WHAT’S INCLUDED

  • Vehicle Specific Wire Harness (P-BUA-ESCAPE)
  • 6” Cable Ties
  • Adhesive Cable Tie Mounts
  • 1/2” Self Tapping Screw

COMPATIBLE ACCESSORIES

  • 97dB Backup Alarm (BUA-97C)
  • 97dB White Noise Backup Alarm (BUA-97WNC)

TOOLS REQUIRED

  1. 7mm Nut-setter
  2. 10mm Nut-setter
  3. T-25 Bit
  4. 2 Phillips Bit

  5. Knife
  6. Diagonal Cutters
  7. Wire Strippers/Crimper’s
  8. Panel Removal Tool
  9. Impact Drill

INSTALLATION INSTRUCTION

STEP 1
Remove the following cargo space panels

  • Floor Panel
  • Left and Right cargo space storage compartments and their contents
  • Liftgate striker cover (see photo in step 2 for reference)

STEP 2
Use a T-25 bit to remove the cargo space tie down bolts and a 7mm bit to remove the cargo space scuff plate trim panel bolts. Then us a panel removal tool to pry up the clips that are holding the scuff plate in place so it may be removed.

STEP 3
Use a panel removal tool to unclip the passenger (A.) and driver (B.) side rear quarter panels

STEP 4
Locate the vehicle’s Green/Brown (A.) wire that is located in the harness above the rear passenger wheel well (B.)

STEP 5
Cut the vehicle’s reverse wire in half and splice in/ crimp the backup alarm harness to the vehicle’s wiring. Then use the supplied 1/2” self tapping fastener to ground the ring terminal of the harness to the vehicle chassis.

STEP 6
Route the backup alarm harness across the backside the cargo space compartment from the passenger side (A.) to the driver side using the provided cable ties and cable tie mounts (B.).

STEP 7
Use a knife to make a small incision in the driver side floor grommet, so that the backup alarm harness connector may pass through it

STEP 8
Use an impact drill and 10mm nut-setter to install a compatible backup alarm on the underside of the vehicle. Then plug the backup alarm connector into the mating connector on the P-BUA-ESACAPE harness and secure any loose wiring.

Note: (2) 10mm TEK screws are provided with the compatible backup alarm

STEP 9
Test the backup alarm before re-installing all factory panels and load space compartments. Note: Be careful not to pinch any wires when re-installing panels.