ZUG CombiSteamer V6000 45L Grand Steamer Installation Guide

June 9, 2024
ZUG

ZUG CombiSteamer V6000 45L Grand Steamer

Product Information

Product Name: CombiSteamer V6000 45L Grand

Model Number: 1069252-04

Electrical Connection: Must be carried out by competent personnel according to the rules and standards for low voltage installations and according to the requirements of the local electric utility. An appliance supplied ready with a plug must be connected only to an earthed wall socket properly installed according to regulations.

Installation Requirements: An all-pole mains disconnect device with 3 mm contact gaps must be installed for domestic electrical installations. Proper earthing and separately routed neutral and protective conductors provide for a safe and trouble-free operation.

Ventilation Requirements: The niche and gap dimensions given in the manual must be observed to ensure proper ventilation. For installation in inflammable materials, observe the rules and standards for fire protection.

Altitude Performance: If used at an altitude of over 2,000 meters, a reduced performance must be expected.

Modification: Only service personnel is permitted to modify the appliance (incl. inlet and outlet lines and mains cable).

Product Usage Instructions

Always wear gloves when handling unpacked appliances. Do not lift the appliance by the operating panel or the door handle. Do not indent sides or top of the appliance and do not tip over the appliance.

Check the rating plate for required supply voltage, type of current, and fuse protection before electrical connection.

Connect the appliance using H05VV-F (Td) or CH-N1VV-U (TT) cable or H07V-U (T) installation wires in an insulating sleeve. The connection cable should measure at least 150 cm from the point where it comes out of the wall.

If used at an altitude of over 2,000 meters, expect reduced performance.

Observe all local regulations and the rules and standards for fire protection when installing the appliance in inflammable materials.

Only service personnel is permitted to modify the appliance (incl. inlet and outlet lines and mains cable).

Installation instructions
CombiSteamer V6000 45L Grand, all devices

Safety precautions

Electrical connections must be carried out by competent personnel according to the rules and standards for low voltage installations and according to the requirements of the local electric utility. An appliance supplied ready with a plug must be connected only to an earthed wall socket properly installed according to regulations. For domestic electrical installation, an all-pole mains disconnect device with 3 mm contact gaps must be installed. Switches, plug connections, MCBs and safety fuses that are freely accessible after installation of the appliance and that switch all poles are regarded as permissible isolating devices. Proper earthing and separately routed neutral and protective conductors provide for a safe and trouble-free operation. After completion of the installation, it must not be possible to touch live parts or cables with operational insulation. Check existing installations. Check rating plate for required supply voltage, type of current and fuse protection. Electrical connection using H05VV-F (Td) or CH-N1VV-U (TT) cable or H07V-U (T) installation wires in an insulating sleeve. The connection cable should measure at least 150 cm from the point where it comes out of the wall.

Warning
Always wear gloves when handling unpacked appliances. Do not lift appliance by the operating panel or the door handle. Do not indent sides or top of appliance and do not tip over appliance. The niche and gap dimensions given below must be observed to ensure proper ventilation. If used at an altitude of over 2,000 metres, a reduced performance must be expected. Only service personnel is permitted to modify the appliance (incl. inlet and outlet lines and mains cable).
Observe all local regulations. For installation in inflammable materials, observe the rules and standards for fire protection.

Installed in tall unit

ZUG-CombiSteamer-V6000-45L-Grand-Steamer-
fig-1

  • 1-phase mains cable without plug
  • Mains cable with plug

Installation in double niche

ZUG-CombiSteamer-V6000-45L-Grand-Steamer-fig-4

The appliance must be installed in a de-energized stateZUG-
CombiSteamer-V6000-45L-Grand-Steamer-fig-8

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals