W HLER VE HD Video Endoscope Probe 180 Degree Panable Instruction Manual
- June 1, 2024
- W HLER
Table of Contents
W HLER VE HD Video Endoscope Probe 180 Degree Panable
General
Intended Use
The HD video endoscope probe 180°panable can only be used together with the
endoscopes Wöhler VE 220, VE 320, VE 400 or VE 500.
Adress Wöhler Technik GmbH
- Wöhler-Platz 1
- 33181 Bad Wünnenberg
- Tel.: +49 2953 73-100
- E-Mail: info@woehler.de
Important Notes
Warning!
Do not use the probe and endoscope in an explosive environment.
ATTENTION!
The probe may only be connected to the Wöhler VE 220, 320, 400 and 500
endoscopes.
ACHTUNG!
Always connect the probe to the endoscope using the 1.5 m connection cable.
This is included in the scope of delivery of the endoscope. Otherwise, the
connection socket of the probe may be damaged due to the mechanical load..
ATTENTION!
Make sure never to twist or kink the probe cable.
ATTENTION!
Never turn the rotary knob on the probe handle more than a quarter turn in any
direction.
ATTENTION!
Stand the probe tip upright before pulling the probe out of the inspection
port. The Wöhler logo on the rotary knob is then exactly parallel to the probe
handle.
ATTENTION!
Dry the probe after contact with liquid and make sure that it is stored in a
dry place.
Technical Data
Description/Details
- Probe diameter 6,2 mm
- Probe length 150 cm
- Focal Distance 20 – 100 mm
- Field of view (FoV) 100°
- IP class IP 67 (Temporary immersion up to a maximum of 30 minutes)
- Lightning Source 6 LEDs
Design
Connecting the probe
NOTE!
Connect the camera probe before switching on the Wöhler VE. If you connect the
probe when the device is switched on, you will need to restart the Wöhler VE.
- To connect the probe to the monitor, insert the probe into the female connector ensuring the notch on the male connector is precisely aligned with the red dot on the female connector.
- Then tighten the gland nut finger-tight.
ACHTUNG!
Always connect the probe to the endoscope using the 1.5 m connection cable.
This is included in the scope of delivery of the endoscope. Otherwise, the
connection socket of the probe may be damaged due to the mechanical load.
Operation
- Switch on the Wöhler VE and operate it as described in the Wöhler VE operating instructions.
- To swivel the probe tip 180° to the left or right, turn the rotary knob to the left or right. The probe tip is 0° straight ahead when the Wöhler logo on the rotary knob is parallel to the handle.
ACHTUNG!
Never should the rotary knob be turned more than a quarter turn in any
direction.
Specifications
- Probe diameter: N/A
- Probe length : N/A
- Focal Distance: N/A
- Field of view (FoV): N/A
- IP class: N/A
- Lightning Source: 6 LEDs
FAQ
Q: Can I use the probe and endoscope in an explosive environment?
A: No, it is advised not to use the probe and endoscope in such
environments for safety reasons.
Q: What should I do if the probe cable gets twisted or kinked?
A: Carefully straighten out the cable to avoid any damage to the device during
usage.
Q: How should I store the product when not in use?
A: Ensure the probe is dry and store it in a dry place to prevent any
damage due to moisture.