ABESTORM Hurricane 85P Restoration and Drying Equipment User Manual
- June 9, 2024
- ABESTORM
Table of Contents
- ABESTORM Hurricane 85P Restoration and Drying Equipment
- Safety Instructions
- Identification
- Electrical Supply
- How the Dehumidifier Works
- Guidelines
- Parts Diagram
- LCD Display Instructions
- Maintenance Instructions
- Troubleshooting
- Dehumidifier Storage
- Limited Warranty
- Limited Warranty Exclusions
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ABESTORM Hurricane 85P Restoration and Drying Equipment
Safety Instructions
- Don’t adjust or alter the unit in any way.
- The use of unauthorized parts will void your warranty. Contact your approved distributor for assistance.
- Always unplug the unit prior to removing the cover.
- Inspect the power cord prior to use and do not use if it is damaged.
- The unit should only be used with a 115V/60Hz circuit protected by a GFCI outlet.
Identification
Prior to installation of the unit, write down the serial number and date of purchase. You will need this information if you need assistance in the future. The data label on the side of your unit has the necessary information.
- Serial Number: __
- Date of Purchase: __
For additional questions concerning your dehumidifier:
- Contact your installing contractor
- Contact Abestorm Solutions: sales@abestorm.com
Electrical Supply
- Power Supply: 115V/60Hz
- Outlet Requirement : 3-Prong, GFCI
- Сircuit protector: 15 Amp
WARNING
Using a 220V outlet may cause serious injury from electric shock.
To reduce risk of injury:
- Always disconnect machine from electrical power before servicing
- Only plug unit into a grounded electrical circuit
- Do not use an extension cord
- Do not use a plug adapted
How the Dehumidifier Works
The dehumidifier utilizes its integral humidistat to monitor the conditioned
space.
Once conditions are outside the desired setpoint, the compressor energizes and
air is drawn across an evaporator coil.
The evaporator coil is cooler than the dew point of the air so the water vapor
will turns into liquid condensation.
The air is then reheated through the condenser coil and distributed back into
the room.
Guidelines
Operation Notes
- Always make sure that the unit is operated, transported, and stored on a stable surface.
- For maximum efficiency, operate the unit with all windows and doors closed.
- Do not place the unit anywhere that may block the inlet or outlet airflow.
Drain Hose Notes
- The Hurricane 125P is equipped with an external drain line connection, making it easy to plug in.
- The drain line can be directed outside or into any sink, drain, etc.
- For more effective draining, uncoil the entire hose before using.
- Never place the end of the hose higher than 15 feet.
- Always ensure that the drain hose is not blocked prior to use.
Transportation Notes
- Always secure the dehumidifier during transportation.
- If the unit is transported vertically, return it to a normal horizontal position, and let sit for 30 minutes prior to use.
Parts Diagram
LCD Display Instructions
-
When the machine is powered on but not working: (after power on, the buzzer makes a sound) The machine displays when it is not working. (Power off state but have electricity).
-
Main interface display of dehumidification state:
The following information is displayed when the machine is working:-
000 JOB HRS:
Refers to the working time, which is defined as the time from starting up to shutting down, including the defrost time during the period, and the standby time after the humidity. The submenu has a reset function. If not, the working time shall be accumulated.
Total time 9999 hours, the largest cumulative to the largest automatically reset after restart, and display units for hours. (round off). -
000 LIFE HRS:
Refers to the total working lime, i.e. the total working lime (hours), which is in hours. (press the mode key+ select the confirmation key, and the total working time will be cleaned after 3 seconds. -
IN/OUT 00°F 00% 00 gr/ lb:
Indicates the temperature, humidity and moisture content of the air inlet and outlet. {GPP- grain par pound (grAb)}. -
Set 00%:
Indicates set humidity. -
If the main interface does not operate for 10 minutes, the screen will go out. Press any key to wake up.
-
Other icons light up or flicker when opened.
The total working time is the accumulation of each working time (hours) in hours. (Press the mode key+ select to confirmation key, and the total working time will be cleaned after 3 seconds.
