NordCap 447600900 Cool-Line Bakery Refrigerator Instruction Manual
- June 4, 2024
- NordCap
Table of Contents
NordCap 447600900 Cool-Line Bakery Refrigerator
ORIGINAL INSTRUCTIONS FOR USE AND MAINTENANCE
PURPOSE AND USE
These refrigerators (BKS) and freezers (BLF) are used for keeping the bakery
product.
DESCRIPTION
The cabinet consists of a casing, door and superstructure.
- The casing is made of an inner coat and outer coat which are both made from a stainless steel AISI 304. All the angels are rounded, which enable the easy cleaning. We were thinking on low energy consumption and we have constructed a superisolated housing of 70mm. Inside refrigerator there are movable bars placed at different levels.
- The door is also made of a stailess steel AISI 304. The door is locked by means of a lock which is built into the facade. When the door of the refrigerator is open, the refrigerator light switches on and fan switches off.
- The superstructure has a cooling unit built in. It is placed on the refrigerator and can therefore be taken off. There is a cooling equipment in the front and an evaporator with a ventilator in the back. The ventilator sucks the air for the refrigerator through an opening in the top and then blows the cooled air left into the refrigerator from special chenel. If the door is opened, the ventilator stops immediately. In front of the cooling unit there is a facade with electronic controler, which regulates operating of the cabinet. It also shows the temperature in the cabinet and other elements of functioning.
- The interior fittings are composed of support rails placed on the sides and the back of the inner coat. They are made in such a way that their installation is simple and the function is reliable. Shelves are located in special “L” profiles, which are stuck to the rails. Construction of L profiles are made to easy to adjust the height of the shelves with regard to the user’s requirements.
INSTALLATION AND CONNECTION
Transport and unpacking the cabinet
Be sure the cabinet stays in the upright position during transportation.
Wooden support should be removed when remove some nail, which fix the suport
on the cabinet. Stainless steel cabinets are PVC coated and this coat should
be removed before installation. Don’t use sharp tools for removing the coat
because of demaging the stainless steel.
Location of Cabinet
The place where the refrigerator is installed should not be humid nor near hot
places such as stoves, radiators, heaters… The refrigerators must stand in a
horizontal position which can be achieved by installing legs. The place where
refrigerator cabinet is installed should be adequately ventilated or air-
conditioned. Ceilling of the room should be at least 40 cm higher than the
cabinet.
The minimum temperature should not be lower than 10 oC. In a small
unventilated room, the temperature can become excessive especially in hot
weather. Allowed ambient temperature is +10oC to +43oC.
Connection
Before connecting the cabinet, checkthe condition of the cable and plug. If
the supply cable is damaged, it must be replaced by the manufacturer or
similarly qualified persons in order to avoid a hazard.
Connect the cabinet to a line voltage of 230 V and 50 Hz using a wall socket
earthed according to applicable standards. The allowed voltage variation is
±10%. Higher voltage variations will have a negative effect on the cabinet’s
electric equipment, preventing its proper fuctioning and reducing the service
life of the refrigerator.
FUNCTIONING
Switch on
After connection of the cabinet to the electric system, the compressor started
after 1 minutes. The lowest possible temperature on our BKS model is -3o C and
on BLF model is –30o C.
Front panel commands
BLF/BKS
Key combination::
Tolock and unlock the keyboard
To enter in programming mode
To return to the room temperature display
Controlling and Changing of the Actual Setpoint Temperature
By pressing the button SET actual setpoint temperature appears on a display.
After the button SETis released display shows temperature in the cabinet.
A new setpoint temperature could be changed – within factory set limits – by
pressing button SET (for at least 2 seconds so that the refrigerating light )
appear. You setup a temperature with a button . The new value is confirmed by
pressing button SET.
Defrosting
The defrosting of ice on the evaporator surface is automatic. It is switched
on by electronic controller every 6 hours. During defrosting display shows
sign . If the doors are opened very frequently in the ambient with high
humidity, the defrosting could be uncompleted. In this case we can switch on
the defrosting manualy with pressing button for at least 2 second, so that the
defrosting light switch on.
Lighting
The light in the cabinets is switched on automatically when the door is
opened.
Some cabinets contain LED strip or classic bulb. The power of the illumination
is 9W/m for LED strip and 25W for classic bulb.
Power supply for Led is DC 24V and for bulb is AC 240V. The replacing
operations should be done by the manufacturer or similarly qualified persons
in order to avoid hazard.
Alarm
The controller allows a check on the correct operation of the controler.
-
Exceeding of the allowed temperature in the cabinet (indication HAor LA).
HA- The temperature in the cabinet is to high – alarm is switched on after 15 minutes,
LA –The temperature in the cabinet is to low – alarm is switched on after 15 minutes -
Fault of the air temperature probe- indications:
P1, P2, P3, P4 fault of the probe of the temperature in the cabinet, the termostat is stopped immediately, alarm is signalled immediately. The termostat is working normaly. Before changing the probes check the contacts, and see the chapter 6.
Humidity regulation and energy saving
After start LED dioda is lighting. With pressing on the buton we will change
the regim of the fan. In this case LED permanently lighted. In this regime
will be higher humidity in the cabinet and energy consumption will be lower.
Fast cooling (only for CN Models)
By holding on the button for 3 seconds cycled cooling will be switched ON.
After this time the cooling is switched to SET working. With holding on the
button again for 3 seconds, cycled cooling is interrupted.
CLEANING
Cleaning of the Inner and Outer Cout
The inner and outer cout should be cleaned at least four times a year. The
surface of the stainless steel cout could be standing damaged due to irregular
cleaning.
Wipe the outer cout with a soft, damp cloth, and clean the inner cout with
warm water. Cleaning agents may be used. When cleaning the inner cout be sure
to use agents that are odour-free and have no harmful effects on food quality.
The cabinet should then be rinsed with warm water and wiped with a soft cloth.
Leave the door open until the interior has dried.
WHEN CLEANING THE CABINET, THE USE OF PROTECTING GLOVES ARE NECESSARY.
Cleaning of the condenser
The condenser lamellas should be cleaned two to three times yearly with a soft
brush or vacuum cleaner. More frequent cleaning is required if the cabinet is
in a dust-filled environment, since a dusty condenser, will prevent normal
operation of the refrigerator.
MAKE SURE TO DISCONNECT THE POWER CORD FROM THE WALL SOCKET WHEN CLEANING THE
CONDENSER AND OTHER EQUIPMENT IN THE UPPER SECTION OF THE CABINET.
TROUBLESHOOTING
TROUBLE | 6.1.1 DISPL AY | COMMON CAUSE | REMEDY |
---|
Unit will not run
| ****
No sign
| Blown fuse| Replace fuse
No voltage in the socket| Check and repair the socket
Electric lead is damaged| Replace electric lead- Call the
ingeneer
The controller is spoilt| Call the ingeneer
Refrigeration section is to warm
| ****
Alarm – Indication HA
| The door is opened too often| Reduce number and lenght of the
door openings
Overloading of shelves, blocking
normal air circulation in cabinet
| Load on the shelves just to the height
mark
Warm or hot foods placed in
cabinet
| The food placed in cabinet must be
cold
Poor door seal| Change the door gasket
The controller is set on too high
temperature
| Set the controller on lower
temperature
Dirty conderser| Clean the condenser
Too much ice on the evaporator – uncompletly defrosting| Switch manual
defrosting on; if there is no improvement after 4 hours, call
the engineer
Refrigeration section is to cold| Alarm –
indikation LA
| The controller improperly set| Set higher temperature
Compressor runs for 15 min and is stopped for 30 min without regard to the
temperature in the
cabinet
| Alarm – indication P1, P2, P3, P4| The controller probe of the temperature
is broken| Call the engineer
»dA« alarm on the screen| Alarm –
Indikation »dA«
| Magnetic switch doesn’t recognize
closed door.
| Check position of switch above door.
TECHNICAL DATA
Type: | BKS 600 | BLF 600 | BKS 900 | BLF 900 |
---|---|---|---|---|
Cooling temperature ( ° C) | -3 / +10 | -5/-30 | -3 / +10 |
-5/-30
External dimensions (mm)
Width| 780| 780| 780| 780
Depth| 680| 680| 960| 960
Depth-open door| 1415| 1415| 1695| 1695
Height| 2000| 2000| 2000| 2000
Internal dimensions (mm)
Width| 640| 640| 640| 640
Depth| 540| 540| 820| 820
Height| 1460| 1460| 1460| 1460
Net volume (l)| 505| 505| 766| 766
Net weight (kg)| 120| 130| 145| 155
Refrigerant| R404a
R290
| R404a
R290
| R 404a
R290
| R404a
R290
Energy consumption (kWh/24h)| 2,5| 8| 4,1| 10
Rated voltage (V/Hz)| 230 / 50| 230/50| 230 / 50| 230/50
Rated power (W)| 335| 821| 501| 977
Starting current (A)| 10.6| 18| 12.8| 24
Rated current (A)| 2,1| 3,1| 2,7| 3,5
Maximal load no. of L profil – pair (kg)| 10x 12kg| 10x 12kg| 10x 12kg|
10x 12kg
A-weighted emission sound pressure| below
70 dB(A)
| below
70 dB(A)
| below
70 dB(A)
| below
70 dB(A)
SIGN EXPLANATION
Outer coat | SS-AISI 304 |
---|---|
Inner coat | AISI 304 |
Working zone | BKS -3 / +10 °C |
BLF -5 / -30 °C
REMOVAL AFTER USE
The removal of products after their use should be environmentally friendly.
Products should be delivered to a company which specialises in complete
removal.
The table below lists all details of removal and repeated use of individual
component parts of the product:
Product | Material | Removal |
---|
Steel construction
frames, engines, propellers pipelines, drawers
|
Metals
| Separation of material melting procedure for
repeated use (recycling)
Insulated casings
insulated doors
| Metals, PU foam| Separation of materials special incineration procedure
Cables
casings, plugs
| Rubber, PVC, silicone,
similar artificial materials
| Separation of materials
recycling
Electronic assemblies| Artificial materials, metals
electrolytes
| To special waste dumps in compliance with all local
regulations
Gasoline, flammable liquids|
R290
| Do not store or use gasoline, or other flammable liquids in the vicinity of this or any other appliance. Read product labels for
warnings regarding flammability and other hazards.
Products with coatings should be delivered for processing to enable their repeated use, depending on the type of coating, or be taken to special waste dumps in compliance with all local regulations.
WARNING!
If you will not be using the refrigerator/freezer cabinet for a longer period
of time or are replacing it with a new one, make sure that the lock is not
functioning. This will prevent children from locking themselves into the
cabinet.
If is used flammable refrigerants, you should read and understood Annex
FLAMMABLE REFRIGERANTS.
THIS APPLIANCE COMPLIES WITH THE MACHINERY DIRECTIVE 2006/42/EC, THE LOW
VOLTAGE DIRECTIVE 2014/35/EU AND WITH THE ELECTROMAGNETIC COMPATIBILITY
DIRECTIVE 2014/30/EU.
NordCap GmbH & Co. KG
Thalenhorststraße 15
D-28307 Bremen
Telefon: +49 421 48557-0
Telefax: +49 421 488650
E-Mail: info(at)nordcap.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>