NordCap UKT 2ZG 2ZK Substructure Cooling Table Instruction Manual

June 9, 2024
NordCap

NordCap UKT 2ZG 2ZK Substructure Cooling Table

INSTRUCTIONS FOR USE

This equipment should be operated safely, in accordance with the manufacturer’s original instructions and solely for the designated use. Misuse can cause damage to the equipment and possible injury to the user. Do not store explosive substances, such as aerosol products containing flammable propellant. Do not exceed the limits of maximum permissible load (20 kg per shelf, 40 kg per drawer). If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Time-weighted of equipment noise emissions, in the workplace, does not exceed 70 dB(A).

  • Climatic class 4: 30ºC, 55% RH
  • climatic class 5: 40ºC, 40% RH.

Note from the Manufacturer
Thank you for choosing our refrigerated equipment. We designed it in compliance with the applicable European directives and standards, and developed it to provide the best cold storage conditions for each type of food, with the aim of providing a safe and practical use that will meet your needs and expectations.

SAFETY AND ENERGY EFFICIENCY OPTIMISATION GUIDELINES

  • INSTALLATION
  • STORAGE
  • CLEANING

Rating Plate

The rating plate on our equipment is located inside the equipment, on the left side panel. It includes the main technical data about the equipment and it identifies the MODEL and SERIAL NUMBER, which are vital pieces of information for any queries to the manufacturer.

The European directive on Waste Electrical and Electronic Equipment (WEEE) specifies that, at the end of its life cycle, this equipment and all of its components, subassemblies and consumable materials should be sent separately for treatment for it to be destroyed, recycled or reused. Do not dispose it together with undifferentiated waste.

Receipt
The construction and operation of each piece of equipment is rigorously checked at the factory, as shown in the attached test report. In case damage has occurred in transit, carefully check the general condition of the equipment after unpacking. Then, confirm that the features match the specifications of the purchase order. We remind you that our constant search for technological improvements implies that changes to the equipment described in this manual may be effective without prior notification.

Installation

The equipment installation should be carried out in accordance with building regulations, rules and best practice for accident prevention, fire prevention standards and existing local standards. Technical maintenance, installation and other actions should be carried out by authorised specialised technicians only, using original spare parts. The manufacturer assumes no responsibility resulting from incorrect use of the product or the non compliance of the instructions contained in this manual.

Preparation
To avoid scratches, spots and fingerprints, remove the plastic protective film with gloves without using sharp tools.

Electrical connection
The unit is supplied with a plug in accordance with current standards of practice and with a power cord whose length is sufficient to allow connection to the mains.

  • The mains should be easily accessible and sized for the maximum consumption (see rating plate), and should have an EARTH CABLE. Never use sockets or plugs without earth cable, nor use adapters or extension cords. For direct connections to the network, always install an interrupting device (circuit breaker) in accordance with international standards.

Placement
The equipment must be installed on a flat and sturdy surface, to ensure 4-point support stability, and away from possible sources of heat (like ovens or stoves) and away from direct sunlight. Ensure good air circulation around the equipment, respect the recommended distances and never obstruct the air vents grids: the lack of ventilation seriously affects the operation and can lead to severe damage to the equipment.

Set-up of a topping shelf

  • Assembling the topping shelf on the worktop of a pizza prep table
    For a safe adjustment between the topping shelf and the pizza table, the U-shaped adaptor must be correctly fitted. Please centre the holes of the adaptor with those on the underside of the topping shelf before fastening the blind rivets.

  • Assembling the sneeze guard
    Place the side glasses (1), place the back glass (2) on the back panel fasteners of the topping shelf. Fasten the glasses double and triple linked clip (3) into the holes, place the top glass (4) and screw.

Usage

Indications
Our refrigerated equipment has been designed to store food and food products in general. To reduce energy consumption, optimize the equipment operation, and also improve and extend the shelf life of food, observe the following conditions:

  • Reduce the doors and/or drawers opening frequency and duration;
  • Do not put hot food inside the refrigerated equipment;
  • Ensure that all food is covered or wrapped;
  • Space food to allow for good air flow;
  • Do not exceed load height limit line

Defrosting
The defrosting is carried out automatically with electronic control, which can also be triggered manually. In any case, do not use sharp objects (such as knives, screwdrivers, etc.) to remove a possible excess of ice. In models with automatic defrost water evaporation, water is drained to the condensing unit. In other models, it is drained to a tray underneath the equipment which must be poured regularly. After defrost, keep the doors and/or drawers closed to accelerate the temperature recovery.

Cleaning
To ensure proper hygiene and maintenance, perform regular cleaning as indicated:

  • Switch off the appliance, unplug it and place the plug in a visible place so as it is visible from any point to verify that it remains switched off;
  • Clean the surfaces using a dampened cloth with a mild soap warm water solution; then rinse with a dampened cloth with clean water and finally wipe with a soft, dry cloth;
  • Do not use aggressive cleaning products containing corrosive chemicals or chlorine (such as bleach), or abrasive materials (such as pads) or pressurized water (such as hoses).

Condenser Cleaning
To ensure long life and correct operation of the refrigeration system, clean the condenser coil regularly as indicated:

  • Switch off the appliance, unplug it and place the plug in a visible place so as it is visible from any point to verify that it remains switched off;
  • Unscrew and open the air vents grid; be careful with cable holder, do not stretch the cables;
  • Carefully vacuum (preferably) or brush the condenser coils;
  • Finally, screw back the air vents grid.

Extended Period of Inactivity
Where there is a foreseeable extended period of inactivity, remove all foodstuff from the appliance and clean it as described. In the end, switch it off from the mains and leave the doors open to prevent bad odour.

Use of swivel castors brake

Troubleshooting
If you notice any malfunction, refer to the checklist below to identify the problem and its possible solutions. If the problem still persists, please contact the after-sales service.

Symptom Check
Equipment does not run and the display does not work Make sure the plug is

inserted into the socket
Check for a blown fuse or tripped circuit breaker
Test the power outlet for current
Inspect the electrical cord for damage
Remove any extension cord
Equipment does not run but the display works| Check the temperature setting
Assure that there is enough air flow inside the equipment
Clean the condenser coils
Equipment is not cold enough| Check the temperature setting
Assure that there is enough air flow inside the equipment
Check for airflow restrictions in vents
Clean the condenser coils
Clean the door seals
Check for a clogged drain pipe
Equipment is too cold| Check the temperature setting
Equipment runs continuously| Clean the condenser coils
Clean the door seals
Equipment starts and stops frequently| Clean the condenser coils

Finanzen / Service
28307 Bremen
Thalenhorststraße 15
Tel. +49 421 48557-0
Fax +49 421 488650
bremen@nordcap.de

Vertrieb Ost
12681 Berlin
Wolfener Straße 32/34, Haus K
Tel. +49 30 936684-0
Fax +49 30 936684-44
berlin@nordcap.de

Vertrieb West
40699 Erkrath
Max-Planck-Straße 30
Tel. +49 211 540054-0
Fax +49 211 540054-54
erkrath@nordcap.de

Vertrieb Nord
21079 Hamburg
Großmoorbogen 5
Tel. +49 40 766183-0
Fax +49 40 770799
hamburg@nordcap.de

Vertrieb Süd

55218 Ingelheim

Hermann-Bopp-Straße 4

Tel. +49 6132 7101-0

Fax +49 6132 7101-20
ingelheim@nordcap.de

www.nordcap.de

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals