RAB CRVFAD-xxR-xx-9CCT-UNV-BN Flush Mount Instructions

June 9, 2024
RAB

RAB CRVFAD-xxR-xx-9CCT-UNV-BN Flush Mount

RAB-CRVFAD-xxR-xx-9CCT-UNV-BN-Flush-Mount-product

IMPORTANT
READ CAREFULLY BEFORE INSTALLING THE FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixture must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT ANDTHE HAZARDS INVOLVED.

TO PREVENT ELECTRICAL SHOCK, POWER SHOULD BE TURNED OFF AT THE FUSE BOX BEFORE INSTALLATION.

SAFETY WARNINGS

Read all product labels and directions

  • WARNING
    Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. local codes. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

  • WARNING – To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects.

  • INSTALLATION SHOULD ONLY BE PERFORMED AFTER THE POWER TO THE FIXTURE HAS BEEN DISCONNECTED.

  • These instructions shall be included on an information sheet packaged with each unit.

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WHAT’S IN THE BOX

RAB-CRVFAD-xxR-xx-9CCT-UNV-BN-Flush-Mount-fig-1

TOOLS NEEDED

Installation with J-BOX
A screwdriver is needed for the installation

INSTRUCTIONS

RAB Lighting is committed to creating high-quality, affordable, well-designed, and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com.

INSTALLATION WITH J-BOX
  1. Make sure the POWER IS TURNED OFF at the source to the J-box in which you are installing the product.
  2. Loosen screws counterclockwise and disassemble the surface mount cover. (Fig.1)RAB-CRVFAD-xxR-xx-9CCT-UNV-BN-Flush-Mount-fig-2
  3. Select desired CCT. (Fig.2)RAB-CRVFAD-xxR-xx-9CCT-UNV-BN-Flush-Mount-fig-3
  4. Insert screws into J-Box holes, leaving about 15mm of space between the screw heads and J-Box. (Fig.3)
  5. Wire the surface mount, white-white, black-black, green-green/ground, purple-purple, pink-pink. Once wire connec-tions are made, secure each with a wire nut. (Fig.4)
  6. Lift fixture to ceiling and carefully tuck wires into J-Box. Align keyholes on the surface mount with screws, then twist the fixture until the crews engage the narrow end of the keyholes. Tighten screws to secure. (Fig.5)
  7. Reassemble the lamp cover. (Fig.6) Tighten screws clockwise. (Fig.7) Caulk around the mounting surface edge with silicone sealant. (Fig.8).RAB-CRVFAD-xxR-xx-9CCT-UNV-BN-Flush-Mount-fig-7

Note:
These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation, or maintenance.

RAB WARRANTY

RABS warranty is subject to all terms and conditions found at rablighting.com/warranty.

Easy Answers

rablighting.com
Visit our website for product info

Tech Help Line

  • Call our experts: 888 722-1000