RAB PORTO and PORTO XL 18 Inch 105W Neutral LED Instructions

June 8, 2024
RAB

RAB PORTO and PORTO XL 18 Inch 105W Neutral

RAB PORTO and PORTO XL 18 Inch 105W Neutral

INSTRUCTIONS

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNING : Make certain power is OFF before installing or maintaining fixture. No user-serviceable parts inside..

CAUTION : For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly. Apply weatherproof silicone sealant around the edge of the ceiling mounting box and/or junction box. This is especially important with an uneven ceiling surface. Silicone all plugs and unused conduit entries.

CEILING MOUNTING

  • Loosen Screws (2) to free Junction Box from LED Housing.
  • Remove NPS Adaptor as marked if mounting directly to ceiling surface without junction box.
  • Mount Junction Box to ceiling by knocking out (4) Knock Out
  • Locations as marked in Fig. 3. Use the appropriate mounting hardware for the mounting surface.
  • May alternately be mounted to recessed junction boxes.
  • For hands-free wiring, hang the fixture on the EZ Hang Hook
  • Connect supply wires to Fixture Wires.
  • Supply can come from back or through either of four 1/2” Plugs to make electrical splices.
  • Use appropriate UL approved wire connectors as required by code to complete wiring.
  • Close fixture and tighten Screws (2).
  • If mounting surface is irregular, use caulk to seal any gaps around Junction Box.

PENDANT MOUNTING

  • Feed supply wires through Pendant (supplied by others)
  • Loosen Screws (2) on LED Housing.
  • Remove 1/2” plug and mount Junction Box to Pendant. For 3/4”
  • Pendant, remove plug and NPS Adaptor. Hang LED fixture with EZ Hang Hook as shown in Fig. 1
  • Make supply connections wiring sections as shown in Ceiling Mounting section above.
  • Close fixture and tighten Screws (2).

KNOCK OUT LOCATIONS

ON-OFF WIRING

  • Connect the black fixture lead to the LINE supply lead.
  • Connect the white fixture lead to the COMMON supply lead.
  • Connect the GROUND wire from fixture to supply ground.

0-10V DIMMABLE WIRING

  • Connect the black fixture lead to the LINE supply lead.
  • Connect the white fixture lead to the COMMON supply lead.
  • Connect the GROUND wire from fixture to supply ground.
  • Do NOT connect the GROUND of the dimming fixture to the output.
  • Connect the purple fixture lead to the (V+) DIM lead.
  • Connect the pink (or gray) fixture lead to the (V-) DIM lead.
  • Cap the yellow fixture lead, if present. Do NOT connect.

TROUBLESHOOTING

  • Check that the line voltage at the fixture is correct.
  • Refer to wiring directions.
  • Be sure the fixture is grounded properly.
  • Is the photocell, if used, functioning properly?

CLEANING & MAINTENANCE

  • Clean polycarbonate lens with non-abrasive cleaning solution.
  • Do not open the fixture to clean the LEDs. Do not touch the LEDs.

18745 BILEVEL SENSOR FOR D10

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com

FSIR-100 (RAB CAT#WSREM) REMOTE

CUSTOMIZATION

  • Auto calculates appropriate Setpoint based on surrounding light: 2 minute warm-up, blinks on/off 8 times, then turns off until motion is detected
  • High Mode: 0-10V with 0.2V increments
  • Low Mode: 0-9.8V with 0.2V increments
  • Time Delay: 30 seconds, 1-30 minutes
  • Cut-off: 1-59 minutes, 1-5 hours, DIS (disabled)
  • Setpoint: 1-250 fc, AUTO, DIS (disabled)
  • Sensitivity: NONE, LOW, MED, MAX
  • Ramp-up Time: 1-60 seconds
  • Fade-down Time: 1-60 seconds

ACCESSORIES

  • WSREM remote
  • WSLENS-8: 48’ diameter coverage from 8’ height
  •  WSLENS-20: 40’ diameter coverage from 20’ height
  • WSLENS-40: 60’ diameter coverage from 40’ height
  • WSLENS-40W: 100’ diameter coverage from 40’ height

OPERATION (NON-DIMMABLE DRIVER)

  • Ambient light above the Setpoint causes sensor to keep fixture light off, despite detected motion
  • Light turns on with motion detection
  • Light turns off with lack of motion after reaching the Time Delay period

TROUBLESHOOTING ON FACTORY SETTINGS (WITHOUT REMOTE)

  • Check fixture mounting and compare fixture location and sensor coverage with the coverage diagrams
  • Check that movement is not directly toward sensor pattern, but across the pattern
  • Adjust fixture location as necessary
  • Check that far away movement directly towards sensor is not entirely within one Detection Pattern Finger (see coverage pattern diagrams on the next page)
  • Adjust sensitivity to maximum for best results with

TROUBLESHOOTING WITH REMOTE

Check current sensor settings by:

  • Select FSP-211 on the main screen after powerup
  • Select Current Settings in the menu
  • Point remote at sensor, press center button and release
  • Be sure that sensor blinks and fixture lights, confirming connection with remote
  • Current settings will be shown on remote screen
  • Fixture will not light/sensor does not detect motion:
  • Using increments of 1 fc, adjust Setpoint to a larger value until fixture lights with motion, and/or raise Sensitivity
  • Fixture and sensor are too active: Using increments of 1 fc, adjust Setpoint to a lower value until fixture only lights at desired intervals/motions, and/or lower Sensitivity
  • Fixture lights at installation and follows expected pattern, but does not turn on with subsequent detected motion: See 2 and 3 above to adjust Setpoint or change Setpoint to Auto

COVERAGE DIAGRAMS

SENSOR TOP COVERAGE DIAGRAMSRAB PORTO and PORTO XL 18 Inch 105W Neutral
7

SENSOR SIDE COVERAGE DIAGRAMS

DIMMABLE WIRING DIAGRAM

Easy Installation & Product Help

  • Tech Help Line
    • Call our experts 888 RAB-1000
  • Visit our website for product info
  • email

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals