General Information
Operation Manual Information
- This operation manual allows you to work safely with the Wöhler Viper Vent. Please keep this manual for your information.
- The Wöhler Viper Vent Set is to be used by professionally trained personnel exclusively for the purpose for which it was designed.
- Liability is void for any damages caused by not following this manual.
Notes
-
WARNING!
Not following this warning can cause injury or death. -
ATTENTION!
Not following this note can cause permanent damage to the device. -
NOTE!
Useful information
Intended Use
The Rotary Viper Vent is suitable for cleaning ventilation lines, regulated
dwelling VAC systems, air ducts up to Ø 250 mm, exhaust gas lines from 80-150
mm, connecting flue pipes and flue outlet pipes of tiled stoves. A mains
powered or re-chargeable-battery powered drill is used to rotate the threaded
cleaning attachments (brush heads and impact brushes). The scope of supply
does not include a mains powered or rechargeable-battery powered drill.
Scope of supply
Meter | Basic equipment |
---|---|
Wöhler Rotary Viper Ventilation M 10 | Rotary Viper Vent |
Brush Head Perlon (Ø 18 cm)
Depending on set con- figuration: Optional cleaning heads
Transport and storage
ATTENTION!
The device may be damaged if improperly trans- ported or stored!
- Observe the smallest bending radius of 12 cm when storing and transporting.
- Ensure the rotary viper is not exposed to direct sunlight over a very long period of time when being stored, as this can damage the protective sheath.
Manufacturer
- Wöhler Technik GmbH
- Wöhler-Platz 1
- 33181 Bad Wünnenberg
- Tel.: +49 2953 73-100
- Fax: +49 2953 73-96100
- Email: info@woehler.com
Specifications
Rotary viper
Length| 1.5 m or 3 m or 5 m or 10 m or 15 m
Max. torque| Clockwise rotation: 3 Nm
Anticlockwise rotation:
1.5 Nm
Failure moment| Clockwise rotation: 9 Nm
Anticlockwise rotation:
4.5 Nm
Max. speed| Clockwise rotation: 1300 rpm
Anticlockwise rotation:
650 rpm
Smallest bending ra- dius| 120 mm
Coat| Material: PA
12 mm Ø
Connection for cleaning attachments| M10 thread
Operating temperature| 0 – +80°C
Overview
Legend
- Rotary viper
- Power drill connector
- Cleaning attachment, here Perlon brush head
Preparing for use
Fitting the cleaning attachment
ATTENTION!
Use only brush head or impact brush attachments made of Perlon.
- Screw the lock nut (3) on to the cleaning attachment.
- Screw the cleaning attachment (brush head or impact brush) (1) into the coupling (2).
- Use a wrench to hold the lock nut in position and tighten the cleaning attachment using a second wrench. Fig. 4: Cleaning attachment (1) coupling with female thread M10 (2) and locknut (3)
NOTE!
It is particularly important to tighten the cleaning attachment using two wrenches, because this will ensure the cleaning attachment will not work loose in use.
Connecting the power drill
WARNING!
If the brush suddenly becomes blocked, there is a risk the power drill will be
ripped violently out of your hands. Consequently, we recommend you use a power
drill with a torque clutch.
- Insert the power drill connector of the rotary viper into the drill chuck. Observe the instructions in the operating manual belonging to the power drill and obey the safety instructions in particular.
Using the rotary viper
-
Before using, unroll the rotary viper fully.
-
Power on the power drill to make the cleaning attachments rotate.
-
ATTENTION!
- The rotary viper must only rotate clockwise. If it rotates anticlockwise, there is a risk the attached brush will work loose.
- Clockwise direction of rotation: Max. 1 300 rpm with cleaning attachment
- Anticlockwise direction of rotation: Max. 650 rpm with brush head
-
ATTENTION!
Friction will cause the temperature of the sheath to rise if the rotary viper is used for longer periods of time. Ensure the specified operating temperature of 80°C is not exceeded, otherwise the sheath of the rotary viper will be damaged. -
ATTENTION!
Do not tread on the rotary viper when it is in use. Do not allow it to strike against the floor. That could damage the sheath of the rotary viper and degrade its anti-friction properties. -
ATTENTION!
Avoid overloading: If the cleaning attachment can no longer rotate in a pipe, stop the rotary viper rotating and push it through the pipe to be cleaned without any rotation. Rotate the cleaning attachment of the rotary viper first when you are pulling it back.
Maintenance
- The Wöhler rotary viper requires very little maintenance. The bearings in the end pieces are self-lubricating. The core is sufficiently greased with high-quality graphite lubricant.
- After it has been in use for a long time it is possible that the grease in the core will need to be replenished. This will become noticeable by the protective PA sheath becoming unusually warm. It should be returned to the factory for the grease to be replenished.
Warranty and Service
Warranty
- Each Wöhler Rotary Viper Vent will be tested in all functions and will leave our factory only after ex-tensive quality control testing.
- If used properly, the warranty period for the Wöh-ler Rotary Viper Vent will be twelve month from the date of sale.
- Not covered by the warranty are cleaning attach-ments (brush head made of Perlon or threaded brush), because they are consumables.
- This warranty does not cover the freight and pack-ing costs when the device is sent to the factory for repair.
- Service by non authorized personnel or making modifications to the analyzer voids any warranty.
Service
- Wöhler has built our reputation on excellence in customer service. Therefore, of course, we are readily available to assist you after the warranty period ends.
- Send us the device and we will repair it and return it to you with our package service.
- Immediate help is provided by our technical staff over the telephone.
Accessories
- Brush Head, Perlon 12,5 cm Ø, M 10: Order no. 1458
- Brush Head, Perlon 18 cm Ø, M 10: Order no. 1466
- Brush Head, Perlon 25 cm Ø, M 10: Order no. 7102
- Threaded Brush, Perlon, 30 cm Ø, M 10: Order no. 18730
- Wöhler Soot Door Sealing: Order no. 3380
CONTACT
Points of sale and service
- Germany
- Wöhler Technik GmbH
- Wöhler-Platz 1
- 33181 Bad Wünnenberg
- Tel.: +49 2953 73-100
- Fax: +49 2953 73-96100
- info@woehler.de
- www.woehler.de
- Wöhler West
- Steiger-Stein-Str. 5
- 44805 Bochum
- Tel.: +49 234 516993-0
- Fax: +49 234 516993-99
- west@woehler.de
- Wöhler Süd
- Gneisenaustr.12
- 80992 München
- Tel.: +49 89 1589223-0
- Fax: +49 89 1589223-99
- sued@woehler.de
- USA
- Wohler USA Inc.
- 208 S Main Street
- Middleton, MA 01949
- Tel.: +1 978 750 9876
- www.wohlerusa.com
- Italy
- Wöhler Italia srl
- Via Coraine 21
- 37010 Costermano VR
- Tel. +39 045 6200080
- Fax. +39 045 6201508
- info@woehler.it
- www.woehler.it
- Austria
- Wöhler GmbH
- Heinrich-Schneidmadl-Str. 15
- 3100 St. Pölten
- Tel.: +43 2742 90855-11
- Fax: +43 2742 90855-22
- info@woehler.de
- Czech Republic
- Wöhler Bohemia s.r.o.
- Za Naspern 1993
- 393 01 Pelhrimov
- Tel.: +420 565 323 076
- Fax : +420 565 323 078
- info@woehler.cz
- France
- Wöhler France SARL
- 17 impasse de Grousset
- 31590 LAVALETTE
- T e l.: +33 5 61 52 40 39
- F ax: +33 5 62 27 11 31
- info@woehler.fr
- www.woehler.fr
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>