ML-400 Electric Lock
Installation Instruction
Specifications
- Operating Voltage: 12 ~ 24 VDC/AC
- Current Draw: 280mA/12VDC; 180mA/24VDC
- Locking Mode: Fail-Safe
- Operating Temperature: -10°C~+49°C
- Humidity: 0~85% non-condensing
- Applicable to horizontal and vertical installation
- For single/double action swing doors
- Latch Throw: 16mm
- Endurance Rating: 250,000 cycles (Factory tested)
- Static strength: 1,500 lbs
- Preload: 500 lbs of pressure strength
ML-400 Series Models
ML-400M: Mortise mount
ML-400MSMB: Surface mount
ML-400MVGL: Surface mount (for frameless glass doors & walls)
Mortise Mount Model Dimensions
Strike Plate Dimensions
Wiring Diagram
Butt Splice (IDC) Connector
Using crimper or pliers and pressing the header of connector down to even
position.
Mortise Mount Installation
Surface Mount Model Dimensions
Surface Mount Installation
Glass Mount Model Dimensions
Glass Mount Installation
Installation Instructions
- Confirm the installation location and clean the surface of the glasses.
- Take off the sticker on the back side of the spacer and attach the space to the glass. Add more spacers if needed per glass thickness. Use silicone sealant or other adhesives to secure the bracket firmly.
- Tighten the set screws with an Allen wrench, secure the electric lock to the glass bracket, and then install the cover.
Caution:
- It is recommended to attach the spacers to the interior/secured side of the door.
- Tighten the set screws firmly but do not overtighten to cause damage to the glass.
- The glass thickness should be 10~13 mm. The bracket can be adjusted to properly align the position of strike plate and lock body depending on the door gap ranging from 6 to 10 mm.