Enerdrive ePOWER Industrial Battery Charger Owner’s Manual

June 6, 2024
Enerdrive

Enerdrive ePOWER-logo1

Enerdrive ePOWER Industrial Battery Charger-

Operation & Owner’s Manual
24V, 36V & 48V Models
Rev: 1.6

PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
For safe and optimum performance, the Enerdrive ePOWER Industrial Battery Charger must be used properly. Carefully read and follow all instructions and guidelines in this manual and give special attention to the CAUTION and WARNING statements.
Disclaimer
While every precaution has been taken to ensure the accuracy of the contents of this guide, Enerdrive assumes no
Important
Please be sure to read and save the entire manual before using your Enerdrive ePOWER Industrial Battery Charger. Misuse may result in damage to the unit batteries and/or cause harm or serious injury. Read the manual in its entirety before using the unit and save the manual for future reference.

Product Numbers – ePOWER Industrial Battery Charger Series

EPI-2430 ePOWER Industrial Battery Charger 24V / 30Amp
EPI-3620 ePOWER Industrial Battery Charger 36V / 20Amp
EPI-4815 ePOWER Industrial Battery Charger 48V / 15Amp
EPI-4835 ePOWER Industrial Battery Charger 48V / 35Amp
EPI-4860 ePOWER Industrial Battery Charger 48V / 60Amp

ePOWER Industrial Battery Charger Owner’s Manual 1.6. This manual applies to all units with serial numbers prefix EPI.

Service Contact Information
ENERDRIVE PTY LTD
P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178
Ph: 1300 851 535 / Fax: 07 3390 6911
Email: sales@enerdrive.com.au | Web: www.enerdrive.com.au

NOTICE OF COPYRIGHT

Enerdrive ePOWER Industrial Battery Charger owner’s manual © 2020 Enerdrive. All rights reserved. No part of this document may be reproduced in any form or disclosed to third parties without the express written permission of Enerdrive Pty Ltd, P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178. Enerdrive reserves the right to revise this document and to periodically make changes to the content hereof without obligation or organization of such revisions or changes, unless required to do so by prior arrangement.

Exclusions For Documentation And Product Usage

Unless specifically agreed to in writing, Enerdrive Pty Ltd: makes no warranty as to the accuracy, sufficiency, or suitability of any technical or other information provided in its manuals or other documentation

Assumes no responsibility or liability for losses, damages, costs, or expenses, whether special, direct, indirect, consequential, or incidental, which might arise out of the use of such information. The use of any such information will be entirely at the user’s risk

Reminds you that if this manual is in any language other than English although steps have been taken to maintain the accuracy of the translation, the accuracy cannot be guaranteed

Makes no warranty, either expressed or implied, including but not limited to any implied warranties of merchantability or fitness for a particular purpose, regarding these Enerdrive products and makes such Enerdrive products available solely on an “as is” basis

Shall in no event be liable to anyone for special, collateral, incidental, or consequential damages in connection with or arising out of purchase or use of these Enerdrive products. The sole and exclusive liability to Enerdrive, regardless of the form of action, shall not exceed the purchase price of the Enerdrive products described herein

INTRODUCTION

Thank you for purchasing the Enerdrive ePOWER Industrial Battery Charger. With our state of the art, easy to use design, this product will offer you reliable service for providing a multistage battery charger to charge the different types of batteries you have installed in applications such as electric vehicles, forklifts, floor cleaning machines, golf carts, and electric mobility scooters. This manual will explain how to use this unit safely and effectively. Please read and follow these instructions and precautions carefully.

IMPORTANT SAFETY INFORMATION:

This section contains important safety information for the Enerdrive ePOWER Industrial Battery Charger. Each time, before using the Enerdrive ePOWER Industrial Battery Charger, READ ALL instructions and cautionary markings on or provided with the battery charger, and all appropriate sections of this guide. The Enerdrive ePOWER Industrial Battery Charger contains no user- serviceable parts. Opening up the charger will void the product warranty. See the Warranty section for how to handle product issues.

WARNING
FIRE AND/OR CHEMICAL BURN HAZARD

  • Do not cover or obstruct any cooling fins and/or install in a zero-clearance compartment.

WARNING

SHOCK HAZARD. KEEP AWAY FROM CHILDREN!

  • Avoid moisture ingress. Never expose the unit to snow, water, etc.

WARNING: EXPLOSION HAZARD!

  • DO NOT use the Enerdrive ePOWER Industrial Battery Charger in the vicinity of flammable fumes or gases (such as gas bottles or large engines).
  • AVOID covering the cooling fins. Always operate the unit in an open and well-ventilated area.
  • Prolonged contact to high heat or freezing temperatures will decrease the working life of the unit.

WARNING

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR SERIOUS INJURY

  • When working with electrical equipment or lead-acid batteries, have someone nearby in case of an
  • Study and follow all the battery manufacturer’s specific precautions when installing, using, and servicing the battery connected to the charger.
  • Wear eye protection and gloves.
  • Avoid touching your eyes while using this unit.
  • Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If this occurs, cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention.
  • Batteries produce explosive gases. DO NOT smoke or have an open spark or fire near the system.
  • Never attempt to re-charge a damaged, frozen, or non-rechargeable battery.
  • Keep the unit away from moist or damp areas.
  • Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short circuit which goes through the battery or another electrical tool that may create an explosion.
  • Battery charger must be plugged into an earthed and Australian Standards compliant mains supply. If the unit’s power cable is damaged, replace the cable immediately.

LIMITATIONS OF USE

  • Do not use in connection with life support systems or other medical equipment or devices.
  • The charger is not to be used by persons with reduced physical or mental capabilities or lack of knowledge and experience. Not to be operated on or used by children.

** WARNING**

  • Enerdrive recommends that all wiring be done by a skilled technician to ensure adherence to the best practice standards for onboard DC electrical installations. Failure to follow these instructions can damage the unit and could also result in personal injury or loss of life.

** CAUTION**
• Before Beginning Your Unit Installation, Please Consider The Following:
• The unit should be used or stored in an indoor area away from direct sunlight, heat, moisture, or conductive contaminants. Do not install the ePOWER Industrial Battery Charger in corrosive environments.
• When placing the unit, allow a minimum of 75mm of space around the unit for optimal ventilation.

PRODUCT DESCRIPTION

The Enerdrive ePOWER Industrial Battery Charger package includes the items listed below.

  • ePOWER Industrial Battery Charger
  • IEC 240Vac Power Lead
  • Waterproofing grommet for Power Lead
  • Owner’s manual

OPERATION ILLUSTRATION LED Indicators and Fault Signals

LED Indicators during startup:

In order to find out the installed charging profile in the unit, please follow the steps below.

  1. Make sure the DC cables are not connected to the battery.
  2. Connect the AC input to the charger and switch it on.
  3. The charger LED display panel will indicate the battery charge algorithm profile installed.

LED Indicators and Digital Display:

Charger will enter charging model when connecting to battery & AC input cable. The digital display on the front panel will show in turn: AC XXX (Current AC input voltage), CPU X.XX (corresponding software version number), b**(Current charging profile code).

To change the charging profile, press & hold the Select button for 5 seconds, then press the Select button to choose the desired profile. Once selected, press & hold the Select key for 5 seconds, and the charging profile selection will be completed.

To start EQ mode, press & hold the Select button for 10 seconds, and the display will show EQ mode. The next charging cycle will go into EQ mode. If you want to quit the EQ mode, hold the Select button for 10 seconds. When the display shows OFF, the charger will quit the EQ mode.

Common Mode (Default) & BMS Mode:

A: The charger enters BMS mode when being connected to the lithium-ion battery through Can Bus; B: For safety reasons, the charger will flash “bnS” if being reconnected to a Lead-acid battery under a BMS mode;

C: The charger will only charge the Lead-acid type battery again if we refresh the charger through a USB port with the desired lead-acid battery charging profile via USB drive.

Charging Status Indicator and Status Display

  • % Capacity Percentage Indicator: Display shows charging percentage. e.g. 10 20 30…100 (%)
  • V Charging Voltage Indicator: Display shows charging voltage. e.g. 24.0 (V)
  • A Charging Current Indicator: Display shows charging voltage. e.g. 36.0 (V)

Additional Battery Voltmeter Function

  • B Battery Voltage Indicator. To check battery voltage, disconnect charger AC input and press the “Select” button for 1 second. Display shows battery voltage. e.g. 24.0 (V).

Battery Capacity Indicators:

Enerdrive ePOWER Industrial Battery Charger-table

LED will be showing Battery Charging Profile as below:

LED 1 LED 2 (100% Indicator) LED 3 (75% Indicator) LED 4 (50% Indicator)
Algorithm 30+ Algorithm 20+ Algorithm 10+ Algorithm 1 – 9

For example;

lithe charging profile has been selected to #35, LED 1 will be on to represent the charging profile is 30, and LED 4 will blink 5 times to indicate algorithm

35, while LED 2 and LED 3 will remain off.

if the charging profile has been selected to #18, LED 3 will be on to represent the charging profile is 10, and LED 4 will blink 8 times to indicate algorithm #18, while LED 1 and LED 2 will remain off.

Connecting the Cables:

Enerdrive ePOWER Industrial Battery Charger-Cables

  1. Connect to the positive terminal of the battery
  2. Connect to the negative terminal of the battery / BTS-
  3. Connect to the BTS+
    4,5,6:        Interlock Cable (4,6: NO the interlock cables will form an open circuit withno voltage. 5,6: NC The interlock cable will form a short circuit with no voltage).

7. Connect CANBUS or LED light wire (optional function).

Warning: Assure the battery connection cable is well connected with the charger before it is connected to the battery. Otherwise, the battery short circuit may occur and cause personal injury or damage to the battery.

WARNING

  • Please make sure the battery connection cables are correctly connected to the charger terminals before operating the charger

WARNING

  • Please make sure the battery connection cables are correctly connected to the charger terminals before operating the charger

Images on the previous page refer to EPI-2430, EPI-3620, EPI-4815 & EPI-4835

1| Connect to the positive terminal of the battery

---|---
2| Connect to the negative terminal of the battery

3| Connect to the Battery Temp Sense (BTS)

4| Interlock Connection – the interlock cable connections provide a normally open or normally closed circuit with no voltage, which changes state when the charger is operational.
| 4a| Normally open
4b| Normally closed
4c| Common
5| USB Terminal for Charge Profile settings

WARNING

  • Please make sure the battery connection cables are correctly connected to the charger terminals before operating the charger

Image refers to EPI-4860

1 AC Input
2 DC Battery Connection

Black = Negative

White = Temp. Sens

3| Brake Switch| When AC has power – open the circuit

When AC has NO power – closed circuit

4| Charger Switch| Open circuit – charger ON

Closed-circuit – charger OFF

5| Remote LED|

MAINTENANCE INSTRUCTIONS

  1. Do not expose the charger to oil, dirt, mud, or direct heavy water spray when cleaning the vehicle.
  2. The enclosure of the charger has been tested successfully to EN60529, meeting IP66 compliance.
  3. If the detachable AC input power supply cable is damaged, replace it with a cable that is a detachable cable, 3 conductors, 1.5 mm² minimum, and rated appropriate for use in the country of destination. AC input type to the charger is type IEC 60320 C14 plug. safety approved

FAULT INDICATION WITH LED DISPLAY

When a fault occurs, LED2(100%)/LED3(75%)/LED4(50%)will blink at the same time.

Blinking

Frequency

(every 4 sec)

| Fault Cause| Solution
---|---|---
1.| The battery is not connected or the battery

voltage is too low

| 1) Check battery connection is correct.

  1. Check charger connection is correct.

  2. Check each battery is good.

2.| Abnormal AC Power Input (Voltage)| 1)  Check AC input cord is connected between

the charger and the AC outlet.

2)  Make sure the AC plug is tightly inserted into the AC outlet.

3.| Charger High-Temperature Protection| 1)  Charger shuts down and enters protection mode due

to charger/environmental temperature being too high. Please

place the charger in a well-ventilated environment.

2)  Disconnect the charger and wait for 15-20 mins before

reconnecting for charging.

4.| Battery High-Temperature Protection| 1)Charger will reduce output current and stop charging

when the battery temperature exceeds 50°.

2)When the battery temperature drops, the charger will

reset automatically.

5.| Output Current is too large| Return to the factory for repair.
6.| Battery Voltage is too high| Check and assure that the correct output battery voltage

is connected.

| |

WITH DIGITAL DISPLAY

Blinking

Frequency

| Fault Cause| Solution
---|---|---
E01    bAt| The battery is not connected or the battery

is in reverse or the battery is damaged

| 1) Check battery connection is correct.

  1. Check charger connection is correct.

  2. Check each battery is good.

E02    AC| Abnormal AC Power Input (Voltage)| 1) Check AC input cord is connected between the charger and the AC outlet.

  1. Make sure AC plug is tightly inserted into AC outlet

E03    Hot| Charger High-Temperature Protection| 1) Charger shuts down and enters protection mode due to charger/environmental temperature being too high. Please place the charger in a well-ventilated environment.

  1. Disconnect the charger and wait for 15-20 mins before reconnecting for charging.

E04    bAt| Battery High-Temperature Protection| 1) Charger will reduce output current and stop charging when the battery temperature exceeds 50°.

  1. When the battery temperature drops, the charger will reset automatically.

E05    Err| Internal error in product| Return to the factory for repair.
E06    bAt| Battery Voltage is too high| Check and assure that the correct output battery voltage is connected.

WATERPROOFING INSTALLATION

Waterproof ring installation of the AC input cable.

  1. Slip waterproof ring or grommet over the AC input cable
  2. Connect the AC input cable into the charger ensuring the waterproofing ring is seated correctly
  3. Firmly tighten the waterproofing clamp using a Phillips head screwdriver

* _NOTE:_** Take care to not overtighten the waterproof clamp.

Enerdrive ePOWER Industrial Battery Charger-
INSTALLATION

SPECIFICATIONS

Model: EPI-2430 EPI-3620 EPI-4815 EPI-4835 EPI-4860
DC Output
Voltage-nom (V) 24V 36V 48V 48V 48V
Voltage-max (V) 34V 51V 68V 68V 68V
Current-max (A) 30A 20A 15A 35A 60A
Applicable to Battery AGM, Flooded, GEL, Lithium
Reverse Polarity Electronic Protection – auto – reset
Short Circuit Electronic Protection – auto – reset
AC Input 100 – 240V 100 – 240V

Voltage Range (V)
Frequency (Hz)| 45 – 65Hz| 45 – 65Hz
Power max (W)| 850W| 1985W| 3400W
| | |
Dimensions| 20.7 x 18.0 x 16.0 cm| 19.5 x 18.0 x 19.5 cm| 35.9 x 28.0 x 10.7 cm
Weight| 4.6 kg| 5.2 kg| 10 kg
Operating Temperature| -20C∼ +50C| -20C ∼+50C| -20C ∼ +50C
Storage Temperature| -40C ∼ +70C| -40C ∼+70C| -40C ∼ +70C

  • IP Rating: IP66 when AC input waterproof ring/grommet is used. See Page 12.

Note: Specifications are subject to change without notices.

CHARGE PROFILE

Charge Profile Instructions:

Changing the Charge Profile on the Enerdrive ePOWER Industrial Charger

The ePOWER Industrial charger has the ability to be programmed with a charge profile (algorithm) to suit any battery. The default charge profile that comes installed on the charger is b02. This charging profile is suited for Trojan T105 batteries. You can change the charge profile installed on the charger at any time via the USB port on the front of the charger.

NOTE: You will require a formatted (FAT32) USB memory stick with a capacity of 1024KB or larger.

Please carefully follow the steps below to change the charge profile: –

  1. Download and save the Battery Algorithm Listing from the download link www.enerdrive.com.au/Algorithm/ePOWER-algorithm.xlsx
  2. Select a charge profile that matches the batteries you are using from the “Charge Profile Listing” tab in this spreadsheet.
  3. Right-click on the selected Charge Profile in the “Charge Profile column and click “Copy”.
  4. Now “Paste the copied charge profile to your formatted USB memory
  5. Make sure the charger is NOT connected to the battery or AC power.
  6. Unscrew the round cap covering the USB port on the front of the charger and insert the USB memory
  7. Plug the AC power cord into the charger and switch ON AC
  8. Please allow up to 1 min for Programming to be complete once the USB status LED is “SOLID”.
  9. Switch OFF AC power to the \
  10. Remove USB memory stick and screw USB cap back on.
  11. Switch ON AC power to the charger and check the charge profile you selected has been installed. The charger will display the installed charge profile as a series of flashes of the Battery Capacity LED. See the user manual for the explanation.
  12. Switch OFF AC power to the charger.
  13. Connect the charger to the DC battery.
  14. Switch ON the AC power to the charger to begin charging with the installed charge profile.

The ePOWER Industrial charger can also be programmed with a custom (user- defined) charge profile for batteries that are not listed. If you cannot find a suitable charge profile for your batteries please contact Enerdrive.

PLEASE NOTE: AU relevant battery charging specifications MUST be supplied in order for us to be able to create a custom charge profile for you. See the following page for the Charge Profile Table.

Charge Profile Table:

Algorithm No.| Manufacturer| Model| Batt Type| Ah_C20|
---|---|---|---|---|---
b38| Custom Setup| Custom Setup| Custom| Custom|
b01| Common| Common type of flooded| Flooded| 300|
b02| Trojan| TROJAN T105| Flooded| 225|
b04| Discover| Discover AGM| AGM| 250|
b05| US| US battery Flooded| Flooded| 250|
b06| Trojan| Trojan 30XH5| Flooded| 130|
b07| Trojan| Trojan T125| Flooded| 240|
330
260|
b08| Trojan Trojan 1305| Flooded|
b10| Trojan Trojan T145 Flooded|
b11| Trojan Trojan T1275 Flooded| 150|
b12| Discover DGC6A-220D AGM                        AGM| 220|
210|
b13| Trojan Trojan T605 Flooded|
b18| Trojan Trojan T875 Flooded Flooded| 170
216
232|
b19| US US2000 Flooded                                Flooded|
b20| US US2200 Flooded                                Flooded|
b25| Fullriver| Full river DC224-6 AGM| Flooded| 224|
b27| Trojan| Trojan 116P-AC Flooded| Flooded| 420|
b28| Common| Generic 200-370Ah AGM| AGM| 300|
b29| US| US.8VGCXC2 Flooded| Flooded| 170|
b30| US| US. 12VXC2 Flooded| Flooded| 155|
b31| US| US 305XC Flooded| Flooded| 310|
b32| US| US 125 XC2 FLA| Flooded| 242|
b33| US| US 145 XC2 FLA| Flooded| 251|
b34| Crown| Crown CR-235 FLA| Flooded| 235|
b35| Crown| Crown CR-245 FLA| Flooded| 245|

WARRANTY

5 Year Warranty

In the unlikely event that a technical issue arises with an Enerdrive product, customers are encouraged to initially contact the Enerdrive Support Team on 1300 851 535 or support@enerdrive.com.au for immediate and efficient expertise and first-class product support.

Important Note: Consumer Protections
If you have purchased your product in Australia, you should be aware that:
This warranty is provided in addition to other rights and remedies held by a consumer at law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Enerdrive warrants that its Products will be free from defects in materials and workmanship (subject to limits, and in normal conditions, as described in the complete Enerdrive Warranty Policy) for up to 5 years from the date of purchase. For full terms, conditions, and claim process, refer to the Enerdrive website. https://enerdrive.com.au/warranty/

ENERDRIVE PTY LTD
P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178
Ph: 1300 851 535 / Fax: 07 3390 6911
Email: support@enerdrive.com.au
Web: www.enerdrive.com.au

Enerdrive ePOWER Industrial Battery Charger Owner’s Manual (Rev. 1.6)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Enerdrive User Manuals