mpsenergy EDS-C1 Mpsmain User Manual
- June 9, 2024
- mpsenergy
Table of Contents
mpsenergy EDS-C1 Mpsmain
- Website: https://www.mpsenergy.com.tw/
- Visit us:
Specification
- Input Voltage 12 / 24 / 36 V
- Communication UART / CAN for controller
- Interface BLE for app
- Display OLED
- Key Power / + / button
- Operating Temperature 20°C ~ 60°C
- IP IP 65
- Certifications ISO 13849 1 2015 certification
Operation
How to power on HMI
Long press “Power key” for 3 seconds to power on the HMI. After powering up
the HMI, you will see the startup screen as the following figure.
How to power off
During HMI at power on state, you can long press “power key” for 3 seconds to
power off the HMI.
Main Screen information
In the main screen, you can check the current status, for example, the current
assist mode, current battery capacity, current speed, etc. as the following
figure.
Battery Indication
You can check the battery icon to know the current battery capacity as the
following figure.
Assist levels
- Short press UP / D OWN key to switch the assist level . Top level is 3, 0 for
Walk mode
Keep pressing the DOWN key to enter the Walk mode . The speed limit for
Walk mode is 6km/hRelease the D OWN key to return back to the assist mode
.
Headlight ON/OFF
Long press the UP key for 1 second. Once the headlight icon is displayed on
the screen, the headlight is ON. To turn OFF, press the UP key for 1 second
.
Total Distance (ODO)
Short press the Power key to switch the mileage mode , the Total Distance
(ODO) screen is as following figure.
- In this screen, user can long press the DOWN key for 2 seconds to reset the ODO value to 0.
Range ( Remain Distance
Short press the Power key to switch the mileage mode , the Range ( Remain
Distance screen is as following figure .
Bike status monitoring
These status icon show on screen can assist user to check the status of the E
bike.
For status like:
- Speed is over Speed Limit
- Brake status
- Low battery voltage
- Temperature is above the limited value on the controller
If any of these statuses happens , the control ler shall stop the motor output immediately.
Controller status monitoring
These status icon show on screen can assist user to check the status of the controller.
If any of below status happens:
- OC Over Current
- OT ( Over Temperature
- OV Over Voltage
- UV Under Voltage
- SW Error
The controller shall stop the motor output immediately.
Connection problem
If there is any connection problem betw een the controller and the HMI, a
timeout logo will be displayed . P lease try to switch the HMI and battery off
first and check if the cables are well connected and then switch on HMI again.
The UART grounded logo sometimes will be showed before timeou t happened, it indicated the problem is caused by UART communication error . Unplug and plug in the connector of HMI again may solve the issue. Please m ake sure all power is turned OFF before the operation.
BLE connection
When the APP establishes a BLE connection with the HMI, on HMI it shall
display the BLE pin code screen as following figure.
- In this screen, user can long press the UP and DOWN key s simultaneously for 2 seconds to reset the BLE pin code to the default code (0000).
After user input the BLE pin code on the APP and the pin code is correct, the HMI shall return to the main screen. It will also display a BLE ic on to indicate that the BLE connection is established.