-
-
Dehumidification status submenu interface display
-
11lndicates”: Do I need to clear out this time?11 ,press “>”if you need to clear. When the operation is completed, the working time of the main
interface and the working time of this interface will be reset and started to be instant again. After accumulation (9999), clean up and round. -
“Coll Temp 000″C “: Used to display the current temperature of the coil. Whan ii is below zero, the”-” symbol is displayed in front. “-” is not required on zero.
-
WI-Fl hotspot: Factory selling is “OFF”, press > to enable wifi hotspot and switch ON/OFF. The device can transmit data and receive APP commands. The icon flickers when connected on the main interface. After successful connection, the icon displays normally.
( Note: This model does not come with WiFi function and is only suitable for application-controlled dehumidifiers.)
-
The power down time is adjusted according to”>” and the power down lime increases from 3 to 20 minutes (3-5-10-15-20), which is the so-called stop time of the fan after shutdown, in order to better drain the water. Factory set for 3 minutes. (the other state of the fan is still 15 seconds.)
-
The screen displays when you press shut down:
Indicates: the fan is closed after a few minutes, and the standby page UNIT OFF is displayed after the fan is closed. -
“Temp Units °F/’C”: Used for temperature scale switching. Press the”>” button to switch °Frc, after switch symbol of corresponding parts is also changing.
-
“MOISTURE CONTENT UNITS”: It is used to switch the unit of GPP value with moisture content. Press > to switch the LB or , after switch symbol of corresponding parts is also changing.
-
“Humidistat Setpoint 00%”: Used for setting dehumidification mode humidity. Press “>” to set the humidity. The adjustment range of humidity setting is between 25 and 80%.
Each key rises or falls 5%, which can be recycled.
When the setting is completed, do not operate for 5 seconds and begin to take effect. (Otherwise, the compressor will be shut down immediately after it is below ambient humidity at the time of setting.) Humidity below 25 percent’s “CO” mode recyclable. The main interface displays the set parameters . -
Main interface frosting status display:
The machine will display this after defrost when runningWhan the machine is running normally, “Defrost SHUTDOWN IN 06:00” will occurs in the interface after defrosting. It’s defrost countdown use seconds as units. This screen displays only 3 seconds. Displays the previous interface and status after restoration. If it is the home screen, the frost icon will flash.
When the user is operating in the submenu, the machine is in the frosting state. At this point, the frosting interface displays 3 seconds, and returns to the submenu program in the background countdown. When the user returns to the main interface without any operation, the frosting state is displayed in the main interface in the way of icon flicker. -
Compressor on waiting interface display
Compressor protection time not shown: “Compressor ready IN 03:00” indicates :
That the interface will be displayed when the compression is in a protected state. (including power-on and shutdown, the humidity rises immediately after the arrival of L0 HI, and the shutdown resumes immediately after the emergence of L0 HI). Displays the countdown in seconds. If the above situation does not occur within 3 minutes, it is not shown. -
Water Pump working interface display
Compressor protection time not shown:“Pump working countdown11 : indicates: No matter in which working state and interface, as long as the pump works, this interface appears and counts down to 28 seconds. However, the interface only displays the previous working status and interface after 3 seconds. For example, after 3 seconds, there is a drainage icon on the main interface and it will flash until the drainage is finished. -
interface display in case of failure
Machine running time fault display: Make fault judgment and lake corresponding actions after starting up. Regardless of the state, the fault is executed first and the fault code is displayed on the interface. If there is a fault in the sub-menu operation, immediately return to this interface display fault (including defrosting state). (the fault is judged when the pump works, and the fault is displayed as usual, but the pump needs to complete the water pumping this lime). Multiple faults can be displayed at the same time.
Description of fault display:
-
Humidity sensor fault: when the humidity sensor unit fault or signal can not be transmitted, the fault is judged to be E1. The machine is out of operation (power on again after troubleshooting). Pump button can operate.
-
Ambient temperature T,s;:;2: When the sensor continuously detects the ambient temperature of inlet air T=2 degrees for 600 seconds, the fault is judged to be LO and the whole machine is stopped. Other values, corresponding to the temperature region operation. (recoverable). At this time, the interface cannot
be operated. The pump button can be operated. -
Ambient temperature T;,,45: When the sensor continuously detects the inlet air environment temperature T=45 degrees for 15 seconds, the fault is judged to be HI and the whole machine is stopped. Other values, corresponding to the temperature region operation. (recoverable). At this time, the interface
cannot be operated. The pump button can be operated.
Maintenance Instructions
Before Use
- Check the power cord for signs of damage such as fraying. Replace the cord before use if there is any damage.
- Check the filter for signs of dirt or obstructions. Clean or replace the filter as necessary.
- Check the coils for signs of buildup. Clean if needed.
Cleaning the Machine Body
Use a soft, damp cloth to clean the exterior of the unit. Do not use any soap or solvents.
Filter Maintenance
- Unplug the unit.
- Slide out the filter.
- Check the filter for dirt and buildup.
- For a Pre-Filter or MERV-8:
- Clean the filter mesh by vacuuming it or washing with warm water (no soap or cleaners).Gently shake the filter dry, then reinsert it.
Removing the Housing
- Remove the screws on the housing.
- Remove the screws on the air inlet grill and air outlet grill.
Coil Maintenance
- Once per year, clean the coils with an approved coil cleaner.
- Coil cleaner should be a self-rinsing, foaming cleaner such as WEB® Coil Cleaner.
Pump Maintenance
Pump Access:
Remove the screws on the housing, then lift off. Unplug the pump drain line,
then remove the screws holding the pump in place.
Cleaning the Pump Reservoir:
Once the screws are removed, lift off the top of the pump and set aside. Use a
paper towel to wipe out the base of the pump.
Troubleshooting
Symptom | Cause | Solution |
---|---|---|
Display is Blank | Poor Connection | Verify that both ends of the power cord are |
plugged in.
Power Outage| Reset power.
NO Air flow| Filter is Dirty| Clean the filter.
Air Inlet or Outlet is Blocked| Clear the blockage.
Error Code: El| Humidity Sensor or Communication Error| Check to ensure that
the sensor wire is connected at both ends. if no issues a re visible, the
sensor may be faulty.
Error Code: E4| Problem with Pump| Verify that the pump is properly installed
and functioning. If so, unplug the unit for two minutes, then restart.
Error Code: LO| Room Temperature is below
33.8° F
| Increase the room temperate Lie so it is within operating range (above
33.8°F). If error still displays, check sensor.
Error Code: HI| Room Temperature is above 110 ° F| Decrease the room temperate
so it is within operating range (below 11o ° F ). If error still
displays, check the sensor.
ES Error Code| Refrigerant Leak| Contact your installer for assistance.
Dehumidifier Storage
If the unit will be stored for an extended period of time, complete the following steps:
- Tum off the unit and allow it to to dry.
- Clean out the pump reservoir.
- Wrap and secure the power cord.
- Cover filter mesh.
- Store in clean, dry space.
Abestorm Solutions Inc. DEHUMIDIFIERS
Limited Warranty
This limited warranty starts from the date of purchase. Abe storm Solutions Inc. warrants to the original purchaser that this Abe storm product is free from manufacturing defects in material or workmanship for the limited warranty period of:
Six (6) Month parts and labor. This includes the shipments charges for
replacement parts or unit.
One (1) year parts and labor. This does not include the shipment charge to
send the defective product back to be repaired or replaced.
Three (3) years parts and labor on Refrigeration System ON LY (Compressor,
Condenser, and evaporator). Transportation cost, not included
Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and
evaporator). Transportation cost, not included
This limited warranty is valid only on products purchased from the manufacturer or Abestorm authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Abestorm Solutions Inc will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact Abestorm at
(888)276-9833 or sales@abestorm.com.
A proof of purchase or order number is required to receive warranty service.
During the applicable warranty period, a product will be repaired or replaced
at the sole option of Abestorm.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:
- Damage occurs in uses for which this product was not intended for.
- Damage caused by unauthorized modification or alteration of the product.
- Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
- Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
- Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
- Damage caused by failure to perform proper maintenance of the product.
The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>