Enerdrive B-TEC 200Ah Slim Metal Case Lithium Battery Owner’s Manual

June 9, 2024
Enerdrive

Enerdrive B-TEC 200Ah Slim Metal Case Lithium Battery Owner’s Manual
Enerdrive B-TEC 200Ah Slim Metal Case Lithium
Battery

Installation

Your B-TEC battery must be installed in a dry and cool location. Supplied battery trays and straps are the preferred mounting method. Ensure that suciently rated fasteners are used to hold the tray rmly to the mounting material. Enerdrive highly recommend the battery is installed in the upright position. Enerdrive approve installation of B-TEC batteries in accommodation areas of RV’s. Temperatures must not exceed the rated operating temperatures therefore natural, or fan forced ventilation maybe required. There should be 25mm clear space around the B-TEC battery. Consideration should be taken to not mount the battery near any metallic service lines such as LPG, diesel, or petrol lines. This is to ensure no accidental shorting of the battery terminals occur, especially when tting or removing the battery. B-TEC batteries must not be installed –

  • In vehicle engine bays or in high heat environments, refer to Section 10 – Battery Specications
  • In wet areas such as caravan chassis mounts, open ute trays or boat deck areas.
  • Inside compartments dedicated to carrying gas.

Connection

It is recommended that no more than four terminals be connected to a battery terminal, if you do have more than 4 terminals the use of a fuse block and negative busbar are recommended. Cable terminal should be in the order with heaviest current draw (largest cable) in contact with the battery to light est. current draw (smallest cable) terminals on the top. Use of insulating terminal boots is recommended, especially in areas where accidental shorting may occur, such as storage lockers or under lounges and beds. Connect the Positive (Red) and Negative (Black) cables to the battery, ensuring you are using cable that is of adequate size for the demands of the system, and well crimped and protected termination lugs.

Example;
1000W Inverter – at least Guage 2 (35mm²)
2000W Inverter – at least Guage 00 (70mm²
3000W Inverter – at least Guage 000 (95mm²)

Cable Conversion Guide

The spring washers must be used on the battery terminal bolts – they apply pressure to the lugs for a secure connection. There is no need to over-tighten the bolts, simply ensure there is no movement of the cables. Make sure the main Battery Cable lug is mounted directly onto the Battery terminal with no washers between them.

Charging

Lithium batteries need to be charged slightly dierent to other batteries. To ensure they live a long life and provide maximum capacity, you must use a charger with a lithium LiFeP04 setting – this includes:

  • AC Chargers
  • DC to DC Chargers
  • Solar Controllers

If your charger allows, set the charge voltage from 14.2 – 14.6 Volts and Float 13.5 – 13.6 Volts and proceed with charging. We recommend charging at the lower end of the voltage scale for maximum longevity of the battery. It is recommended that the charging current should be 30% of your battery capacity. You can charge at higher currents but 30% is the recommended for long life. See Section 10 – Battery Specications.
*Note: You can charge a lithium battery with a non-lithium charger, but these chargers can deliver too much or too little voltage and may not cut o when the battery is full. DO NOT use a charger with a “Pulse Stage” or “Equalisation Mode”. This will damage the battery and void warranty. DO NOT connect this battery to a start battery with a VSR (Dual Battery System or “Voltage Sensitive Relay”). The voltage of the Lithium battery may keep the VSR switched on resulting in it discharging into the start battery, and/or attening the start battery. DO NOT charge B-TEC batteries direct from an alternator.

Discharging (using the battery)

The Enerdrive B-TEC Lithium Battery can deliver a very high discharge current due to the high power, high quality Battery Management System (BMS) and prismatic Lithium cells inside the battery. Refer to Section 10 – Battery Specications for the maximum rated discharge current of your battery. For this to happen, you MUST USE cable of the correct guage.

Inverter Usage
It is recommended to not put more load on your batteries than the rating of the BMS installed. We also recommend following the below even if you have two batteries in parallel, this protects overloading a single battery if the other battery in the bank was to shut down (i.e. low capacity).

  • 12V 100AH B-TEC – 12V 1000W Inverter Max
  • 12V 125AH B-TEC – 12V 1000W Inverter Max
  • 12V 200AH B-TEC – 12V 2600W Inverter Max
  • 12V 300AH B-TEC – 12V 3000W Inverter Max
  • 24V 150AH B-TEC – 24V 3500W Inverter Max

Protecting Your Battery

Lithium batteries cannot be protected eectively by monitoring voltage due to their ability to maintain ahigher voltage for much longer than AGM or ooded/sealed batteries. “State of Charge” (SOC%) percentage is the most accurate and eective method of disconnecting loads from the battery – this requires a battery monitor which uses a “shunt” to measure the current going into (Charging) and coming out of (Discharging) the battery

Example;
200 Amp Battery Fully Charged State of Charge = 100%
50 Amps used State of Charge = 75%
100 Amps used State of Charge = 50%
It is recommended that Lithium batteries not be discharged below 20% State of Charge or the battery life may be shortened.
As an added layer of protection, the Enerdrive B-TEC Lithium Battery also has a built-in low voltage disconnect circuit. If this occurs, please refer to Section 6 – Restarting Your Battery.
If your battery has shut down due to low voltage you must charge your battery within 14 days to prevent permanent damage occuring to the cells.

Restarting Your Battery

Batteries with Reset Button on Battery

We strongly recommend keeping the battery charged to avoid activating the internal low battery voltage discconnect. If your DC system shuts down, the battery may require re-starting. Please use the following procedure:

  1. Turn o all DC and AC Loads
  2. Connect charging source/s and switch ON
  3. Hold the “Reset” button 5 seconds, release and quick press
  4. Release and wait 7 seconds
  5. Power will be restored and charging will commence after a few seconds
  6. When the SOC (State of Charge) is above 20%, loads can be switched on if required

Overview

By continuously tripping the low voltage discconnect of the battery you may cause damage to sensitive electronic equipment that is attached to the battery. i.e. battery chargers, solar controllers, inverters, stereo equipment etc – all of which are not covered under the battery warranty

Batteries without Reset Button on Battery

To reconnect, a charge voltage of ≥12.8v must be applied to the battery before the over-discharge release will activate and allow charge current to ow into the battery. This can be done via a momentary reset switch between the start battery and B-TEC or by jump starting with a portable power pack. Follow the above steps to turn o all DC and AC loads, turn on charging sources and then activate reset switch or apply jump start pack, disconnect as soon as chargers begin charging.

Using the Smart Phone Battery Monitor App

The Enerdrive B-TEC Lithium Battery incorporates a wireless Smart Phone Monitoring system. By downloading the Android™ or Apple® app to your Smart Phone or tablet device, you can monitor the following information;

  • Battery Capacity
  • Individual Cell Voltage
  • Battery Voltage
  • Battery Temperature
  • Battery Current (Amps)
  • Battery Cycles
  • Battery State of Charge (SOC)
  • Battery Alarms
  • Battery State of Health (SOH)
  • Battery Notications
  • Battery Status

Monitor App

Alarms Denitions

HV – High Voltage
LV – Low Voltage
OCC – Over Current Charge
OCD – Over Current Discharge
LTD – Low Temperature Discharge
LTC – Low Temperature Charge
HTD – High Temperature Discharge
HTC – High Temperature Charge
(Refer to Section 10 – Battery Specications for values).

  • The red warning light is only an indicator, not a fault condition.
  • The 3 vertical dots on the lower part of the main screen allows you to change the Bluetooth name of the battery. Touch the dots, and use 1234 as the password to enter your battery name.
  • A notication will only appear in the notications page if under alarm condition.

Warnings

Please read and follow the cautions listed on the battery before installation. Improper use may cause heat, re, rupture, damage or capacity deterioration of the battery. Dometic Power & Control (Enerdrive) Pty Ltd is not responsible for any accidents cause by the usage without following our specication.

Warning

Failure to follow these instructions may result in early battery failure or possible personal injury.

  • Do not use the battery for cranking/starting applications.
  • Do not series connect the battery.
  • Do not dispose of in fire.
  • The battery must be installed far away from heat sources, high voltage, and avoid exposed sunlight for long periods of time.
  • Do not throw the battery into water.
  • Do not connect the positive and negative terminals of battery together.
  • Do not ship or store battery together with metal.
  • Do not disassemble the battery. Battery warranty will be voided if the case is opened.
  • Do not drop, impact or puncture the battery.
  • Do not allow the battery to sit in a discharged state511.50V
  • When the battery capacity is low (515% SOC), please charge the battery.
  • Please use the matched or suggested charger that contains a Lithium charge profile for this battery. Failure to install the correct battery charger will void all warranty.
  • If the battery emits a peculiar smell, heating, distortion or appears to have any abnormality during operation or storage, please stop using the battery and take it out of service. Contact Enerdrive for further details
  • If the battery leaks and gets into eyes or on skin, do not wipe. Rinse with clean water and seek medical attention immediately.

Low battery voltage desconnect

The battery has a low voltage disconnect incorporated for self-protection. If the battery is drawn down to the internal low voltage disconnect set point 2.8v per cell (11.2V for 12V battery) the battery will disconnect.

FAQ

Q: Can I parallel B-TEC batteries?
A: The short answer is yes. The long answer is – if you are drawing large currents, the maximum current delivered will be limited to the maximum instantaneous discharge capacity of one battery, for example; 200A on a 200Ah G2 B-TEC Battery. With low to medium current draw installations (the vast majority of applications) you may never see an issue and your storage capacity will be greatly increased – I.E. 2 x 200 Amp = 400 Amp capacity. When installing, fully charge the batteries separately – then let sit for 30 minutes before connecting together. When connecting in parallel – take the positive from Battery 1, and the negative from Battery 2 to your system as per the diagram below.

Product Instruction

The Smart Phone App will only show the information from one battery at a time – not both. This is another advantage of a separate Battery Monitor – it will show the total system environment.
Note: Slight variance of State of Charge or Amps may occur between the batteries in parallel however these should not vary by more than 5%. It is recommend that annually the batteries be disconnected and individually charged allowing them to sit at a fully charged state for 12hrs each before connecting back together.

Q: Can I series connect B-TEC batteries to achieve higher voltage?
A: No. Enerdrive oers higher voltage Lithium solutions – contact us for details.
Q: Can I use an Inverter with my B-TEC battery?
A: Yes. Refer to Section 4 for more detail.
Q: Can I install the B-TEC battery in a wet area?
A: No. Due to the construction of the B-TEC cases the batteries must be installed in a dry environment to protect against moisture ingress.
Q: Can I install the B-TEC battery on its side or end?
A: No.

Specications

SPECIFICATIONS: Enerdrive B-TEC 12v-G2 Lithium Battery Technical Data – 12 VOLT

**| EPL-100BT-12V-SLIM| EPL-125BT-12V-G2| EPL-200BT-12V-G2| EPL-300BT-12V-G2
Nominal Voltage| 12.8V
Nominal Capacity| 100Ah| 125Ah| 200Ah| 300Ah
Cycle Life (DOD – 80%under controlled conditions)| ≥2000 Cycles
Standard Charge Specification (Lithium profile charger required)*
Battery Charge Temperature| 0 – 45˚C
Normal Charge Voltage CV/CC
| 14.20 ~14.60
Standby (Float) Voltage| 13.50 ~13.80
Maximum Charge Current| 80A @ 25˚C for 30mins| 80A @ 25˚C for 30mins| 150A @ 25˚C for 30mins| 190A @ 25˚C for 30mins
Nominal Charge Current for Maximum Life| 20~50A| 20~60A| 40~100A| 80~120A
Standard Discharge Specification
Battery Discharge Temperature| -20˚C ~ 60˚C
Battery Output Voltage Range| 11.0 ~ 14.60V approx.
Maximum Discharge Current| 100A @ 25˚C ±5˚C for 30 mins| 100A @ 25˚C ±5˚C for 30 mins| 200A @ 25˚C ±5˚C for 30 mins| 250A @ 25˚C ±5˚C for 15 mins
Pulse Discharge Current| 250A for 1.0s| 450A for 1.0s
Discharge Cut-Off Voltage| ≤11.20V
Circuit Protection
The battery is supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimise each single prismatic cell during charge & discharge, to protect the battery pack from overcharge, over discharge & short circuit. Overall, the BMS helps to ensure safe and accurate operation of the battery.
Over-Charge Protection
Over-Charge Protection Per Cell| 3.90 ± 0.03V
Over-Charge Release Per Cell| 3.60 ± 0.05V
Over-Charge Release Method| Discharge below release voltage
Over-Discharge Protection
Over-Discharge Protection Per Cell| 2.80V ± 0.05V
Over-Discharge Release Per Cell| 3.20V ± 0.05V
Over-Disharge Release Method| Apply Charge/Voltage ≥12.8v
Over Current Protection
Discharge Over Current| 110A for 30s – 450A for 1s| 110A for 30s – 450A for 1s| 220A for 30s – 450A for 1s| 280A for 25s – 400A for 3.5s
Protection Reset Time| Approx 10s Auto Release
Over Current Release Method| Disconnect Load
Over Temperature Protection
Battery Discharge Over Temp| Protection to 65˚C ± 5˚C
Protection to 50˚C ± 5˚C
Battery Charge Over Temp| Protection to 55˚C ± 5˚C
Protection to 45˚C ± 5˚C
Short Circuit Protection| Auto release after 5s
Mechanical Characteristics| Without Tray| Without Tray| With Tray| Without Tray| With Tray| Without Tray| With Tray
**** Dimensions| Length| 551mm| 318mm| 318mm| 505mm| 505mm| 521mm| 521mm
Width| 110mm| 165mm| 165mm| 173mm| 173mm| 280mm| 288mm
Height| 240mm| 232mm| 240mm| 265mm| 272mm| 253mm| 261mm
Weight               Approx. 12.5kg| Approx. 15.5kg| Approx. 16.2kg| Approx. 25.0kg| Approx. 26.0kg| Approx. 38.2kg| Approx. 39.4kg
Storage Information
** Temperature & Humidity Range| ≤30 days – 20˚C to 60˚C, 5 ~ 75% RH
≥90 days – 10˚C to 45˚C, 5 ~ to 75% RH
Self-Discharge Rate| ≤3% per month
SPECIFICATIONS: Enerdrive B-TEC Lithium Battery Technical Data – 24 & 36 VOLT**

**| EPL-100BT-24V| EPL-150BT-24V-G2| EPL-100BT-36V
Nominal Voltage| 25.6V| 25.6V| 38.4V
Nominal Capacity| 100Ah| 150Ah| 100Ah
Cycle Life (DOD – 80%under controlled conditions)| **
≥2000 Cycles
Standard Charge Specification (Lithium profile charger required)
Battery Charge Temperature| 0 – 45˚C
Normal Charge Voltage CV/CC*| 28.80 ~29.20| 28.80 ~29.20| 43.20 ~43.80V
Standby (Float) Voltage| 27.00 ~27.60| 27.00 ~27.60| 40.5 ~41.40V
Maximum Charge Current| 50A @ 25˚C for 30mins| 100A @ 25˚C for 60mins| 50A @ 25˚C for 30mins
Recommended Charge Current for Maximum Life| 20~50A| 30~75A| 20~50A
Standard Discharge Specification
Battery Discharge Temperature| -20˚C ~ 60˚C
Battery Output Voltage Range| 22.0 ~ 29.20V| 22.0 ~ 29.20V| 33.0 ~ 43.80V
Maximum Discharge Current| 100A @ 25˚C ±5˚C for 30 mins| 150A @ 25˚C ±5˚C for 30 mins| 100A @ 25˚C ±5˚C for 30 mins
Pulse Discharge Current| 450A for 1.0s
Discharge Cut-Off Voltage| ≤22.40V| ≤22.40V| ≤33.60V
Circuit Protection
The battery is supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimise each single prismatic cell during charge & discharge, to protect the battery pack from overcharge, over discharge & short circuit. Overall, the BMS helps to ensure safe and accurate operation of the battery.
Over-Charge Protection
Over-Charge Protection Per Cell| 3.90 ± 0.03V
Over-Charge Release Per Cell| 3.60 ± 0.05V
Over-Charge Release Method| Discharge below release voltage
Over-Discharge Protection
Over-Discharge Protection Per Cell| 2.80V ± 0.05V
Over-Discharge Release Per Cell| 3.20V ± 0.05V
Over-Disharge Release Method| Apply Charge/Voltage ≥25.6v| Apply Charge/Voltage ≥25.6v| Apply Charge/Voltage ≥38.4v
Over Current Protection
Discharge Over Current| 110A for 30s – 450A for 1s| 170A for 10s – 400A for 3.5s| 110A for 30s – 450A for 1s
Protection Reset Time| Approx. 30s Auto Release
Over Current Release Method| Disconnect Load
Over Temperature Protection
Battery Discharge Over Temp| Protection to 65˚C ± 5˚C
Protection to 50˚C ± 5˚C
Battery Charge Over Temp| Protection to 55˚C ± 5˚C
Protection to 45˚C ± 5˚C
Short Circuit Protection| Auto release after 5s
Mechanical Characteristics| Without Tray| Without Tray| With Tray| Without Tray
** Dimensions| Length| 446mm| 521mm| 521mm| 520mm
Width| 161mm| 280mm| 288mm| 273mm
Height| 245mm| 253mm| 261mm| 225mm
Weight| Weight| Approx. 25.0kg| Approx. 38.2kg| Approx. 39.4kg| Approx. 37.7kg
Storage Information
**
Temperature & Humidity Range| ≤30 days – 20˚C to 60˚C, 5 ~ 75% RH
≥90 days – 10˚C to 45˚C, 5 ~ to 75% RH
Self-Discharge Rate| ≤3% per month

DIMENSIONS (NO STRAP & TRAY INCLUDED WITH THIS MODEL)

DIMENSIONS

DIMENSIONS WITHOUT STRAP & TRAY

DIMENSIONS

DIMENSIONS WITH STRAP & TRAY 232

DIMENSIONS

DIMENSIONS WITHOUT STRAP & TRAY

DIMENSIONS

DIMENSIONS WITH STRAP & TRAY

DIMENSIONS

DIMENSIONS WITHOUT STRAP & TRAY

DIMENSIONS

DIMENSIONS WITH STRAP & TRAY

DIMENSIONS

EPL-100BT-24V

DIMENSIONS

DIMENSIONS WITHOUT STRAP & TRAY

DIMENSIONS

DIMENSIONS

Warranty

5 Year Warranty

In the unlikely event that a technical issue arises with an Dometic Power & Control (Enerdrive) Pty Ltd product, customers are encouraged to initially contact the Enerdrive Support Team on 1300 851 535 or support@enerdrive.com.au for immediate and ecient expertise and rst class product support.

Important Note: Consumer Protections

If you have purchased your product in Australia, you should be aware that: This warranty is provided in addition to other rights and remedies held by a consumer at law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Dometic Power & Control (Enerdrive) Pty Ltd warrants that its Products will be free from defects in materials and workmanship (subject to limits, and in normal conditions, as described in the complete Enerdrive Warranty Policy) for up to 5 years from the date of purchase. For full terms, conditions and claim process, refer to the Enerdrive website.
https://enerdrive.com.au/warranty/

Dometic Power & Control (Enerdrive) Pty Ltd
P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178
Ph: 1300 851 535 / Fax: 07 3390 6911
Email: support@enerdrive.com.au
Web: www.enerdrive.com.au

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Enerdrive User Manuals

Related Manuals