NordCap 46710803002-G-F-0 Freezer Unit
NOTES
We would like to thank your preference for ur equipment, which follow all the European Directives and Standards and will meet for sure, your expectations and satisfy your needs. Thank you
Instruction Manual
Reception
On receiving the equipment, check carefully that the packaging is intact and has not been damaged in transit. After unpacking, check that you have all the components and if the characteristics correspond to those on the order form. Installation, maintenance and other work should be carried out by specialised and authorised manufacturer accepts no responsibility and will not cover the guarantee if these conditions are not respected. technicians. The This appliance must be used according to this manual and only for the manufacturer’s purpose. The incorrect use of the equipment cAas na craeususelt doaf mouar gceosn tsot athnet eefqfouript mtoe mnta akned t etoc h unsoelros.g ical improvements, the specifications indicated here are subject to change without warning.
Rating Plate
The rating plate on our cold rooms Cooling units is located at the outside lateral of the cover. It includes the main technical data about the equipment and it identifies the MODEL and SERIAL NO., which are vital pieces of information for any queries to the manufacturer
The European directive on Waste from Electrical and Electronic Equipment (WEEE) specifies that, at the end of its life cycle, the equipment and all of its components, subassemblies and consumable materials should be sent separately for treatment for it to be destroyed, recycled or reused. Do not put equipment with this symbol together with unseparated urban waste.
Recommendations for Installation
General Notes
Although fhe producfion and operafion (as prove the enclosed fest report) of each applidnce is ngorously confrolled dining manufactfure, this does not exclude the possibility of damage caused in ftransif. The general condifion of the appliance should fherefore be checked on arrival.
Placing
- Remove the packaging or pallet carefully so that the equipment’s surfaces are not damaged. Remove the PVC protection.
- The appliance should be installed away from heat sources (ex: heating appliances) and direct sunlight.
- The air vents should never be covered or blocked – must be guaranteed free space to this areas, assuring a good air circulation.
Installation
The following standards should always be bared in mind during installation:
- Rules concerning accident prevention.
- European standards into effect.
- The appliance is supplied with a plug complying test standards, and with a regulation power cord long, enough to allow connection to the electric socket.
- The socket should be easily accessible and the right size for maximum consumption (see identification plate). It must have an EARTH WIRE.
- Never use sockets or plugs without an earth wire, nor should you use adapters or extensions.
- For direct connections to the current, a circuit breaker must always be installed. This complies international standards.
Replacement of Power Cord
If the power cord is damaged, this must be replaced by the manufacturer, by
its technical services or by qualified person to avoid danger.
Connection of Door Resistance
All the cold rooms with 80 and 100 panels have a preinstallation of door
resistance. The cold rooms with 100 panels are freezer cold rooms, those with
80 and 100 panels can havea posifive and negative temperature. Usually, the
door resisfance is appropriate fo be used in freezer cold rooms and must be
connected only in this kind of equipment.
Working on the exterior of the cold room, you must proceed to the connection
of the door resistance as follows:
- Fix the cord that you can find on the cooling unit, spare part A (Fig. 1).
Photocell
Whenever you open the door, the lightning switches on and the motorfan stops.
These operations are controlled by a photocell in fhe interior of cold rooms.
The photocell is delivered without being installed. This one must be installed
in a place where there is the most light when you open the door. You must
install if using the cable fies sent with the machinery documents.
Recommendations for the User
This cooling unif has been designed for cold rooms (cold room panels). This equipment has been created fo work at a4 climatic class (30°C room temperature, 55% Hr). Children should be supervised to ensure that they do not play with the device. To ensure that they function well, the following points must be followed
- Do nof block fhe fronfal air vent as this will senously affect fhe eficiency of the compressor.
- Do nof use pointed objects to remove ice that could damage the evaporator and be dangerous to health and environment.
- If you do not follow the above advises, there will be an increase USage electrical energy.
Start-up
Make sure that the plug is correctly inserted in the socket or that the
appliance’s circuit breaker is on.
To connect the equipment, besides the following information, you must consult
the microprocessor technical schedule.
- Pdrisepssla byu wttioll nfla “sAh” f,o pr lsaocmineg s iet cino nthdes u“nOtNil ”it ipnodsicitiaotne. sT thhee ginreneern t eligmhpt ewraill tucroem. e on and indicate connection. At the same time, the
- The “B” button switches on and off the light inside the cold room.
- Temperature is controlled automatically through the electronic thermostat “C”.
IR33 Microprocessor Instructions
Definitions
Set Point (St) – The lowest temperature in C inside the cabinet.
Differential (rd)- Interval of temperature in °C for the working of the
cabinet.
SET POINT modification
- Press the Set for 5 second;
- Use the key def or aux to change the value:
- Press fhe Set key for 5 seconds fo confim the new value.
Change of the Differential
- Press the Set key and Pra for 5s;
- Ihrough the auX key, infroduce fhe value 22, you are now in the paramefers;
- Press the def key or aux fil you reach fhe parameter rd;
- Press Set;
- Press the key def or aux fo modify the value;
- Press Set
- Press the key Prg for 5 seconds fo memorise the value.
Configuration for HACCP control on IR33 controllers
All fhe microprocessors Used in our products have HACCP, or the microprocessor possesses this funcfion, or the client can buya HACCP module fo be used on the equipment. Through ifs programming, the HACCP, guaranfees the temperature confrol of stocked products. The HACCP realises an automatic monitoring of the unity, recording and indicating any abnormal situation. When it happens it produces a warning signal. The reached femperafure during the occurence, as well as its duration are recorded on the pemanent memory (EEPROM). The HACCP indicates the loss of volfage occurred during the fime when if was impossible fo mainfain the requested femperafure.
Defrost
goes on according to the defrosting stage. Affer defrosting the switch goes off The appliance defrosts aufomafically. SwifchaUTomaically – IT Is aiso possible To do manua defrosting (besides ne ones aireddy programmed), Tor so you JUST nave fo press the def key for 5s.If is advisable not fo open the doors after defrosting so that the nomal temperature is obtained more rapidly. Our cold rooms have automatic defrosting.
Cleaning
To ensure perfect hygiene and conservation, please clean as follows:
- Cleaning fhe surfaces carefully wifh a damp clofh.
- Always when Using water and detergent, make sure fhese are neutral, and avoiding those which are chlorine-based or abrasive.
- Rinsing with clean water and drying carefully.
- lf is enfirely inadvisable fo Use pressurised jets of wafer, especially in the direction of the compressor.
Maintenance
To ensure fhat the cooling system lasts for a long time and functions
corecfly, regular mainfenance of fhe condenser should be camed out. This
shOuld be done in the following way:
- Switch off the appliance and unplug it.
- Open the compressor compartment; the condenser will be easily accessible.
- Pass the vacuum cleaner across the condenser in the slat’s direcfion.
- Be careful not fo sfrefch the cables, do not stretch them. Remember fo close the compartment.
Prolonged Inactivity
When long periods of inactivity are foreseen, the following procedure is
recommended:
- Unplug the appliance.
- Cary ouf mainfenance operafions.
Anomalies
If you nofice any anomalies or malfunctions, before calling the fechnical
services, check that:
- The general switch is on.
- The equipment is not near any heat sources.
- The condenser is clean and the fan motor is functioning.
- There is not foo much ice on the evaporator.
If the problem persists, it Is recommended that you remove everything from
inside the appliance, unplUg it, and seek technical assistance.
Note: Specialised staft must cary out maintenance and the manufacturer
declines any responsibility for the use of unauthonsed parts that cancel the
guaranfee.
Finanzen/Service 28307 Bremen
Thalenhorststraße 15 Tel.+49 421 48557-0 Fax+49 421 488650 bremen@nordcap.de
Vertrieb Ost 12681 Berlin
Wolfener Straße 32/34, Haus K Tel.+4930 936684-0 Fax+49 30936684-44
berlin@nordcap.de
Vertrieb West 40699 Erkrath
Max-Planck-Straße 30 Tel.+49 211 540054-0 Fax+49 211 540054-54
erkrath@nordcap.de
Vertrieb Nord 21079 Hamburg
GroBmoorbogen 5 Tel.+49 40 766 183-0 Fax+4940 770799
hamburq@nordcap.de
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>