconnect.

MAINTENANCE

WARNING
Risk of severe injury or death by electrical shock, high temperatures, or pressurized fluids.

  • Always unplug the pump power cord in addition to removing the fuse or shutting off the circuit breaker before working on the pump or switch.
  • Let pump cool for a minimum of 2 hours before attempting to service. Submersible pumps contain oil that becomes pressurized and hot under normal operating conditions.

NOTICE
Risk of damage to pump or other equipment.

  • This unit is permanently lubricated. Oiling is not required. Do not open the sealed portion of the unit or remove housing screws.
  • Do not remove the motor housing cover, impeller, or seals. Warranty is void if the motor housing cover, impeller, or seals have been removed. Repairs on the motor or impeller require special tools.

Storage

  1. Disconnect pump from the power source.
  2. Remove the pump from the discharge plumbing.
  3. Drain all liquid from the pump and allow it to dry thoroughly.
  4. Store pump in a warm, dry place.

MAINTENANCE

Troubleshooting

Problem Probable Causes Corrective Action

Pump does not turn
on| Pump not plugged in| Plug in pump.
Circuit breaker off or fuse removed| Turn on circuit breaker or replace fuse.
Defective motor| Replace pump.
Pump not given enough operation time| Allow the pump to operate for at least 5 minutes.
The pump must sit for 3-5 minutes before turning
on to check for water.
Pump turns off aftestarting| Incorrect voltage| Check power supply.
Excessive flow restriction| Remove kinks and other hose restrictions.
Pump is air locked| Release air from discharge.
Pump will not shut off| Pump is air locked| Release air from discharge.
Liquid inflow matches pump capacity| Larger pump required.
Impeller or discharge pipe is clogged| Pull pump and clean. Check pipe for scale or corrosion.
Pump runs but doesnot discharge liquid| Lift too high for pump| Check rated pump performance.
Inlet to impeller plugged| Pull pump and clean.
Pump is air locked| Remove pump and clean air bleed hole.
Pump does not
deliver rated capacity| Lift too high for pump| Check rated pump performance.
Low voltage, speed too slow| Check that supply voltage matches nameplate rating.
Impeller or discharge pipe is clogged| Pull pump and clean. Check pipe for scale or corrosion.
Impeller wear due to abrasives| Replace pump.

RED LION RL-MP25A Utility Pump - Qr Code

For technical assistance, parts, or repair, please contact:
888.885.9254 | redlionproducts.com
998489 Rev. 001 08/22

RED LION logo

Copyright © 2022, Franklin Electric, Co., Inc. All rights reserved.

Documents / Resources

| RED LION RL-MP25A Utility Pump [pdf] Owner's Manual
RL-MP25A Utility Pump, RL-MP25A, Utility Pump, Pump
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals