Dimension
Specifications
Transmitter on Frame Side
Input Power| 27.6 VDC
Current Draw| 1A/27.6VDC
*Requires 1.5 A power when energized
Lock Status Output| Relay (Dry contacts: N.O./N.C./Com.) Rating: 1A/ 30VDC
Door Status Output
| Reed Switch
(Dry contacts: N.O./N.C./Com.) Rating: 0.1A/ 20VDC
Receiver on Door Side
Output Power| 12/24 VDC
Current Draw
| 800mA/12VDC
400mA/24VDC
Lock Status Input| Dry contacts: N.O./Com.
Infrared Sensing| Transmitter Receiver
Door Opening Time
| 15 / 30 seconds
*For fail-secure locks only
Maximum Door Gap| 3/16” (4~5mm)
Maximum Tolerance with 3/16″ (4~5mm) Door Gap| Horizontal alignment :
1/16″ (1mm) Vertical alignment : 1/16″ (1mm)
IR Sensing: 1/16” (1mm)
Operating Temperature| 32° to +120.2°F ( 0° to +49°C )
Humidity| 0 to 85% Non-condensing
Installation &Wiring
Included in Package
- Door Side Unit
- Wood Screws
- Frame Side Unit
- Metal Screws
- Door Side Template
- Mounting Tabs
- Frame Side Template
- Washers
Note: For optimal performance, it is recommended to minimize the door gap and use the supplied templates. The WLP-100 allows for some horizontal and vertical misalignment. Tolerance for minor misalignment will increase as the door gap decreases.
Installation Steps
-
Door & Frame Inspection
After checking the door and frame conditions, apply the templates at the appropriate location. The WLP-100 can be installed on the latch side, hinge side, or top of the door.
1a. Apply the door-side template.
1b. Apply the frame side template. Make sure to align the horizontal and vertical centerlines. -
Metal Door Installation
2a. Center punch the screw locations for mounting tabs and counter-sink for the M5 screw. 2b. Cut out the main body on the door.2c. Check if the WLP-100 fits well in the cutout and use the file if necessary. 2d. Install mounting tabs using M5 screws. -
Wood Door Installation
3a. Drill two 1″ (25mm) diameter holes, 1/8″ (3mm) in depth as shown on the template. 3b. Drill and cut the WLP-100 main body to a minimum depth of 1-9/16” (40mm), and a diameter of 1″ (25mm) on the door side. 3c. Use the chisel to straighten the sides. 3d. Check if the WLP-100 fits well in the cutout and use the file if necessary. 3e. For the door side unit, drill a wiring channel to the electrified device to be powered. -
Selecting the Lock Output Voltage
Use the jumper on the back of the door-side unit to select the appropriate lock voltage. -
Frame Installation
For the frame side unit, repeat steps 2 or 3 to install on a metal or wood frame.
Wiring Instructions
Please refer to the wiring diagrams on page 5, 6.
WLP-100 | Pigtail | Wire Color | Function |
---|---|---|---|
The frame (Transmitter) | Input Power | Red (+) | 27.6VDC / 1.5Amp |
Black (-) | Ground | ||
Reed Switch | Red | N.C. | |
Black | COM. | ||
White | N.O. |
Relay Output (Lock Status)
| Yellow| N.C.
Green| COM.
Blue| N.O.
Receiver Unit
12VDC
24VDC
OUTPUT
| Door Leaf (Receiver)|
Lock Status Input
| Blue| N.O.
Green| COM.
Lock Power Output| Red (+)| 12 or 24VDC
(select through jumper setting)
Black (-)
WLP-100 Wiring Diagram (1)
WLP-100 Wiring Diagram (2)
- Copyright © All Rights Reserved. P-MU-WLP-100 Published: 2022.05.13
Documents / Resources
|
GIANNI WLP-100 Wireless Power
Transfer
[pdf] Instruction Manual
WLP-100 Wireless Power Transfer, WLP-100, Wireless Power Transfer, Power
Transfer, Transfer
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>