CHAUVET DJ Intimidator Spot 360X IP User Guide

June 9, 2024
Chauvet DJ

DJ Intimidator Spot 360X IP
User GuideCHAUVET DJ Intimidator Spot 360X IP

About This Guide

The Intimidator Spot 360X IP Quick Reference Guide (QRG) has basic product information such as mounting, menu options, and DMX values. Download the User Manual from www.chauvetdi.com for more details. Disclaimer The information and specifications contained in this QRG are subject to change without notice.

LIMITED WARRANTY

FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers In the United States and Mexico: www.chauvetlighting.com /warrantv-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu /warrantv-registration. Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES.
This warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.

Safety Notes

These Safety Notes include important information about installation, use and maintenance.

  • **** ONLY connect this product to a grounded and protected circuit.

  • DISCONNECT from power before cleaning or replacing the fuse.

  • DO NOT look at the light source when the product is on.

  • Make sure the power cord is not crimped or damaged.

  • Never disconnect this product from power by pulling on the cord.

  • When mounting this product overhead, ALWAYS use a safety cable.

  • DO NOT allow flammable materials close to the product when it is operating.

  • DO NOT touch the product’s housing when it is on because it will be hot. The voltage of the outlet to which you are connecting this product must be within the range stated on the decal or rear panel of the product.

  • DO NOT open this product. It contains no user-serviceable parts.

  • DO NOT submerge this product (IP65). Regular outdoor operation is fine.

  • Not for permanent outdoor installation in locations with extreme environmental conditions.
    This includes, but is not limited to:

  • Exposure to a marine/saline environment (within 3 miles of a saltwater body of water).

  • Where the normal high or low temperatures of the location exceed the temperature ranges in this manual.

  • Locations that are prone to flooding or being buried in snow.

  • Other areas where the product will be subject to extreme radiation or caustic substances

  • Always mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.

  • Be sure that no ventilation slots on the unit’s housing are blocked.

  • Never connect this product to a dimmer or rheostat.

  • Never carry the product by the power cord. Use only the hanging bracket or handle to carry this product.

  • The maximum ambient temperature is 104 T (40 °C). Do not operate this product at higher temperatures.

  • In the event of a serious operating problem, stop using immediately.

  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Contact

Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or return a product. Refer to Contact Us at the end of this QRG for contact information.
What is Included

  • Intimidator Spot 360X IP
  • Flanging bracket
  • Power cord
  • Quick Reference Guide

To Begin Unpack your Intimidator Spot 360X IP and make sure you have received all parts in good condition. If the box or contents appear damaged, notify the carrier immediately, not Chauvet.
AC Power
This product has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz.
To eliminate wear and Improve Its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
Power Linking
It is possible to power link up to 5 Intimidator Spot 360X IP products on 120 V or 9 products on 230 V. Never exceed this number. Power-linking cords can be purchased separately.
Fuse Replacement

  1. Disconnect the product from power.
  2. Using a flat-head screwdriver, unscrew the fuse holder and pull straight out.
  3. Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating.
  4. Re-insert the fuse holder and reconnect power.

Mounting
Before mounting this product, read the Safety Notes.
Mounting DiagramCHAUVET DJ Intimidator Spot 360X IP - Mointing
Diagram

Control Panel Description

Button Function
Exits from the current menu or function
Navigates upwards through the menu list and increases the numeric value

when in a function

| Navigates downwards through the menu list and decreases the numeric value when in a function | Enables the currently displayed menu or sets the currently selected value into the selected function

Menu Map
Refer to the Intimidator Spot 360X IP product page on www.chauvetdj.com for the latest menu map.

Main Level Programming Levels Description
Address 001-512 Sets the DMX startin g address
Run Mode DMX 14CH

8CH
Slave| Slavel-4| Selects Slave mode 1, 2, 3, or 4
Auto| Selects Auto mode
Sound| Selects Sound-Active mode
RF| RF 1-4| Sets the product to work with the RFC-XL remote in group 1, 2, 3, or 4
(RF remote must be bound to the product first)
RFP| Sets the product to work with public RF signal
Manual| Pan| 000-255| Manual pan control
Tilt| Manual tilt control
Color| Manual color control
Gobo| Manual rotating gobo control
Gobo
Rotate| Manual gobo rotation control
Prism| Manual prism control
Focus| Manual focus control
Dimmer| Manual dimmer control
Shutter| Manual shutter control
Setup| Pan Reverse| OFF| Normal pan operation
ON| Reverse pan operation
Tilt Reverse| OFF| Normal tilt operation
ON| Reverse tilt operation
Screen Reverse| OFF| Normal display
ON| Reverse display
AUTO| Automatic display orientation
Pan Angle| 540| Selects the 540° pan angle range
360| Selects the 360° pan angle range
180| Selects the 180° pan angle range
Tilt Angle| 270| Selects the 270° tilt angle range
180| Selects the 180° tilt angle range
90| Selects the 90° tilt angle range
Totem Mode| OFF| Does not restrict the pan and tilt motion
UP| Restricts the pan and tilt motion for overhead mounting
DOWN| Restricts the pan and tilt motion for surface/floor mounting
Sensitivity| 001-100| Sets sound sensitivity
DMX Loss| Hold| Holds the last setting when signal is lost
Black| Blacks out the product when signal is lost
Auto| Sets the unit to Auto mode when signal is lost
Sound| Sets the unit to Sound mode when signal is lost
USB Update| Yes| Enables/disables software update through USB-C
No
RF| Bind| Shows instructions on how to bind the RF remote to the product
Reset| Resets the product
Factory Set| Loads factory defaults
Sys Info| Ver:| V| Displays the firmware version
Running Mode:| |   Displays the current running mode
DMX Address:| | Displays the current DMX address
Temperature:| | Displays the current product temperature
LED FAN:| | Displays LED fan information
Base Fan1:| | Displays base fan information

DMX Linking
The Intimidator Spot 360X IP can work with a DMX controller. Instructions for connecting and configuring this product for DMX operation are in the User Manual. If you are not familiar with DMX, download the DMX Primer from www.chauvetdj.com.
Starting Address
To ensure full access to all channels available in each DMX mode, the highest recommended DMX address is 499.
Master/Slave Connection
The Intimidator Spot 360X IP uses the DMX data connection for its Master/Slave mode. Information about configuring the Intimidator Spot 360X IP for Master/Slave operation is in the User Manual, which is available from the Chauvet website.
RF Remote
The Intimidator Spot 360X IP can be operated with the CHAUVET RFC or RFC-XL remotes. For more information about the RF Remote, download instructions for the Intimidator Spot 360X IP User Manual from www.chauvetdj.com.
GobosCHAUVET DJ Intimidator Spot 360X IP - Gobos

DMX Values

8Ch 14Ch Function Value Percent/Setting
1 1 Pan 000 255 0-540′
2 Pan fine 000 255 Fine control of panning
2 3 Tilt 000 255 0-270′
4 Tilt fine 000 255 Fine control of tilting
5 Pan/tilt speed 000 255 Pan/Tilt speed. fast to slow
3 6 Color wheel 000 006 White
007 013 Red
014 020 Orange
021 027 Yellow
028 034 Green
035 041 Blue
042 048 CTO
049 055 Cyan
056 062 Magenta
063 064 White
065 189 Color indexing
190 221 Color cycling rainbow. fast to slow
222 223 Stop
224 255 Reverse color cycling rainbow, slow to fast
4 7 Gobo wheel (see (Mbns) 000 007 Open
008 015 Gobo 1
016 023 Gobo 2
024 031 Gobo 3
032 039 Gobo 4
040 047 Gobo 5
048 055 Gobo 6
056 063 Gobo 7
064 071 Gobo 7 shake slow to fast
072 079 Gobo 6 shake slow to fast
080 087 Gobo 5 shake slow to fast
088 095 Gobo 4 shake slow to fast
096 103 Gobo 3 shake, slow to fast
104 111 Gobo 2 shake, slow to fast
112 119 Gobo 1 shake. slow to fast
120 127 Open
128 189 Cycle effect. slow to fast
190 193 Stop
194 255 Reverse cycle effect slow to fast
5 8 Gobo rotation 000 063 Gobo indexing
064 145 Gobo rotation. slow to fast
146 149 Stop
150 231 Reverse gobo rotation. slow to fast
232 255 Gobo bounce. short to long
6 9 Prism 000 003 No function
--- --- --- --- ---
004 4D 006 3-facet prism
007 065 Prism rotation. slow to fast
660 123 Reverse prism rotation. slow to fast
124 127 3-facet prism
128 131 No function
132 134 5-facet prism
135 193 Prism rotation. slow to fast
194 251 Reverse prism rotation. slow to fast
252 255 5-facet prism
7 10 Focus 000 255 Focus
11 Dimmer 000 255 0-100%
8 12 Strobe 000 003 Off
004 007 On
008 076 Strobe. slow to fast
077 145 Pulse strobe. slow to fast
146 215 Random strobe. slow to fast
216 225 On
13 Function 000 007 No function
008 015 Blackout on pan/tilt movement
016 023 Blackout on color wheel movement
024 031 Blackout on gobo wheel movement
032. 039 Blackout on paratitUcolor wheel movement
040 047 Blackout on pan/tilt/gobo wheel movement
048 055 Blackout on peNtilticolor wheel/gobo wheel movement
056 095 No function
096 103 Pan reset
104 111 Tit reset
112 119 Color wheel reset
120 ****127 Gobo wheel reset
128 • 135 No function
136 143 Prism reset
144 m 151 Focus reset
152 159 All reset
160 255 No function
14 Movement macros 000 007 No function
008 023 Movement macro 1
240 039 Movement macro 2
040 055 Movement macro 3
056. 071 Movement macro 4
072 087 Movement macro 5
088.103 Movement macro 6
104 119 Movement macro 7
120 135 Movement macro 8
136 151 Sound-active movement macro 1
152 167 Sound-active movement macro 2
168 183 Sound-active movement macro 3
184 199 Sound-active movement macro 4
200 215 Sound-active movement macro 5
216 231 Sound-active movement macro 6
232 247 Sound-active movement macro 7
248 255 Sound-active movement macro 8

Contact Us

General Information Technical Support
Chauvet World Headquarters
Address. 5200 NW 108th Ave. Sunrise, FL 33351
Voice: 954-577-4455
Fax: 954-929-5560
Toll Free: 800-762-1084
Voice: 844-393-7575 Fax: 954-756-8015
Email. chativetcs@cehativetlichtinn.com
Website: www.chauveta.com
Chauvet U.K.
Address: Unit 1C Brookhill Road Industrial Estate
Pinxton, Nottingham. UK NG16 6NT
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110
Email: UKtech@achauvetlightina.eu
Website: www.chauvetdi.eu
Chauvet Benelux
Address: Stokstraat 18 9770
Kruishoutem Belgium Voice: +32 9 388 93 97
Email: BNLtech@chauvetlighting.eu
Website: www.chauvetdi.eu
Chauvet France
Address: 3. Rue Ampere 91380 Chilly-Mazarin France Voice: +33 1 78 85 33 59
Email: FRtech@chauvetlighting.fr
Website: www.chauvetdi.eu
Chauvet Germany
Address: Bruno-BUrgel-Str. 11 28759
Bremen Germany Voice: +49 421 62 60 20
Email: DEtech@echauvetliohtinh.de
Website: www.chauvetdi.eu
Chauvet Mexico
Address: Av. de las Partidas 34 – 38 (Entrance by Calle 2)
Zona Industrial Lerma Lerma, Edo. de Mexico. CP 52000 Voice: +52 728-690-2010
Email: serviciolachauvet.com.mx
Website: www.chauvetdi.mx
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact the dealer of record.
Follow the instructions to request support or to return a product. Visit our website for contact details.
Intimidator Spot 360X IP QRG ML6 Rev. 1
© Copyright 2022 Chauvet All rights reservedCHAUVET DJ Intimidator Spot 360X
IP - icon

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Chauvet DJ User Manuals

Related Manuals