GENERAL INFORMATION

General Conditions
For your safety and the proper use of the equipment, please read these instructions carefully and comply with the warnings and recommendations contained therein before installing the equipment for the first time.
You should keep these instructions in a safe and dry place and always accessible to the user as they contain important information on equipment installation, operation, and maintenance. Keep all documentation for your own use or for another person who may come to own this equipment in the future.
Proper installation and rational use, in accordance with these instructions, will enable a better performance of the equipment.
Restrictions of Usage and Maintenance
The models KK 601 are designed for the chilling and preservation of fresh produce and beverages.
The models KF 611 are designed for the preservation of frozen products

SAFETY INSTRUCTIONS

General Safety

  • The use and handling of this equipment is not recommended for children and persons with reduced mental, physical, or sensory abilities. The use of the equipment by persons with little experience or knowledge of the operation of the equipment is also not recommended unless accompanied and supervised by a person who has been duly instructed and made responsible for their safety.
  • Children should not play with the equipment!
  • Keep the packaging and all its components out of the reach of children. Choking hazard! The package may contain cartons or films.
  • Before connecting the equipment, check if the cable and power cord have been damaged during transport. In the event of damage, it must be replaced immediately by the manufacturer or its authorized dealer in order to avoid risk of electrocution.
  • The operating conditions of the equipment are shown on the nameplate inside the equipment, by means of the climate class indicator. The equipment can be classified according to the classes:
Climate Class Max. Environment Temperature Max. Relative Humidity
3 25 °C 60%
4 30°C 55%
5 40 °c 40%

The minimum operating temperature is 10 °C
Technical Safety:

  • This equipment has a small amount of refrigerant (R600a or R290, depending on the model) which, while not non-polluting, is flammable. Care should be taken to ensure that the refrigerant tube is not damaged during transportation or assembly. The refrigerant may cause damage to the eyes or ignite when released.

In case of damage:

  • Keep the equipment away from naked flames or ignition sources;
  • Air out the cabinet well for a few minutes;
  • Disconnect the plug from the mains;
  • Contact the technical service.
  • The compartment where the equipment is installed should be as big as necessary for the refrigerant in the appliance. In very small spaces and in the event of a leak, a flammable gas/air mixture may form.
  • The compartment should be at least 1m³ for every 8 gr of refrigerant. The amount of refrigerant in the appliance is indicated on the rating plate inside the same appliance
  • Replacement of the electrical cable and other repairs may only be carried out by qualified service personnel in order to prevent dangerous situations. Improper installation and repairs can result in a number of hazards to the user.

Usage Recommendations:

  • Do not touch the appliance with wet or damp hands and feet;
  • Disconnect the equipment from the socket by pulling on the plug, not the power cord;
  • Never use electrical appliances inside the equipment (e.g. heaters, electric ice cream makers, etc.) Risk of explosion!
  • Do not store flammable products in the appliance (e.g. spray cans) and explosive products. Risk of explosion!
  • Keep alcoholic liquids with a high alcohol content in a hermetically sealed container and in a vertical position;
  • To defrost and clean, unplug the appliance from the wall socket;
  • Never use mechanical devices or other means to speed up the defrosting process other than those recommended by the manufacturer (e.g. defrosting or cleaning the appliance with a steam cleaner! The steam can reach the electrical components and cause a short circuit. Electrical shock hazard!
  • Do not use any pointy objects or with sharp edges to remove single or layered ice. This may damage the tubing where the refrigerant circulates, and this may freeze, ignite, or cause injury to the eyes!
  • Do not damage the refrigerant circuit;
  • In the case of lockable appliances, keep the key out of the reach of children!

INSTALLATION

Unpacking the Equipment
Unpack the cabinet by removing the packaging as well as its protective packaging and packing base. Choose the storage place for the removed products carefully, keeping them out of the reach of the children, trying whenever possible to leave them in a place where they can be recycled.
Transport and Handling of Equipment
Make sure the equipment has not been damaged during transportation. If you find any damage, you must notify the carrier and mention it on the delivery note.
If the equipment is moved horizontally during transportation, it must remain vertically for a period of not less than six hours before being connected to the mains.
Lifting, moving, and transporting the appliance without proper equipment can cause personal injury or damages. Use proper lifting means to load, unload, and move equipment whenever necessary.
Never move the equipment with products inside. Before moving the equipment, unplug the equipment from the socket and remove the products from inside, storing them away.
After proper storage, check that the power cord is not damaged. A damaged power cord may cause electric shock or fire. If the power cord is damaged, it must be replaced by the manufacturer, authorized dealer, or qualified personnel in order to avoid danger.
Positioning of the Equipment

The equipment must be installed in a dry and ventilated area, on a levelled floor with the capacity to support its weight, including its maximum load. It must be positioned so that the plug is accessible.
You should avoid moving the cabinet when it has products inside.
Install the equipment leaving 5 cm between the appliance and any other furniture or wall, thus allowing for a natural circulation of air.
In order to reduce energy consumption, the equipment should be kept away from any source of heat and out of direct sunlight. Do not obstruct the lower and/or upper fan grills to allow for ventilation and maintenance.
Before Switching On
Before you start the appliance for the first time, you should clean it inside with a non-alkaline cleaning solution (do not use corrosive products) and then dry thoroughly. The equipment must be disconnected from the mains while this is done.
Connect to the mains
Before connecting the equipment to the mains, check that the voltage and frequency are in accordance with the specifications on the rating plate. The appliance must be connected to anearthed socket; ensure that the connecting cable does not become entangled.
If the length of the cable is not enough, it should be replaced by a qualified person. Do not use an extension cord.

OPERATION

Carel controller

The factory set point in positive refrigerated equipment is +3°C, and can be set on the thermostat between + 1˚C and + 10˚C.
In the negative cold models, the factory set point is -20˚C, and can be adjusted in the thermostat between -16˚C to -22˚C.
In sub-zero models, the factory set point is -2˚C, and can be adjusted between -3˚C and + 10˚C.

Operating Message

Message| Description
E0| Ambient Probe Failure
E1| Defrost Probe Failure
L0| Low Temperature Alarm
HI| High Temperature Alarm
DF| Defrosting in progress
OFF| Standby
Door| Open Door
ENS| Energy Saving Mode

To switch off, press the ON/OFF button (information “OFF” on the display, equipment off) or disconnect the plug from the mains. Wait 10 minutes before turning the equipment back on.
Product Loading
Load the products in the equipment ensuring they are properly packed, avoiding accidents when handling.
Some equipment may have a load limit and are marked with a special sticker if this is the case. Do not place products above this limit otherwise it will affect the normal operation of the unit.
The maximum permissible load per shelf is 40 kg/m.
On digital thermostats, when the equipment is fully loaded, it is possible for the alarm to go off after 2 hours if it has not yet reached the set temperature. Press the “mute” button to turn the alarm off and wait for 12 hours for the temperature to stabilize. If the set temperature has not been reached within that time, please contact our technical services or our dealers.

Defrosting

Positive Cold Storage Models
In the case of models with digital thermostat, defrosting is automatic and controlled by the thermostat itself. The cycle is pre-set at the factory for 20 minutes every 4 hours, except for equipment with two probes in which the time between defrosting is 6 hours for 20 minutes (only if necessary).
Negative Cold Storage Models
For other negative cold equipment, defrosting is manual and should be carried out at least every 6 months. Disconnect the mains plug from the wall outlet and allow the unit to defrost.
Place a container under the front drainpipe, remove the plug from the inner drain hole and wait for the ice to thaw (do not use hot water).
Do not use sharp objects to remove ice as these may damage the inside of the equipment. Do not use mechanical, electrical, or chemical processes to speed up the defrosting process.

MAINTENANCE

CAUTION: The equipment’s power cord must be disconnected from the mains before any inspection, maintenance, and cleaning work so as to avoid any electrical shock or injury. During maintenance, do not breathe in dust or aerosols near the equipment as they may be harmful to your health.
Frequent and correct maintenance is essential to ensure performance and functionality of the equipment, consequently, maintenance is recommended at least twice a year and cleaning at least once a month;
The following operations must be carried out for efficient maintenance:

  • Lubricate the hinges and gaskets. Wipe off any excess lubricant;
  • Check that the appliance is levelled. If necessary, adjust the levelers/feet;
  • Inspect all seals and gaskets. Make sure they are still soft and flexible.

Keep the equipment clean by avoiding the build-up of dust or other materials in the ventilation grills.
Maintenance operations must be carried out by the manufacturer, the service agents, or
qualified personnel in order to avoid danger. They should not be carried out by children without supervision.
Cleaning:

  • The equipment should be cleaned at least once a month. The following operations are to be carried out:

  • Always keep the equipment free of ice. Use a soft cloth or soft brush to remove loose ice.
    Never use sharp tools and be careful not to damage the seal. Keeping the equipment free of ice prolongs its useful life;

  • Clean the outside and inside of the appliance with a dry, soft cloth or water and a neutral detergent solution;

  • Clean all seals and gaskets using a damp cloth. Remove all dirt and wipe off with a dry cloth afterwards;

  • Do not spill water directly into the equipment. Water spills can damage insulation materials and electrical components;

  • Remove dust from the inside of the compressor compartment using only a dry brush or vacuum cleaner;

The cooling system parts of this unit are completely sealed. They do not require any lubrication.

REVERSING THE DIRECTION OF THE DOOR

KF 611 E and KK 601 E this operation must be done in the factory.
REPLACEMENT OF LIGHTING (applicable Models)
LED lights, with power equal to 12W/m. 12V DC power supply.
This operation must be carried out by the manufacturer, authorized representatives, or qualified personnel in order to avoid danger.

TROUBLESHOOTING GUIDE

Problem Solution
The Appliance is not working Check for power outage

Check if there is current in the socket
The equipment works, but it is not very cold| Check for the build-up of dust on the condenser
Check controller setting
Check if fans (when applicable) are working or are stuck
Check ice build-up on the evaporator
Check that the door is properly closed
Water appears on the bottom of the equipment| Check that the drain hole is not blocked or that the tube is not in the direction of the recipient in the compressor compartment
Check equipment levelling
High temperature alarm (HI)| Check ice build-up on the evaporator
Check that the fans work (when applicable)
Make sure the door was not left open for too long
Low temperature alarm (LO)| Check thermostat temperature
Turn the equipment off for 5 minutes and then switch on again
Lighting does not work| Turn the digital key on/off with the light switch function
Excessive build-up of ice (negative cold storage models)| Check the temperature and humidity of the environment in which the equipment is inserted, according to the climatic class shown on the nameplate.
Check door seal
Damaged power cord| If the power cord is damaged, it must be replaced by the manufacturer, authorized service agent, or qualified personnel in order to avoid danger

Repair Guide:

If the malfunction continues after these checks, technical assistance should be requested from your authorized dealer.
Please indicate the type of malfunction, type of appliance, serial number, and date of purchase (invoice). The serial number and type of appliance are described on the equipment information label (normally located inside the equipment, on the side).
In case of need for accessories or spare parts, you should also request them from your authorized dealer, always mentioning the equipment data described above.
Note: For the protection of persons and property against direct/ indirect contacts, the use of a differential protection of the power outlet directly to this equipment with a trip sensitivity of 300 mA is mandatory.

RECYCLING INSTRUCTIONS

Recycling of the Packaging
The packaging protects your equipment from damage during transportation. The materials used are reusable.
Be attentive to the storage area of the products used for packaging the equipment and always keep them out of the reach of children, leaving them, whenever possible, in a place where they can be recycled.
Help us protect the environment by recycling the packaging. Contact your service agent or municipal services for information on how to proceed.
Recycling of Used Equipment
This appliance is marked in accordance with the European Directive 2012/19 EC on electrical and electronic equipment (Waste of electrical and electronic equipment – WEEE). The Directive defines the manner for collection and treatment of end-of-life appliances in EC countries. Used appliances are not worthless rubbish. Disposing of them while respecting the environment will allow us to get back precious raw materials.
WARNING!

  • This is an out-of-service appliance therefore:
  • Disconnect the plug from the mains;
  • Do not use the power supply cord.

Refrigeration equipment contains refrigerant and chemical compounds in the insulation. Both should be properly disposed of. Care should be taken not to damage the refrigerant tubing until it is properly recycled. Do not puncture the compressor or piping (risk of explosion and oil spillage

EU DECLARATION OF CONFORMITY

Ref. Ares In accordance with EN ISO 17050-1:2004

Model number (unique identification of the product): KK 601 E
Name and address of the manufacturer or his authorised representative:

Scandomestic A/S
Linåvej 20
8600 Silkeborg
Denmark
This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer):| Scandomestic A/S
Linåvej 20
8600 Silkeborg
Denmark
Object of the declaration (identification of product allowing traceability. It may include a colour image of sufficient clarity to enable the identification of the product, where appropriate.)
Product: Service Cabinet
Brand: Scancool
Colour: White
Model name: KK 601 E| .
The object of the declaration described in point 4 is in conformity with the
relevant Union harmonisation legislation:| EN 61000-3-2
References to the relevant harmonised standards used, or references to the
specifications in relation to which conformity is declared:| EN 60335-1:2012+AC:2014+A11:2014 +A13:2017+A1:2019+A2:2019+A14:2019, EN 60335-2-89:2010+A1:2016 +A2:2017, EN 50366:2003+A1:2006, EN 550141:2017+A11:2020, EN 55014-2:2015, EN 610004-1:2016, EN 61000-4-2:2009, EN 61000-44:2012, EN 61000-4-5:2014, EN 61000-4-6:2014,  EN 61000-4-7:2002+A1:2009, EN 16825:2016, EN 2014/35/UE, 2014/30/UE, 2006/42/CE, 2015/1095
Where applicable: the notified body … (name, number)… performed …
(description of intervention)… and issued the certificate:| RoHS
Additional information:| Ref. Ares In accordance with EN ISO 17050-1:2004

  EU DECLARATION OF CONFORMITY

MK12:L20odel number (unique identification of the product): KF 611 E
Name and address of the manufacturer or his authorised representative:

Scandomestic A/S
Linåvej 20
8600 Silkeborg
Denmark
This declaration of conformity is issued under the sole responsibility of the
manufacturer (or installer):| Scandomestic A/S
Linåvej 20
8600 Silkeborg
Denmark
Object of the declaration (identification of product allowing traceability. It
may include a colour image of sufficient clarity to enable the identification of
the product, where appropriate.)
Product: Service Cabinet
Brand: Scancool
Colour: White
Model name: KF 611 E|
The object of the declaration described in point 4 is in conformity with the
relevant Union harmonisation legislation:| EN 61000-3-2
References to the relevant harmonised standards used, or references to the
specifications in relation to which conformity is declared:| EN 60335-1:2012+AC:2014+A11:2014 + A13:2017+A1:2019+A2:2019+A14:2019, EN 60335-2-89:2010+A1:2016+A2:2017, EN 50366:2003+A1:2006, EN 55014-1:2017 +A11:2020, EN 55014-2:2015, EN 61000-41:2016, EN 61000-4-2:2009,
EN 61000-4-4:2012,  EN 61000-4-5:2014, EN 6100-4-6:2014, EN 61004-7:2002+A1:2009, 2014/35/EU, MD 2006/42/EC, 2014/30/EU, IEC 603351:2010+A1:2013+COR1:2014+A2:2016, IEC  60335-2- 9:2010+A1:2012+A2:2015, EN 603352-89:2010+A1:2016+A2:017, EN
50366:2003+A1:2006
Where applicable: the notified body … (name, number)… performed …
(description of intervention)… and issued the certificate:| RoHS
Additional information:|

Scandomestic A/S
DK-8600 Silkeborg
Tel.: + 45 7242 5571
www.scandomestic.dk

Documents / Resources

| scandomestic KK 601 E, KF 611 E Fridge [pdf] User Manual
KK 601 E, KF 611 E, KK 601 E KF 611 E, KK 601 E KF 611 E Fridge, KK 601 E Fridge, KF 611 E Fridge, Fridge
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals