Enerdrive ePOWER Industrial Multi Stage Battery Charger Owner’s Manual
- June 3, 2024
- Enerdrive
Table of Contents
- Enerdrive ePOWER Industrial Multi Stage Battery Charger
- INTRODUCTION
- IMPORTANT SAFETY INFORMATION
- LIMITATIONS OF USE
- PRODUCT DESCRIPTION
- INSTALLATION
- OPERATION ILLUSTRATION LED
- Connecting the Cables
- MAINTENANCE INSTRUCTIONS
- FAULT INDICATION
- WATERPROOFING INSTALLATION
- SPECIFICATIONS
- CHARGE PROFILE
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Enerdrive ePOWER Industrial Multi Stage Battery Charger
PLEASE KEEP THIS MANUAL FOR FUTURE
REFERENCE
For safe and optimum performance, the Enerdrive ePOWER Industrial Battery
Charger must be used properly. Carefully read and follow all instructions and
guidelines in this manual and give special attention to the CAUTION and
WARNING statements.
Disclaimer
While every precaution has been taken to ensure the accuracy of the contents
of this guide, Enerdrive assumes no
Important
Please be sure to read and save the entire manual before using your Enerdrive
ePOWER Industrial Battery Charger. Misuse may result in damage to the unit
batteries and/or cause harm or serious injury. Read manual in its entirety
before using the unit and save manual for future reference.
Product Numbers – ePOWER Industrial Battery Charger Series
EPI-2430 | ePOWER Industrial Battery Charger 24V / 30Amp |
---|---|
EPI-3620 | ePOWER Industrial Battery Charger 36V / 20Amp |
EPI-4815 | ePOWER Industrial Battery Charger 48V / 15Amp |
EPI-4835 | ePOWER Industrial Battery Charger 48V / 35Amp |
EPI-4860 | ePOWER Industrial Battery Charger 48V / 60Amp |
ePOWER Industrial Battery Charger Owner’s Manual 1.8. This manual applicable to all units with serial number prefix EPI.
Service Contact Information
Dometic Power & Control (Enerdrive) Pty Ltd
P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178
Ph: 1300 851 535 / Fax: 07 3390 6911
Email: sales@enerdrive.com.au | Web:
www.enerdrive.com.au
NOTICE OF COPYRIGHT
Enerdrive ePOWER Industrial Battery Charger owner’s manual © 2021 Dometic
Power & Control (Enerdrive) Pty Ltd. All rights reserved. No part of this
document may be reproduced in any form or disclosed to third parties without
the express written permission of Dometic Power & Control (Enerdrive) Pty Ltd,
P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178. Enerdrive reserves
the right to revise this document and to periodically make changes to the
content hereof without obligationor organization of such revisions or
changes,unless required to do so by prior arrangement. Exclusions For
Documentation And Product Usage any technical or other information provided in
its manuals or other documentation Assumes no responsibility or liability for
losses, damages, costs or expenses, whether special, direct, indirect,
consequential or incidental, which might arise out of the use of such
information. The use of any such information will be entirely at the user’s
risk Reminds you that if this manual is in any language other than English
although steps have been taken to maintain the accuracy of the translation,
the accuracy cannot be guaranteed Makes no warranty, either expressed or
implied, including but not limited to any implied warranties of
merchantability or an “as is” basis Shall in no event be liable to anyone for
special, collateral, incidental, or consequential damages in connection with
or arising out of purchase or use of these Enerdrive products. The sole and
exclusive liability to Enerdrive, regardless of the form of action, shall not
exceed the purchase price of the Enerdrive products described here in
INTRODUCTION
Thank you for purchasing the Enerdrive ePOWER Industrial Battery Charger. With our state Please read and follow these instructions and precautions carefully.
IMPORTANT SAFETY INFORMATION
This section contains important safety information for the Enerdrive ePOWER Industrial Battery Charger. Each time, before using the Enerdrive ePOWER Industrial Battery Charger, READ ALL instructions and cautionary markings on or provided with the battery charger, and all appropriate sections of this guide. The Enerdrive ePOWER Industrial Battery Charger contains no user serviceable parts. Opening up the charger will void product warranty. See Warranty section for how to handle product issues.
WARNING
FIRE AND/OR CHEMICAL BURN HAZARD
- Do not cover or obstruct any cooling fins and/or install in a zero-clearance compartment.
WARNING
SHOCK HAZARD. KEEP AWAY FROM CHILDREN!
- Avoid moisture ingress. Never expose the unit to snow, water, etc.
WARNING: EXPLOSION HAZARD!
- .DO NOT use the Enerdrive ePOWER Industrial Battery Charger in the vicinity of flammable fumes or gases (such as gas bottles or large engines).
- AVOID covering the cooling fins. Always operate unit in an open and well ventilated area.
- Prolonged contact to high heat or freezing temperatures will decrease the working life of the unit.
WARNING
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR SERIOUS INJURY
- When working with electrical equipment or lead acid batteries, have someone nearby in case of an emergency.
- Study and follow allthe battery manufacturer’s specific precautions when installing, using and servicing the battery connected to the charger.
- Wear eye protection and gloves
- Avoid touching your eyes while using this unit.
- Keep fresh water and soap on hand in the event battery acid comes in contact with eyes.
- If this occurs, cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention.
- Batteries produce explosive gases.
- DO NOT smoke or have an open spark or fire near the system.
- Never attempt to re-charge a damaged, frozen or non-rechargeable battery.
- Keep unit away from moist or damp areas.
- Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short circuit which goes through the battery or another electrical tool that may create an explosion.
- Battery charger must be plugged in to an earthed and Australian Standards compliant mains supply. If the units power cable is damaged, replace the cable immediately.
LIMITATIONS OF USE
- Do not use in connection with life support systems or other medical equipment or devices.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision and instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
WARNING
- Enerdrive recommends that all wiring be done by a skilled technician to ensure adherence to the best practice standards for on-board DC electrical installations. Failure to follow these instructions can damage the unit and could also result in personal injury or loss of life.
CAUTION
- Before Beginning Your Unit Installation, Please Consider The Following:
- The unit should be used or stored in an indoor area away from direct sunlight, heat, moisture or conductive contaminants. Do not install the ePOWER Industrial Battery Charger in corrosive environments.
- When placing the unit, allow a minimum of 75mm of space around the unit for optimal ventilation.
PRODUCT DESCRIPTION
The Enerdrive ePOWER Industrial Battery Charger package includes the items listed below.
- ePOWER Industrial Battery Charger
- IEC 240Vac Power Lead
- Waterproofing grommet for Power Lead
- Owner’s manual
INSTALLATION
- This charger is to be installed in a cool and well ventilated location.
- Although certain models are waterproof, it is recommended to install in a dry location.
- When using in a fixed installation use suitable fasteners (screws or bolts) to secure the charger to a solid surface that can handle the weight and forces when the vehicle is moving.
OPERATION ILLUSTRATION LED
Indicators and Fault Signals:
LED Indicators during start up:
- In order to find out the installed charging profile in the unit, please follow the steps below. 1. Make sure the DC cables are not connected to the battery.
- Connect the AC input to the charger and switch on.
- The charger LED display panel will indicate the battery charge algorithm profile installed.
LED Indicators and Digital Display:
Charger will enter charging model when connecting to battery & AC input cable. Digital display on the front panel will show in turn: AC XXX (Current AC input voltage), CPU X.XX (corresponding software version number), b**(Current charging profile code). To change the charging profile, press & hold the Select button for 5 seconds, then press the Select button to choose the desired profile. Once selected, press & hold the Select key for 5 seconds, and the charging profile selection will be completed. To start EQ mode, press & hold the Select button for 10 seconds, and display will show EQ mode. The next charging cycle will go into EQ mode. If you want to quit the EQ mode, hold the Select button for 10 seconds. When display shows OFF, the charger will quit the EQ mode.
Common Mode (Default) & BMS Mode:
- A: The charger enters BMS mode when being connected to lithium-ion battery through Can Bus;
- B: . For safety reason, the charger will flash “bnS” if being reconnected to Lead-acid battery under a BMS mode;
- C: Insert the AC power into the charger,the charger will only charge Lead-acid type battery again if you refresh the charger through USBport with the desired lead acid battery charging profile via USB drive.
Charging Status Indicator and Status Display
- % Capacity Percentage Indicator: Display shows charging percentage. e.g. 10 20 30…100 (%)
- V Charging Voltage Indicator: Display shows charging voltage. e.g. 24.0 (V)
- A Charging Current Indicator: Display shows charging voltage. e.g. 36.0 (V)
Additional Battery Voltmeter Function (Optional functions)
- B Battery Voltage Indicator. To check battery voltage, disconnect charger AC input and press “Select” button for 1 second. Display shows battery voltage. e.g. 24.0 (V).
Battery Capacity Indicators:
LED will be showing Battery Charging Profile as below:
LED 1 | LED 2 (100% Indicator) | LED 3 (75% Indicator) | LED 4 (50% Indicator) |
---|---|---|---|
Algorithm 30+ | Algorithm 20+ | Algorithm 10+ | Algorithm 1 – 9 |
For example;
- If the charging profle has been selected to #35, LED 1 will be on to represent the charging profle is 30, and LED 4 will link 5 times to indicate algoríthım #35, while LED 2 and LED 3 will remain off.
- If the charging profle has been selected to #18, LED 3 will be on to represent the charging profle is 10, and LED 4 will link 8 times to indicate algorithm #18, while LED 1 and LED 2 will remain of.
Connecting the Cables
- 1. Connect to the positive terminal of the battery
- 2. Connect to the negative terminal of the battery/ BTIS-
- 3. Connect to the BTS+
- 4,5,6: Interlock Cable (4,6: NO the interlock cables will form an open circuit with no voltage. 5,6: NC The interlock cable will form a short circuit with no voltage).
- 7. Connect CANBUS or LED light wire (optional function).
Warning: Assure the battery connection cable is well connected with the charger before it is connected to the battery. Otherwise, the battery short circuit may occur and cause personal injury or damage to the battery.
WARNING
- Please make sure the battery connection cables are correctly connected to the charger terminals before operating the charger
- Always connect the positive cable to the battery first, then the negative cable to the negative (chassis for B negative grounded vehicles) prior to connecting to supply mains.
- After charging, and when removing charger,always disconnect the battery charger from the supply mains, then disconnect the negative/chais connection and then the positive connection.
- Supply mains wiring in fixed installs such as caravans or similar vehidles must be in accordance with the national Wiring rules
WARNING
- Please make sure the battery connection cables are correctly connected to the charger terminals before operating the charger
- Always connect the positive cable to the battery first, then the negative cable to the negative (chassis for negative grounded vehicles) prior to connecting to supply mains.
- After charging, and when removing charger, always disconnect the battery charger from the supply mains, then disconnect the negative/chassis connection and then the positive connection.
- Supply mains wiring in fixed installs such as caravans or similar vehicdes must be in accordance with the national wiring rules
Images on previous page refer to EP-2430, EPL-3620, EPI-4815 & EPI-4835
1 | **** |
---|---|
2 | **** |
3 | **** |
4 | Interlock Connection – the interlock cable connections provide a |
normally open or normally closed circuit with no voltage, which change state
when the charger is operational.
| 4a| Normally open
4b| Normally closed
4c| Common
5| ****
WARNING
- .Please make sure the battery connection cables are correctly connected to the charger terminals before operating the charger
- Always connect the positive cable to the battery first, then the negative cable to the negative (chassis for negative grounded vehidles) prior to conneting to supply mains.
- After charging, and when removing charger, always disconnect the battery charger from the supply mains, then disconnect the negative/chassis connection and then the positive connection.
- Supply mains wiring in fixed installs such as caravans or similar vehicles must be in accordance with the national wiring rules.
1 | AC Input |
---|---|
2 | Red = Positive |
DC Battery Connection Black = Negative
White = Temp. Sens
3| Brake Switch When AC has power – open circuit When AC has
NO power – closed circuit
4| Charger Switch Open circuit – charger ON Closed circuit –
charger OFF
5| Remote LED
MAINTENANCE INSTRUCTIONS
- Do not expose the charger to oil, dirt, mud or direct heavy water spray when cleaning vehicle.
- The enclosure of the charger has been tested successfully to EN60529, meeting IP66 compliance.
- If the detachable AC input power supply cable is damaged, replace with a cable that is a safety approved detachable cable, 3 conductor, 1.5 mm² minimum, and rated appropriate for use in the country of destination. AC input type to the charger is, type IEC 60320 C14 plug.
FAULT INDICATION
FAULT INDICATION
When a fault occurs, LED2(100%)/LED3(75%)/LED4(50%)will blink at the same
time.
Blinking Frequency (every 4 sec) | Fault Cause | Solution |
---|---|---|
The battery is not connected or the battery voltage is too low | 1) Check |
battery connection is correct.
-
Check charger connection is correct.
-
Check each battery is good.
2.
|
Abnormal AC Power Input (Voltage)
| 1) Check AC input cord is connected between charger and AC outlet.
- Make sure AC plug is tightly inserted into AC outlet.
3.
|
Charger High Temperature Protection
| 1) Charger shuts down and enters protection mode due to charger/environmental temperature is too high. Please place the charger in a well ventilated environment.
- Disconnect the charger and wait for 15-20 mins before reconnecting for charging.
4.
|
Battery High Temperature Protection
| 1) Charger will reduce output current and stop charging when the battery temperature exceeds 50°.
- When the battery temperature drops, the charger will reset automatically.
5.| Output Current is too large| Return to the factory for repair.
6.| Battery Voltage is too high| Check and assure that the correct
output battery voltage
is connected.
WITH DIGITAL DISPLAY
Blinking Frequency | Fault Cause | Solution |
---|
E01 bAt
| The battery is not connected or the battery is in reverse or the battery is damaged| 1) Check battery connection is correct.
-
Check charger connection is correct.
-
Check each battery is good.
E02 AC
| ****
Abnormal AC Power Input (Voltage)
| 1) Check AC input cord is connected between charger and AC outlet.
- Make sure AC plug is tightly inserted into AC outlet.
E03 Hot
| ****
Charger High Temperature Protection
| 1) Charger shuts down and enters protection mode due to charger/environmental temperature is too high. Please place the charger in a well ventilated environment.
- Disconnect the charger and wait for 15-20 mins before reconnecting for charging.
E04 bAt
| ****
Battery High Temperature Protection
| 1) Charger will reduce output current and stop charging when the battery temperature exceeds 50°.
- When the battery temperature drops, the charger will reset automatically.
E05 Err| Internal error in product| Return to the factory for
repair.
E06 bAt| Battery Voltage is too high| Check and assure that the
correct output battery voltage
is connected.
WATERPROOFING INSTALLATION
Waterproof ring installation of the AC input cable.
- Slip waterproof ring or grommet over the AC input cable
- Connect the AC input cable into the charger ensuring the waterproofing ring is seated correctly
Firmly tighten the waterproofing clamp using a Phillips head screw driver
*NOTE: Take care to not overtighten the waterproof clamp.
SPECIFICATIONS
Model: | EPI-2430 | EPI-3620 | EPI-4815 | EPI-4835 | EPI-4860 |
---|
DC Output
Voltage-nom (VDC)| 24V| 36V| 48V| 48V| 48V
Voltage-max (VDC)| 34V| 51V| 68V| 68V| 68V
Current-max (A)| 30A| 20A| 15A| 35A| 60A
Applicable to Battery| AGM, Flooded, GEL, Lithium
Reverse Polarity| Electronic Protection – auto – reset
Short Circuit| Electronic Protection – auto – reset
AC Input
Voltage Range (VAC)| 100 – 240AC| 180 – 240VAC| 220 – 240VAC
Frequency (Hz)| 50 – 60Hz| 50 – 60Hz
Power max (W)| 850W| 1985W| 3400W
Current max (A)| 8.5A| 10A| 15A
Dimensions| 20.7 x 18.0 x 16.0 cm| 19.5 x 18.0 x 19.5 cm| 35.9 x 28.0 x 10.7
cm
Weight| 4.6 kg| 5.2 kg| 10 kg
Operating Temperature| -20C ~ +50C| -20C ~ +50C| -20C ~ +50C
Storage Temperature| -40C ~ +70C| -40C ~ +70C| -40C ~ +70C
*IP Rating: IP66 when AC input waterproof ring/grommet is used.
Note: Specifications are subject to change without notices.
CHARGE PROFILE
Charge Profile Instructions:
Changing the Charge Profile on the Enerdrive ePOWER Industrial Charger The
ePOVWER Industrial charger has the ability to be programmed with a charge
profile (algorithm) to suit any battery. The default charge profile that comes
installed on the charger is b02. This charge profile is suited for Trojan T105
batteries. You can change the charge profile installed on the charger at any
time via the USB port on the front of the charger.
NOTE: You will requirea formatted (FAT32) USB memory stick with a
capacity of 1024KB or larger.
Please carefully follow the steps below to change the charge profile:-
- Download and save the Battery Algorithm Listing from the download link www.enerdrive. com.au/Algorithm/ePOWER-algorithm.xlsx
- Select a charge profile that matches the batteries you are using from the “Charge Profile Listing” tab in this spreadsheet
- Right click on the selected Charge Profile in the “Charge Profile” column and click “Copy”.
- Now “Paste” the copied charge profile to your formatted USB memory stick.
- Make sure the charger is NOT connected to the battery or AC power.
- Unscrew the round cap covering the USB port on the front of the charger and insert the USB memory stick.
- Plug the AC power cord into the charger and switch ON AC power.
- Please allow up to 1 min for programming.Programming is complete once USB status LED is “SOLID”.
- Switch OFF AC power to the charger.
- Remove USB memory stick and screw USB cap back on.
- Switch ON AC power to the charger and check the charge profile you selected has been installed. The charger will display the installed charge profile as a series of flashes of the Battery Capacity LED’S. See user manual for explanation.
- Switch OFF AC power to the charger.
- Connect the charger to the DC battery.
- Switch ON the AC power to the charger to begin charging with the instaled charge profle.
The ePOWER Industrial charger can also be programmed with a custom (user
defined) charge profle for batteries that are not listed. If you cannot find a
suitable charge profile for your batteries please contact Enerdrive.
PLEASE NOTE : ALL relevant battery charging specifications MUST be
supplied in order for us to be able to areate a custom charge profle for you.
See following page for the Charge Profile Table.
Charge Profile Table:
Algorithm No. | Manufacturer | Model | Batt Type | Ah_C20 |
---|---|---|---|---|
b38 | Custom Setup | Custom Setup | Custom | Custom |
b01 | Common | Flooded | 300 | |
b02 | Trojan | TROJAN T105 | Flooded | 225 |
b04 | Discover | Discover AGM | AGM | 250 |
b05 | US | US battery Flooded | Flooded | 250 |
b06 | Trojan | Trojan 30XHS | Flooded | 130 |
b07 | Trojan | Trojan T125 | Flooded | 240 |
b08 | Trojan | Trojan J305 | Flooded | 330 |
b10 | Trojan | Trojan T145 | Flooded | 260 |
b11 | Trojan | Trojan T1275 | Flooded | 150 |
b12 | Discover | Discover DGC6A-220D AGM | AGM | 220 |
b13 | Trojan | Trojan T605 | Flooded | 210 |
b18 | Trojan | Trojan T875 Flooded | Flooded | 170 |
b19 | US | US2000 Flooded | Flooded | 216 |
b20 | US | US2200 Flooded | Flooded | 232 |
b21 | US | US250hc Flooded | Flooded | 280 |
b25 | Fullriver | Fullriver DC224-6 AGM | Flooded | 224 |
b27 | Trojan | Trojan L16P-AC Flooded | Flooded | 420 |
b28 | Common | Generic 200-370Ah AGM | AGM | 300 |
b29 | US | US.8VGCXC2 Flooded | Flooded | 170 |
b30 | US | US. 12VXC2 Flooded | Flooded | 155 |
b31 | US | US 305XC Flooded | Flooded | 310 |
b32 | US | US 125 XC2 FLA | Flooded | 242 |
b33 | US | US 145 XC2 FLA | Flooded | 251 |
b34 | Crown | Crown CR-235 FLA | Flooded | 235 |
b35 | Crown | Crown CR-245 FLA | Flooded | 245 |
WARRANTY
5 Year Warranty
In the unlikely event that a technical issue arises with an Enerdrive product,
customers are encouraged to initially contact the Enerdrive Support Team on
1300 851 535 or support@enerdrive.com.au
for immediate and efficient expertise and first class product support.
Important Note: Consumer Protections
If you have purchased your product in Australia, you should be aware that:
This warranty is provided in addition to other rights and remedies held by a
consumer at law. Our goods come with guarantees that cannot be excluded under
the Australian Consumer Law. You are entitled to a replacement or refund for a
major failure and for compensation for any other reasonably foreseeable loss
or damage. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a
major failure. Enerdrive warrants that its Products will be free from defects
in materials and workmanship (subject to limits, and in normal conditions, as
described in the complete Enerdrive Warranty Policy) for up to 5 years from
the date of purchase. For full terms, conditions and claim process, refer to
the Enerdrive website. https://enerdrive.com.au/warranty/
DOMETIC POWER & CONTROL (ENERDRIVE) PTY LTD P.O. Box 9159, Wynnum Plaza,
Queensland, Australia 4178 Ph: 1300 851 535 / Fax: 07 3390 6911
Email: support@enerdrive.com.au
Web: www.enerdrive.com.au
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>