REHAU 13280001001 Thermostat Installation Guide

June 9, 2024
REHAU

REHAU 13280001001 Thermostat

REHAU 13280001001 Thermostat

Safety Instructions and Product Conformity

Risk of life through electrical shock! The electrical installation must follow the applicable national standards and guidelines as well as any specific requirements of your local energy supplier. These instructions are intended for use by a qualified person who is holding an official certificate in one of the following professions:

electrician or electronics engineer

Always read the instructions prior to commencing the installation. Connection to the final power supply must only be carried out after the installation is complete.Hereby, REHAU Industries SE & Co. KG declares that the radio equipment type Room Unit (mat. no. see B) is in compliance with EU directive 2014/53/EU and UK regulation UK: 2017 No. 1206. The full text of the EU and UK declaration of conformity is available at the following internet address: www.rehau.com/neasmart2

System Overview

REHAU 13280001001 Thermostat 1

Installation

REHAU 13280001001 Thermostat 3

  • Bus (ZOBUS)
  • Wireless / Radio
  • Remote Sensor

REHAU 13280001001 Thermostat 2

Assignment of a room controller to a room zone

Assignment of a room controller to several room zones

REHAU 13280001001 Thermostat 6

Delete Pairing Sequence

REHAU 13280001001 Thermostat 7

Set up external sensor

REHAU 13280001001 Thermostat 8

Parameters

  • Not connected
  • Floor temperature probe for minimum and maximum value monitoring (minimum value valid for cooling, maximum value for heating
  • Floor temperature probe for minimum and maximum value monitoring (minimum value valid for cooling and heating, maximum value for heating)
  • External floor temperature probe (floor temperature control only
  • External room temperature probe (room temperature control by mean value of external and internal probe
  • Dew point monitor (switching contact)
  • Window contact
  • Condensation protection for chilled ceilings (only with humidity room units)
  • External probe for core temperature (TABS)
  • External probe for return temperature (TABS)

Error Messages

  • Room temperature sensor out of sensor range
  • Room temperature sensor broken
  • Room temperature sensor shorted
  • Humidity sensor out of sensor range
  • Humidity sensor broken
  • Humidity sensor shorted
  • Remote temperature sensor out of sensor range
  • Remote temperature sensor broken
  • Remote temperature sensor shorted
  • Connection error Base and R-/U-Module
  • Communication error between base and R-Module
  • Error that is only shown in the NEA SMART 2.0 app

Additional information

This document is protected by copyright. All rights based on this are reserved. No part of this publication may be translated, reproduced or transmitted in any form or by any similar means, electronic or mechanical, photocopying, recording or otherwise, or stored in a data retrieval system.Our verbal and written advice with regard to usage is based on years of experience and standardised assumptions and is provided to the best of our knowledge. The intended use of REHAU products is described comprehensively in the technical product information. The latest version can be viewed at www.rehau.com/TI. We have no control over the application, use or processing of the products. Responsibility for these activities therefore remains entirely with the respective user/processor.Where claims for liability nonetheless arise, they shall be governed exclusively according to our terms and conditions, available at www.rehau.com/conditions, insofar as nothing else has been agreed upon with REHAU in writing. This shall also apply for all warranty claims, with the warranty applying to the consistent quality of our products in accordance with our specifications. Subject to technical changes.