SAFETY INSTRUCTIONS
Read these instructions before use and save them for future reference.
- For indoor use only.
- Disconnect the power supply before installation.
- Check that the rated voltage corresponds to the mains supply voltage.
- Do not connect the product to the mains while it is still in the pack.
- Check that all electrical cables comply with the applicable regulations and that they are connected in accordance with the instructions. Never attempt to replace damaged electrical cables yourself.
- Never overload the mains. This can result in fire or a risk of electric shock.
- Keep out of the reach of children.
- Do not store the product in a very cold/ hot place to avoid damaging the electronics.
- The electronics in the product are sensitive to knocks and blows. Avoid dropping it.
- The light source is not replaceable. If the light source stops working the product must be discarded.
- The product is not dimmable.
- Take care to avoid damaging anyconcealed wiring and pipes during installation.
- Be careful not to damage the insulation on the wires during installation. Make sure that the wires do not come into contact with sharp edges. Damaged insulation can result in a risk of electric shock.
- Do not look directly into the light source.
- The product can be installed inenvironments where an accumulation of conductive dust may be expected. In these environments, the electrical connection must comply with EN 60364-4-42
WARNING
New installations and extensions to existing systems must always be carried out by an authorised electrician. If you have the necessary experience and knowledge (otherwise contact an electrician), you can replace power switches and wall sockets, fit plugs, extension cords and light sockets. Incorrect installation can result in fatal injury and the risk of fire.
SYMBOLS
| ****
Read the instructions.
---|---
| Safety class II
| Approved in accordance with the relevant directives.
****| Recycle discarded product in accordance with local regulations.
TECHNICAL DATA
Voltage | 230 V ~ 50 Hz |
---|---|
Output | 13.5 W |
Luminous flux | 1500 lm 360° |
Colour temperature | 6500 K |
Life span | 15,000 h |
Colour rendering index | 80 |
Energy class (A – G) | E |
Dimensions | L1000 x W62 x H36 mm |
MOUNTING
- Insert the expansion plugs for M4 screws into the ceiling or wall.
- Using M4 screws, secure the bracket to the ceiling or wall.
- Connect the wires to the product’s terminal block.
- Screw the product to the bracket. FIG. 1-9
MAINTENANCE
Switch off the power supply before cleaning and/or maintenance
PRODUCT INFORMATION SHEET
Supplier’s name or trademark: | ANSLUT |
---|---|
Supplier’s address (a): | Jula AB, Box 363, 532 24 SKARA |
Model identifier: | 023743 |
Type of light source: | |
Lighting technology used: | LED |
Light source cap-type
(or other electric interface):
| Terminal connector| |
Light source connected to mains supply or light source not connected to mains
supply:| MLS| Connected light source (CLS):| no
Colour -tunable light source:| no| Envelope:| no
High luminance light source:| no| |
Anti-glare shield:| no| Dimmable:| no
Product parameters
Parameter| Value| Parameter| Value
General product parameters:
Energy consumption in on-mode (kWh/1000 h), rounded up to the nearest
integer.| 14| Energy efficiency class| E
Useful luminous flux (Φuse), indicating if it refers to the flux in a sphere
(360˚), in a wide cone (120˚) or in a narrow cone (90˚).| ****
1 500 in Sphere (360°)
| Correlated colour temperature, rounded to the nearest 100 K, or the range of
correlated colour temperatures, rounded to the nearest 100 K, that can be
set.| 6 500
On-mode power (Pon), expressed in W.| 13,5| Standby power (Psb), expressed in
W and rounded to the second decimal.| –
Networked standby power (Pnet) for CLS, expressed in W and rounded to the
second decimal.| –| Colour rendering index, rounded to the nearest integer, or
the range of CRI-values that can be set.| 80
Outer dimensions without separate control gear, lighting control parts and
non-lighting control parts, if any (millimetre).| Height| 62| Spectral power
distribution in the range 250 nm to 800 nm, at full-load.| [See image in last
page]
Width| 1 000
Depth| 36
Claim of equivalent power (c)| –| If yes, equivalent power (W)| –
| | Chromaticity coordinates (x and y)| 0,313
0,337
Parameters for LED and OLED light sources:
R9 colour rendering index value| 0| Survival factor| 0,90
The lumen maintenance factor| 0,93| |
Parameters for LED and OLED mains light sources:
Displacement factor (cos φ1)| 0,70| Colour consistency in mcadam ellipses| 6
Claims that an LED light source replaces a fluorescent light source without
integrated ballast of a particular wattage.| -(b)| If yes then replacement
claim (W)| –
Flicker metric (Pst LM)| 1,0| Stroboscopic effect metric (SVM)| 0,4