CHAUVET DJ COREpar UV120 ILS User Guide

June 3, 2024
Chauvet DJ

Quick Reference Guide

About This Guide
The COREpar UV120 ILS Quick Reference Guide (QRG) has basic product information such as mounting, menu options, and DMX values. Download the User Manual from www.chauvetdj.com for more details.
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.

LIMITED WARRANTY

FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE. For Customers in the United States and Mexico: www.chauvetliahtina.com/warrantv-reaistration. For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu/warranty-registration.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.

Safety Notes

These Safety Notes include important information about installation, use, and maintenance.

  • ONLY connect this product to a grounded and protected circuit.
  • DISCONNECT from power before cleaning or replacing the fuse.
  • DO NOT look at the light source when the product is on.
  • Make sure the power cord is not crimped or damaged.
  • Never disconnect this product from power by pulling on the cord.
  • When mounting this product overhead, ALWAYS use a safety cable.
  • DO NOT allow flammable materials close to the product when it is operating.
  • DO NOT touch the product’s housing when it is on because it will be hot.
  • The voltage of the outlet to which you are connecting this product must be within the range stated on the decal or rear panel of the product.
  • This product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose this product to rain or moisture.
  • Always mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
  • Be sure that no ventilation slots on the unit’s housing are blocked.
  • Never connect this product to a dimmer or rheostat.
  • Replace the fuse with the same type and rating.
  • Never carry the product by the power cord. Use only the hanging bracket or handle to carry this product.
  • The maximum ambient temperature is 104 °F (40 °C). Do not operate this product at higher temperatures.
  • In the event of a serious operating problem, stop using immediately.
  • DO NOT open this product. It contains no user-serviceable parts.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or return a product. Refer to Contact Us at the end of this QRG for contact information.
What is Included

  • COREpar UV120 ILS
  • Power cord
  • Magnetic lens
  • Quick Reference Guide

To Begin
Unpack your COREpar UV120 ILS to make sure you have received all parts in good condition. If the box or contents appear damaged, notify the carrier immediately, not Chauvet.

AC Power
This product has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz.
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Power Linking
It is possible to power link up to 5 COREpar UV120 ILS products on 120 V or 9 products on 230 V. Never exceed this number. Power-linking cords can be purchased separately.
Fuse Replacement

  1. Disconnect the product from power.
  2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
  3. Pry the safety cap out of the housing.
  4. Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the exact same type and rating.
  5. Re-insert the fuse holder and reconnect power.

Mounting

Before mounting this product, read the Safety Notes.
Mounting Diagram

Control Panel Description

Button Function
Exits from the current menu or function
Navigates upwards through the menu list and increases the numeric value

when in a function

| Navigates downwards through the menu list and decreases the numeric value when in a function | Enables the currently displayed menu or sets the currently selected value into the selected function

Menu Map
Refer to the COREpar UV120 ILS product page on www.chauvetdj.com for the latest menu map.

Main Level Programming Levels Description
1-Ch d 1-512 1-channel DMX mode
5-Ch d 1-508 5-channel DMX mode
iLS iLS 1-4 Sets ILS mode

P–
(Automatic
program)| P 1| Pulse effect 0-100%-0
P 2| Pulse effect 0-100%
P 3| Pulse effect 100%-0
S–| S. 1-100| Automatic program speed
Snd
(Sound-active)| Snd1| Sets sound active mode
Snd2
SEnS| u 0-100| Sound sensitivity
u….
(Dimmer)| d. 0-255| Manual Dimmer
diM
(Dimmer speed)| oFF| Sets the dimmer speed
diM1
diM2
diM3
SEt
(Infrared)| ir| on| Enables/disables infrared control
off
rESt| yes| Reset to factory default
 no
Temp| | Shows the temperature

DMX Linking
The COREpar UV120 ILS can work with a DMX controller. Instructions for connecting and configuring this product for DMX operation are in the User Manual. If you are not familiar with DMX, download the DMX Primer from www.chauvetdj.com.
Starting Address
To ensure full access to all channels available in each DMX mode, the highest recommended DMX address is 508.
Master/Slave Connection
The COREpar UV120 ILS uses the DMX data connection and ILS for its Master/Slave mode. Information about configuring the COREpar UV120 ILS for Master/Slave operation is in the User Manual, which is available from the Chauvet website.
ILS Connection
The COREpar UV120 ILS uses the DMX data connection and the D-Fi USB for wireless connection to the Integrated Lighting System (ILS) ecosystem (patent pending). For more information about configuring the COREpar UV120 ILS into ILS mode, please refer to the User Manual available at www.chauvetdj.com.
IRC-6
The COREpar UV120 ILS can be operated with the CHAUVET IRC-6. For more information about the IRC-6, download instructions for the IRC-6 or the COREpar UV120 ILS User Manual from www.chauvetdj.com.

Button Function
Turns LEDs on/off
Enables pulse modes
Enables sound active mode
Increases and decreases speed
Adjusts sound sensitivity
Adjusts dimmer
<+> Increases values for controls as described above
<-> Decreases values for controls as described above

D-Fi USB Connectivity
The COREpar UV120 ILS is able to become a D-Fi wireless receiver/transmitter with the use of the D-Fi USB from CHAUVET DJ. Simply set the DIP switch D-Fi receiving/transmitting channel, plug it into the USB port then set the product’s DMX Personality and DMX Address. Further instructions for connecting and configuring this product for D-Fi USB operation are in the User Manual.
WARNING! DO NOT plug anything other than a D-Fi USB into the USB port. Doing so may cause damage to the product.
Once plugged in, the D-Fi USB will take over the product. Wired DMX and manual display control/menu buttons will be unavailable until you unplug the D-Fi USB. The priority levels are:

  1. D-Fi USB
  2. Wired DMX
  3. IRC-6 Remote Control
  4. Manual Digital Display/Menu Buttons

DMX Values

1-Ch 5-Ch Function Value Percent/Setting
1 1 UV 000 ⇔ 255 0-100%
2 Strobe
(When CH3 is 000-031) 000 ⇔ 015 No function
016 ⇔ 255 Slow to fast
Program Speed (When CH3 is 032-223) 000 ⇔ 255 Slow to fast
Sound Sensitivity (When CH3 is 224-255) 000 ⇔ 010 No function
011 ⇔ 255 low to high sensitivity
3 Programs 000 ⇔ 031 No function
032 ⇔ 095 Pulse effect 0-100%
096⇔159 Pulse effect 100%-0
160 ⇔ 223 100%-0-100%
224 ⇔ 240 Sound sensitivity 1
241 ⇔ 255 Sound sensitivity 2
4 Dimmer 000 ⇔ 255 0-100%
5 Dimmer Speed 000 ⇔ 051 Dimmer speed set from menu options
052 ⇔ 101 Dimmer speed mode off
102 ⇔ 152 Dimmer speed fast
153 ⇔ 203 Dimmer speed medium
204 ⇔ 255 Dimmer speed slow
General Information Technical Support
Chauvet World Headquarters

Address: 5200 NW 108th Ave.
Sunrise, FL 33351
Voice: 954-577-4455
Fax: 954-929-5560
Toll Free: 800-762-1084| Voice: 844-393-7575
Fax: 954-756-8015
Email: chauvetcs@chauvetlighting.com
Website: www.chauvetdj.com
Chauvet Europe Ltd|
Address: Unit 1C
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK
NG16 6NT
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110| Email: UKtech@chauvetlighting.eu
Website: www.chauvetdi.eu
Chauvet Europe BVBA|
Address: Stokstraat 18
9770 Kruishoutem
Belgium
Voice: +32 9 388 93 97| Email: BNLtech@chauvetlighting.eu
Website: www.chauvetdj.eu
Chauvet France|
Address: 3, Rue Ampere 91380 Chilly-Mazarin
France
Voice: +33 1 78 85 33 59| Email: FRtech@chauvetlighting.fr
Website: www.chauvetdi.eu
Chauvet Germany|
Address: Bruno-Burgel-Str. 11
28759 Bremen
Germany
Voice: +49 421 62 60 20| Email: DEtech@chauvetlighting.de
Website: www.chauvetdj.eu
Chauvet Mexico|
Address: Av. de las Partidas 34 – 3B
(Entrance by Calle 2)
Zona Industrial Lerma
Lerma, Edo. de Mexico, CP 52000
Voice: +52 728-690-2010| Email: servicio@chauvet.com.mx
Website: www.chauvetdj.mx

Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U.K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.

COREpar UV120 ILS QRG ML6 Rev. 2
© Copyright 2022 Chauvet
All rights reserved

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Chauvet DJ User Manuals

Related Manuals