Installation instructions           Combair/CombiSteamer/Steamer, all

devices

Safety precautions

Electrical connections must be carried out by competent personnel according to the rules and standards for low voltage installations and according to the requirements of the local electric utility. An appliance supplied ready with a plug must be connected only to an earthed wall socket properly installed according to regulations. For domestic electrical installation, an all-pole mains disconnect device with 3 mm contact gaps must be installed. Switches, plug connections, MCBs and safety fuses that are freely accessible after installation of the appliance and that switch all poles are regarded as permissible isolating devices. Proper earthing and separately routed neutral and protective conductors provide for a safe and trouble-free operation. After completion of the installation, it must not be possible to touch live parts or cables with operational insulation. Check existing installations. Check rating plate for required supply voltage, type of current and fuse protection. Electrical connection using H05VV-F (Td) or CH-N1VV-U (TT) cable or H07V-U (T) installation wires in an insulating sleeve. The connection cable should measure at least 150 cm from the point where it comes out of the wall.

Always wear gloves when handling unpacked appliances. Do not lift appliance by the operating panel or the door handle. Do not indent sides or top of appliance and do not tip over appliance. For proper ventilation, prepare appliance niche with an air intake opening of at least 25cm². If used at an altitude of over 2,000 metres, a reduced performance must be expected. Only service personnel is permitted to modify the appliance (incl. inlet and outlet lines and mains cable).

Observe all local regulations. For installation in inflammable materials, observe the rules and standards for fire protection.

21048, 21049, 21050, 21058, 21059, 21067, 21070, 23026, 23031, 23032, 23041, 23043, 23047

Installed in tall unit

V-ZUG V2000 45 Combair Oven A1

1-phase mains cable without plug

230 V~ 16 A

L1 brown
N blue
PE yellow/green

Mains cable with plug

Above oven/steamer

EURO

Below oven/steamer

EURO

Above warming drawer

EURO

The appliance must be installed in a de-energized state

Check perpendicularity of niche.

Check appliance/fasteners

Check connected loads

For installation, connected loads must correspond

Place appliance in front of the niche

Connect cable V-ZUG V2000 45 Combair Oven B5b

Connect cable to connecting terminals in accordance with connection plate

Push completely in and align appliance

Secure appliance to niche

4x

Frontal for 60 cm wide appliance

Carry out function and safety checks

Demo mode switched off? If not, switch off in service menu with password 6301.