YAMAN S12-1-001E ace beauty instrument User Manual

June 5, 2024
YAMAN

S12-1-001E ace beauty instrument
User ManualYAMAN S12-1-001E ace beauty instrument

Introduction

Thank you for purchasing a YA-MAN product.

  • Please read this User’s Manual carefully for information on how to use the device properly and safely.
  • After reading the contents hereof, be sure to keep this User’s Manual in an accessible location.
  • Make sure to include this User’s Manual if you are transferring ownership of the device to another person.

Safety Precautions

  • Read these Safety Precautions carefully before using the device in order to use it correctly.
  • Use the device sensibly in accordance with the prescribed steps.
  • Immediately discontinue use and arrange to have the device repaired if any abnormality occurs.
  • Do not use the device in a defective state, as doing so could cause physical harm to the user.
  • The precautions listed in the User’s Manual are very important. For your safety, please follow them carefully.
  • Precautions are classified as DANGER, WARNING, or ATTENTION in order to clearly specify the level of danger and possible injury or damage that may occur if the device is misused.

Classifications of Precautions

DANGER
Improper use of this device poses a severe and likely risk of death or serious injury.
WARNING
Improper use of this device may pose a risk of death or serious injury.
ATTENTION
Improper use of this device may result in injury or property damage*.

Symbols
This symbol shows you what you must not do.
This symbol shows you what you must do.
****This symbol shows you what you must be careful with.

Danger (regarding use and storage)


Prohibition

The following individuals should not use the device.
Use of the device could cause electronic medical devices to malfunction.

  • Do not use in conjunction with any medical electronic equipment, including pacemakers or other implanted electronic medical devices; artificial heart-lung machines or other electronic life-support medical devices, and electrocardiographs or other worn electronic medical devices.

WARNING (Use and storage)


Prohibition

  • Do not use it under the following conditions:
    Failure to comply may cause an accident or other problems.
    • If you are under a doctor’s care • If you are a child or adolescent • If you have an acute disease • If you have tuberculosis • If you have a fever • If you are suffering from hypertension • If you have an infectious disease • If you have a malignant tumor • If you have a blood disease • If you have a visceral disease • If you have a skin disease • If you have an allergic constitution • If you have atopic dermatitis • If you have skin problems • If you have sensitive skin • If you have unhealthy skin blemishes caused by physical irritation • If you are experiencing skin irritation or redness due to sunburn • If you are severely fatigued • If you are physically unwell • If you are under the influence of alcohol • If you are pregnant, menstruating, or lactating • If you take medication that induces drowsiness • If you have capillary dilatation due to long-term use of steroid hormonal drugs or a liver disorder; • If you have excessive myopia (-6D or higher). • If you have had an eye or face operation • If you have diseases of the eyes or  face or you are under treatment;

  • Do not use the device on the areas indicated below or outside of specified areas.
    Failure to comply may cause an accident or other problems.
    • Cuts • Sites where plastic surgery was performed • Anywhere inside the mouth, around the pubic region, or any mucous membrane • Acne • Sites where skin suffers from  purulent inflammation • Sites with itchiness or a hot sensation • Bulging moles • Viral warts • The Adam’s apple • Above implants • Eyeballs • The eyelids or around  the eyes

  • If you are uncertain as to whether it is safe to use the device, consult a physician prior to use.

  • Do not use it continuously in the same area. Be sure to move the device across the skin while it is in use. Do not use on areas that cannot be reached by the entire electrode head surface.
    Failure to comply may cause burn injuries.

  • Do not overuse the device.
    For usage time and frequency, follow the instructions in the User’s Manual.
    Failure to comply may cause physical injury.

  • Do not use the device continuously for an overly long period (for example, through commercial use).
    Failure to comply may cause an accident, a failure of the device, or an injury.

  • Do not use the device for a long time over sites where the skin is thin or sites above bones.
    Failure to comply may cause skin problems or physical ailments.

  • Do not use the device near a flammable substance (such as alcohol, thinner, benzene, nail polish remover, or spray).
    Doing so may cause the device to explode or catch fire.
    Exposure to water is prohibited

  • Do not use the device in the bathroom or near a bathtub, shower, sink, or other vessels filled with water.
    Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.

  • Do not splash water on the device (main body, etc.) or immerse it in water. Do not use the device in a high-humidity location or where it may be splashed with water
    Failure to comply may lead to a fire, electric shock, or malfunction.
    Non-intended uses are prohibited.

  • Do not use the device for any purpose other than those stated in the User’s Manual.
    Failure to comply may cause a failure of the device or an injury.

  • Use by unattended children or individuals with physical disabilities should be avoided. Minors should use the device only under the supervision of a guardian who has given their consent.
    Failure to comply may cause an accident or an injury.

  • Do not use the device on individuals who are unable to express their will or who have reduced skin sensitivity.
    Failure to comply may cause an accident or an injury.

  • Keep the device and AC adapter away from children and do not allow them to use either. Do not allow children to play with the device.
    Failure to comply may cause an accident or an injury.
    Dropping of the device is prohibited

  • Do not place the device in an unstable location.
    Do not drop or bump the device (either the main body or attachments).
    Failure to comply may cause a failure of the device. An injury may also be caused if the device is dropped on a foot or other exposed body part.

  • Do not place heavy items on the device, drop the device (especially during use), or otherwise subject the device to a strong impact.
    Failure to comply may cause an injury or a failure of the device.
    Disassembly is prohibited

  • Do not disassemble, attempt to repair, or modify this device in any way.
    Failure to comply may cause a fire, electric shock, or other injuries.
    Contact your local distributor for advice on repairing the device. Use is prohibited when an abnormal odor or excess heat is detected

  • If any problem occurs during use, including the presence of an abnormal odor or excess heat, stop using the device.
    Failure to comply may cause the device to become damaged or catch fire.
    Combustion warning

  • Do not leave the device in hot or humid places, such as near flames, in bright sunlight, or in a bathroom.
    Do not bring the device close to a heater.
    Failure to comply may lead to the generation of heat, a fire, or an explosion.

  • Do not place the device near fire or flames, and do not dispose of the device in a fire. Do not use, charge, or store in a high-temperature area or if the device is hot.
    The device features a built-in rechargeable battery.
    Failure to comply may lead to the generation of heat, a fire, or an explosion.

  • Be sure to check the plug configuration and the voltage of the power outlet before use.
    Failure to comply may cause the generation of heat, a fire, or a malfunction of the device.
    Explosion

  • If water or foreign matter gets into the device, immediately stop using it and request an inspection.
    Failure to comply may lead to a fire or electric shock.
    Mandatory Compliance

  • If you are currently undergoing dental treatment or have teeth fillings, choose a lower intensity level and apply the device on a different area or turn off the EMS function.
    You may feel strong irritation or discomfort by EMS on your cheeks or chin. If you feel strong discomfort, consult a physician.

  • If you sense an earthquake or see lightning, turn the power off or disconnect the AC adapter while the device is charging.
    Failure to comply may lead to a fire or electric shock.

  • Do not use or store the device in the following locations:
    Failure to comply may lead to a fire, electric shock, malfunction, failure of the device, or other accidents.
    • A high-humidity location such as a bathroom • Dusty areas • A location where there is exposure to direct sunlight • A location where water or other liquids may splash on  the device • A tilted location or a location where there is vibration or shocks • An outdoor location • A location where there are strong radio waves or magnetism •  Locations that are accessible to children • A location where there is exposure to oil smoke or steam • A location that may become hot, such as near a heating device (for  example, a heater) • A location with drastic temperature changes (for example, near an air conditioner or heater)

  • If the device is dropped or damaged, turn off the power immediately and request a repair/inspection.
    Failure to comply may lead to a fire or electric shock.

  • Do not leave the device unattended while it is turned on.
    Doing so may cause the device to catch fire or may lead to an accident.

  • Use only Level 1 upon first use and until you are accustomed to use.
    Failure to comply may cause an accident or injury.

  • When you have not used the device for a long period of time, check to see that it is functioning normally before re-starting use.
    Failure to comply may lead to an accident or malfunctions.

  • Remove all metal accessories (watches, necklaces, rings, earrings, etc.) when using the device.
    Failure to comply may cause an accident or an injury. Accessories may also become entangled in the device.

  • Do not use the device above clothes.

  • Reapply skin-care products or water during treatment to ensure that there is always some liquid between the electrode head and the skin.
    If there is an insufficient amount of skin-care products or water, the stimulation will weaken, causing skin problems.

  • If you feel an unpleasant tingling on your skin, reduce the intensity level or move to another area. Alternatively, moisturize your skin with the included skin-care products before use.
    Failure to comply may cause skin damage.

  • When using on the same area again, be sure to leave an interval of 24 or more hours between treatments.
    Excessive use may damage the skin. The above recommendations are guidelines only; please observe your skin condition and use the device accordingly.

  • After each use, remove the dirt, cosmetics, and other particles that have adhered to the device according to ‘After Treatment.’
    Failure to comply may cause a failure of the device or skin problems.

  • When cleaning the device, be sure to turn off the power, disconnect the AC adapter from the outlet, and follow the instructions in the User’s Manual.
    Failure to comply may lead to an accident or malfunctions.

WARNING (The power supply)

  • Use the AC adapter and USB cable included with this product. Plug the AC adapter directly into a wall power outlet and do not overload the electric circuit.
    Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.
    Overloading of an electric circuit is prohibited.

  • Do not damage, modify, bundle, or otherwise apply undue force to the AC adapter or USB cable.
    Failure to comply may cause the cable to break, resulting in a fire or electric shock.

Careless or reckless use is prohibited

  • Do not wrap the USB cable around the device or AC adapter when storing the device.
    Placing a load on the USB cable may cause disconnection, resulting in electric shock, or a short circuit.

  • Do not use if the AC adapter or USB cable is damaged, or if the wall socket is loose.
    Failure to comply may cause an electric shock, short circuit, fire, or failure of the device. Contact your local distributor for advice on repairing the device.
    Use of a damaged cable or plug is prohibited

  • Do not wet, wash, or immerse the AC adapter or USB charging cable in water.
    Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.
    Exposure to water is prohibited

  • When disconnecting the AC adapter from the device’s main body or the power outlet, be sure to hold the adapter at the front as you pull (do not touch the metal part).
    Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.
    Removing the plug

  • Unplug the AC adapter and USB cable when not in use.
    Do not insert or disconnect the plug with wet hands.
    Failure to comply may cause an electric shock, short circuit, or fire.
    Disconnecting the AC adapter

  • In the unlikely event that an abnormality occurs, immediately unplug the AC adapter and USB cable.
    Do not use the device if smoke, abnormal noises, or an odor is detected, or if it is otherwise operating in an abnormal state.
    Mandatory Compliance

  • Before charging the device, check to ensure the charging terminal and USB cable are not wet.
    Failure to comply may cause an electric shock, short circuit, or fire.

  • Do not pull the AC adapter or USB cable when moving or lifting the device.
    Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.

  • Be sure to use it in an operating voltage range from 100 to 240 volts.
    Be sure the AC adapter and USB cable are fully inserted into an electrical outlet.
    Failure to comply may cause a fire, electric shock, or other accident.

When Using Outside of Japan

WARNING

  • Be sure to use it in an operating voltage range from 100 to 240 volts.
    Failure to comply may cause a fire, electric shock, or a failure of the device.
    Mandatory Compliance

  • Be sure to check the plug configuration and the voltage of the power outlet before use.
    Failure to comply may cause the generation of heat, a fire, or a malfunction of the device.
    Combustion warning

  • Use a power plug adapter (not included) for outlets with shapes that differ from those in which the included power adapter plug can fit.

  • The plug configuration and voltage may vary depending on the region and the type of accommodation. Always be sure to check for compatibility before using the device.

  • For information about plug adapters, consult a travel agency or a consumer electronics retailer.

Names and Functions of Components

Main BodyYAMAN S12-1-001E ace beauty instrument - figure
1

Accessories
  • AC adapter
  • USB cable (USB Type-C™)
  • Skin-care product
  • User’s Manual

The design and specifications of the device and attached accessories are subject to change for improvement purposes without notice.

  • USB Type-C™ and USB-C™ are trademarks of the USB Implementers Forum.
Functions

Safety functions

  • Temperature sensor
    Output will be reduced automatically for safety reasons when the temperature on the skin or the electrode head rises.
    If the temperature becomes too high, the power will be turned off for safety. (When this happens, the electrode head flashes and beeps five times)
    If this happens let the device rest for about 30 minutes.

  • Motion sensor
    The motion sensor detects the movement of the device and pauses output for safety reasons when the electrode head has been used on the same area continuously.
    When the movement of the device slows, the motion sensor may reduce the level of warmth.

Auto Power Off
The device will automatically switch off approximately six minutes after it has been turned on (two short beeps).
Timer
The treatment duration on the entire face is about six minutes. The device will make one long beep after three minutes as an alert.
Charging Guide Display
When you turn the power on, the color of the lamp on the Power Button (either white or red) will indicate the remaining battery level. If the lamp lights red, recharge the battery before using the device again. The remaining battery level display will differ according to the condition of the battery and the usage environment.

Before Use

Charge the device
Using a household power outlet

YAMAN S12-1-001E ace beauty instrument - figure 2

ATTENTION

  • If there is any moisture on or around the main body or charging terminal, be sure to wipe it dry. Charging the device while it is moist could cause damage to the battery.
  • Fully charge the battery before using the device for the first time after purchasing.
  • When using the device for the first time or when the device has not been used for an extended period of time, it is possible that you will be unable to use the device for very long even with a full charge displayed. In such a case, recharge the device before using it.
  • Use only the included USB cable and AC adapter.
  • If the device is charged using an adapter with a rated power supply of DC5V2.OA or less, an error may occur. (Beeping sound: Notification of error with seven beeps)
  • In some cases, the device might not charge properly if using a generic cable or AC adapter.

Pre-testing on Skin

When using the device for the first time, always test for compatibility.

ATTENTION

  • Be sure to perform a pre-test in order to prevent skin problems from occurring.
  • If a rash, reddening, itchiness, stinging sensation, or other abnormality occurs at the pre-testing site, immediately stop the pre-test.
  • Check carefully to make sure there are no skin abnormalities before using the device. Stop using the device immediately if the treatment does not agree with your skin.
  1. Wash the inner side of your arm with soap and water, then wipe dry with a towel.
  2. Apply the included skin-care products (about one pearl-sized drop) to the center of the electrode head, turn the power on, and then use the device for about three minutes while moving it across the skin (page 13).
  3. Wash the inner side of your arm with soap and water, then wipe dry with a towel.
    Continue to use the product only if you experience no reddening or burning sensation on your skin within 24 hours.

YAMAN S12-1-001E ace beauty instrument - figure 3

How to Use

Basic method of use

  1. Turn on the device
    The Power button ( ), Level button, Level 1 lamp, and electrode head will be lit, and the radio frequency (RF) and EMS will be output.
    Personal memory function
    The device remembers the level being used and whether EMS was turned on/off when the last treatment ended and returns to the same settings the next time it is switched on.

  2. Select the level
    Each time the Level button is pressed, levels can be adjusted.
    You can check the treatment level from the level lamp.
    YAMAN S12-1-001E ace beauty instrument - figure 5 EMS on/off switch
    Press the Level button and hold down to switch EMS on/off.
    (Level button lit: EMS on; unlit: EMS off)
    ATTENTION Use only Level 1 upon first use and until you are accustomed to using it.

  3. Apply the included skin-care product to the center of the electrode head and then apply the electrode head to the skin and move it around.
    Divide the facial treatment into six areas (pages 15-16).
    Apply one pearl-sized drop of the included skin-care product to each area.
    YAMAN S12-1-001E ace beauty instrument - figure 6

  4. Care for the skin after the treatment
    After treatment is complete, rub the remaining skin-care product into the skin and then use your usual basic skin-care products to condition the skin.
    • Do not use the device on Adam’s apple, the eyelids, or around the eyes.

ATTENTION

  • Do not apply the included skin-care product with your hand. Doing so may lead the skin-care product to stick on the device or cause it to slip and fall.
  • If the device does not move smoothly, apply more of the included skin-care product.
  • Use in a position in which the entire surface of the electrode head comes in contact with your skin.
  • Be sure to move the device on your skin while using it.
  • If it feels too hot, move it a little more quickly or lower the level.

How to move the device
Move the device in the directions of the arrows in order from ① to ⑧ below. Repeat the movement three times for each arrow.

YAMAN S12-1-001E ace beauty instrument - figure 8

Left side
Approximately three minutes

  • Recommended speed for moving the device: 4 cm/second
  • Recommended duration of use: about six minutes/use (over the entire face)
  • The device will make one long beep after three minutes. Use it as a rough indicator of time used.
  • If you want to stop the treatment during use, press the Power button ( ) for at least one second to turn off the power.

YAMAN S12-1-001E ace beauty instrument - figure 10

Right side
Approximately three minutes

YAMAN S12-1-001E ace beauty instrument - figure 11

Points For Your Treatment
Use as described below for more effective results in the areas of concern.

Around the mouth
Move the device three times in the directions of the arrows below.

YAMAN S12-1-001E ace beauty instrument - figure 12

Chin and face line
Move in the directions of the arrows three times each in order from ① to ③ as shown below.YAMAN S12-1-001E ace beauty instrument - figure
13

After Treatment

How To Clean
Clean the device after each use for hygienic reasons.

WARNING

  • When cleaning the device, be sure to turn it off and disconnect the USB cable from the main body.
    Failure to comply may cause an electric shock, short circuit, or fire.

  • Do not wash the device in water.
    This device is not waterproof. Doing so may cause a failure of the device.

Wipe off any dirt using a well-wrung soft cloth or similar material.

  • For stubborn stains, wipe gently with a cloth soaked in a diluted neutral detergent.
  • Remove any skin-care products remaining between the electrode ring of the electrode head with a cotton bud or cotton pad.

ATTENTION

  • Do not leave the device with the included skin-care product on it.
  • Do not wipe the device with solvents such as alcohol, thinner, benzene, nail polish remover, kerosene, chemicals, or polishing powder.

Storage

  • Store in a clean, well-ventilated place out of the reach of children.
  • Remove the AC adapter and USB cable from the main body and the power outlet when not in use for a long period of time.
  • Do not leave the device in hot or humid places, such as near flames, in bright sunlight, or in a bathroom.

Maintenance and Inspections

  • If you have not used the device for an extended period, inspect it carefully and check that it works properly and safely before using it again.
  •  If the device is malfunctioning, go to “Troubleshooting” (page 20) and attempt to identify the problem before requesting a repair. If the problem persists, contact your local distributor, making sure that you have your purchase details at the ready when you call.
  • If the device malfunctions, appears damaged or needs service, please contact your local distributor.

Additional Information

Troubleshooting
If you perceive any abnormality while using the device, verify the following points before arranging to have it repaired.

YAMAN S12-1-001E ace beauty instrument - figure 16YAMAN S12-1-001E ace beauty instrument - figure
17

Frequently Asked Questions

Q. What is the recommended duration and frequency of use?
A. Try to use five days a week (once daily, up to six minutes).

  • Please observe your skin condition and use the device accordingly.
  • Check carefully to make sure there are no skin abnormalities before using the device. Stop using the device immediately if the treatment does not agree with your skin.

Q. Can I use the device continuously?
A.
We recommend using this device once a day, for six minutes.

Q. How much skin-care product should I use each time?
A.
Apply about six pearl-sized drops of the included skin-care product for the entire face.
It is possible to use skin-care products that you already own if they are water-soluble.
If you are using skin-care products that you already own, use the recommended usage amounts as a guide.
We recommend using gel skin-care products. If you feel that the amount of skin-care product is insufficient, add more.

Q. Can I use the device in the bathroom?
A.
This device is not waterproof. Do not use the device in the bathroom.

Q. My skin feels hot after use.
A.
This is due to the heat of the radio frequency (RF).

Q. The electrode head does not warm up.
A. The radio frequency (RF) does not warm the electrode head. Rather, it uses the power of electricity to warm your skin.

Q. Do different levels produce different effects?
A. As the levels increase, your skin is warmed more quickly and strongly. You will also feel the EMS more strongly.

  • Use only Level 1 when starting until you are accustomed to using it.

Product Specifications

Rated power supply DC5V 2.0A
Power consumption Approximately 9W (when charging)
Battery Lithium-ion battery
Charging time Approximately three hours (May vary depending on the charging

environment.)
Operating time| Approximately 40 minutes (from a fully charged state) (Operating time may vary with conditions of use and the EMS level.)
Outside dimensions| Approximately W 46 x D 47 x H 173 mm
Weight| Approximately 175 g
Materials| Main body: ABS resin and polycarbonate Electrode head: Stainless steel
Country of origin| Japan
Accessories| AC adapter———————One
USB cable (USB Type-CT”)——————— One
Skin-care products———————One
User’s Manual
Recommended environmental
temperature %.| 10 to 40°C

After-sales Service

About the skin-care product included with the device

  • Please contact your local distributor for detailed information on products and purchases.
  • Sales may be discontinued without prior notice.

Rechargeable battery

  • The rechargeable battery is a consumable item. (not covered by the product warranty)

  • If the device no longer operates for more than a short period of time even after the battery has been recharged, the battery may have reached the end of its service life
    (the battery is expected to last 300 charge cycles).

  • If you need a battery replacement, contact your local distributor.

Disposing of the device

  • Follow your local government rules for proper disposal of this product.
  • This product uses a lithium-ion battery.

Contacts for overseas customers
For countries and regions outside Japan, please contact the store where you have purchased your product for any inquiry about the product.
Alternatively, check YA-MAN Global Official Website (https://www.ya- man.com/en/)

Recommended cosmetics
Flawless Serum moisture

Quantity: 80g/200g
Item No.: CS19002/CS20001

Please contact your local distributor for detailed information on products and purchases.

  • Sales may be discontinued without prior notice.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals