MEAN WELL SE-1500 1500W Single Output Power Supply Instructions
- June 8, 2024
- MEAN WELL
Table of Contents
MEAN WELL SE-1500 1500W Single Output Power Supply
Features
- AC input 180 264VAC
- AC input active surge current limiting
- Protections : Short circuit/Overload/ Over voltage/
- Over temperature
- Forced air cooling by built-in DC ball bearing fan
- High power density 7.8w/inch
- With DC OK signal output
- Built-in remote ON-OFF control
- Built-in remote sense function
- UL/ CUL approved
- Low cost
- 2 years warranty
SPECIFICATION
MODEL| SE-1500-5| SE-1500-12| SE-1500-15| SE-1500-24|
SE-1500-27| SE-1500-48
---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 5V| 12V| 15V| 24V| 27V| 48V
RATED CURRENT| 300A| 125A| 100A| 62.5A| 55.6A| 31.3A
CURRENT RANGE| 0 ~ 300A| 0 ~ 125A| 0 ~ 100A| 0 ~ 62.5A| 0 ~ 55.6A| 0 ~
31.3A
RATED POWER| 1500W| 1500W| 1500W| 1500W| 1501.2W| 1502.4W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 150mVp-p| 150mVp-p|
150mVp-p| 150mVp-p| 150mVp-p
VOLTAGE ADJ. RANGE| 3.3 ~ 5.5V| 10.8 ~ 13.5V| 13.5 ~ 16.5V| 21.6 ~
26.4V| 25 ~ 30V| 43.2 ~ 56V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 150ms, 12ms / 230VAC at full load
HOLD UP TIME (Typ.)**| 26ms / 230VAC at full load
INPUT
| VOLTAGE RANGE| 180 ~ 264VAC 254 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 81%| 85%| 85%| 87%| 88%| 89%
AC CURRENT (Typ.)| 17.5A / 230VAC
INRUSH CURRENT (Typ.)| 60A / 230VAC
LEAKAGE CURRENT| <3.5mA / 240VAC
PROTECTION
| ****
OVERLOAD
| 105 ~ 125% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE
| 5.75 ~ 6.75V| 14.5 ~ 16.2V| 18 ~ 21V| 27.6 ~ 32.4V| 31 ~ 35V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION
| DC_OK SIGNAL| PSU turn on:3.3V ~ 5.6V PUS turn off:0 ~ 1V
REMOTE CONTROL| RC+/RC-: 0 ~ 0.8V power on; 4 ~ 10V power off
ENVIRONMENT
| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 4)
| SAFETY STANDARDS| UL62368-1, BSMI CNS14336-1, EAC TP TC 004 approved;
Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32)| Class B
Radiated| BS EN/EN55032 (CISPR32)| Class A
Harmonic Current| BS EN/EN61000-3-2| —–
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN55024, BS EN/EN61000-6-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT / Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-6-2| 2KV/Line-Line 4KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS
| MTBF| 333.3K hrs min. Telcordia SR-332 (Bellcore) ; 134.5K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 278177.863.5mm (LWH)
PACKING| 3.3Kg; 4pcs/14.2Kg/1.14CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load and 2 ℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
. The ambient temperature derating of 3. ℃/1000m with fanless models and of ℃/1000m with fan models for operating altitude higher than 2000m(6 00ft).
6. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply under the following conditions:
a) the end-devices is used within the European Union, and
b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
c) the power supply is:
– installed in end-devices with average or continuous input power greater than 7 W, or
– belong to part of a lighting system Exception:
Power supplies used within the following end-devices do not need to fulfill EN61000-3-2
a) professional equipment with a total rated input power greater than 1000W;
b) symmetrically controlled heating elements with a rated power less than or equal to 200W
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
Terminal Pin No. Assignment
Pin No. | Assignment |
---|---|
1 | AC/L |
2 | AC/N |
3 | FG |
Control Pin (CN3) : JST B6B-XH or equivalent
Pin No. | Assignment | Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|---|---|
1 | DC_OK Signal | 4 | +S | JST XHP |
or equivalent
| JST SXH-001T
or equivalent
2| DC_OK GND| 5| RC-
3| -S| 6| RC+
Block Diagram
Derating Curve
Static Characteristics
Function Description of CN3
Pin No. | Function | Description |
---|---|---|
1 | DC_OK | DC_OK signal is a TTL level signal, referenced to pin2(DC_OK GND). |
“High” when PSU turns on.
2| GND| This pin connects to the negative terminal (-V). Return for DC_OK
signal output.
3| -S| Negative sensing. The -S signal should be connected to the negative
terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect.
4| +S| Positive sensing. The +S signal should be connected to the positive
terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect.
5| RC-| Return for RC+ signal input.
6| RC+| Turns the output on and off by electrical or dry contact between pin 6
( RC+) and pin 5 (RC-). 0~0.8V: Power ON, 4~10V: Power OFF.
Function Manual
- DC_OK Signal
DC_OK Signal is a TTL level signal. “High” when PSU turns on.Between DC_OK(pin1) and GND(pin2)| Output Status
---|---
3.3 ~ 5.6V| ON
0 ~ 1V| OFF
- Remote Control
The PSU can be turned ON/OFF by using the “Remote Control” function.Between RC+(pin6) and RC-(pin5)| Output Status
---|---
SW OFF (0 ~ 0.8V)| ON
SW ON (4 ~ 10V)| OFF