Horizontal Co-Linear Vent Kit Installation
Installation:
Note: Space must be left for the gas line on left side (Q1/E30/EX32) or
right side (E33/EX35) of the unit for servicing purposes
Install Information:
The flue damper must be fully blocked open or removed for installation of the
unit; the smoke shelves, shields and baffles may be removed if attached by
mechanical fasteners. The fireplace and fireplace chimney must be clean, in
good working order and constructed of noncombustible materials. Make sure that
all chimney cleanouts are tight fitting and will not permit air to leak into
the chimney. Refractory, glass doors, screen rails, screen mesh and log grates
can be removed from the fireplace before installing the unit. Install a sealed
vent cap to prevent leakage of room air up through chimney. The intake and the
exhaust are 3” (76mm). Ensure that the fireplace and chimney have been
thoroughly cleaned prior to install.
Initial Installation
Q1 General Information
The Horizontal Vent Kit (50-3664, ICC #TM-ALH) must be used in conjunction with the Q1 Co-linear Vent Kit (50-2982) and ensure that the unit air restrictors are set to fully open as this venting kit functions best without any restriction. See owner’s manual for more information. See Owner’s Manual for installation. This kit is NOT compatible with the Q1 fireplace configuration. The kit is directly compatible with the E & EX series units listed below
All Inserts General Information
Compatible Models:
- Q1C
- Q1CI
- Q1L
- Q1LI
- Q1G
- Q1GI
- E25
- E25I
- E30
- E30I
- E30G
- E30GI
- E33
- E33I
- E33G
- E33GI
- EX32
- EX35
Step 1:
Remove the Horizontal Vent Kit from the packaging. Ensure there is no damage
to the vent piping or termination cap. If there is damage contact your dealer,
distributor, or courier company before starting this installation.
Step 2:
Determine the best location on the exterior wall of the chimney for the vent
terminal. Use Figure 3 and Table 1 as reference for the minimum vertical
venting run required. Note: A taller vent run will allow for a cleaner burning
flame
Step 3:
Proceed to core or drill a hole at the predetermined height. Figure 1 provides
dimensions for the required cut-out.
Step 4:
Prebend the intake and exhaust venting, do NOT exceed 90 degrees. After the
elbow, stretch the venting to the desired vertical height.
Step 5:
Attach the venting to the wall terminal using the supplied hose clamps. Note
the exhaust inlet is the inlet with the reducer as seen in the Figure 2
Step 6:
Feed the stretched venting into the exterior hole and down the chimney. This
kit can be used from 3’-7’ (see Table 1), trim any excess vent as needed.
Mount the wall terminal to the chimney with screws. Seal as per local codes
and regulations.
Step 7:
Ensure that the vent length is correct, and the venting is not crimped or
overstretched.
Step 8:
Attach the venting to the top of the fireplace using 3 screws per vent. Making
sure the intake is on the intake collar. The intake collar is on the left side
of the fireplace for the Q1 and is indicated on the flue collar of the E
series units by the “IN”.
Step 9 [E30 & E33 installations only]:
Set the adjustable plate located in the firebox baffle to the most open
position using a Torx T20 screwdriver. Refer to the Owner’s Manual for further
information.
Fireplace Model | Minimum Vent | Maximum Vent |
---|---|---|
Q1G / Q1GI / Q1L / Q1LI | 3’ [0.9m] | 5’ [1.5m] |
Q1C / Q1CI | 5’ [1.5m] | 7’ [2.1m] |
E30 / E30I / E30G / E30GI | 6’ [1.8m] | 7’ [2.1m] |
E33 / E33I / E33G / E33GI
EX32 E25 E25i
EX35
* Minimum vertical height is measured from the top of the unit to the
intake collar center line
** Maximum vertical height is measured from the top of the unit to the
exhaust collar center line.
Step 10:
Proceed with regular installation for the given model as shown in the owner’s
manual.