Metalux 4NWS3C3MS-UNV Cooper Lighting Solutions Instruction Manual

June 8, 2024
METALUX

Metalux 4NWS3C3MS-UNV Cooper Lighting Solutions

PACKAGING CONTENTS

A. Fixture housing

B. Len

C. (2) 8-32 x 25 mm #8-32 machine screws

D. (3) Wire connectors

INSTRUCTIONS FOR SELECTING CCT & LUMEN (Only for CCT and Lumen select

options

  1. Two slide switches are located on the driver enclosure: one for CCT and the other for lumen. CCT and lumen options must be selected before installation.
  2. To select the CCT, slide the first switch to the desired LED color temperature (3500K, 4000K, 5000K CCT).
  3. To select the lumen, slide the second switch to the desired lumen
ITEMS REQUIRED

(Purchase separately)

  • Phillips screwdriver
  • Flat head screwdriver
  • Pliers
  • Safety glasses
  • Ladder
  • Hammer

Note: This product is not intended for continuous row applications. Suspension kits sold separately

WARNINGS AND CAUTIONS

Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product must be performed by a qualified electrician. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazards involved. The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any maintenance. Disconnect power at fuse or circuit breaker.

Risk of Fire- Minimum 90°C supply conductors.

Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.

Risk of Personal Injury- Due to sharp edges, handle with care.
Failure to comply with these instructions may result in death, serious bodily injury and property damage

DISCLAIMER OF LIABILITY : Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling or use of this product.
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
NOTICE: Ground screw provided in proper location. Do not relocate.
NOTICE: Fixture may become damaged and/or unstable if not installed properly.
Note: Specifications and dimensions subject to change without notice.

ATTENTION Receiving Department: Note actual fixture description of any shortage or noticeable damage on delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be filed within 15 days of delivery. All damaged material, complete with original packing must be retained.

WIRING DIAGRAM

INSTALLATION INSTRUCTIONS

  1. Turn off power at main fuse/breaker box. Carefully open carton, remove fixture from carton.

  2. Remove lens using a flat head screwdriver inserted along edge of fixture. Push up on screwdriver to release lens from fixture housing. (Fig. 1)

  3. Determine if you wish to mount the luminaire onto the J-box or mount the fixture directly to the surface or wall. If mounting luminaire to J-box, go to step 8.

  4. Using the luminaire as a template, place fixture over the J-box and mark each surface mount hole position in the ceiling (Fig. 2).

    Set aside the luminaire in a safe place. Drill a hole over each marked hole position. Insert anchor bolt (not included) into each hole. For proper hole size, refer to anchor bolt instruction.

  5. Screw the four mounting screws into each anchor bolt.

  6. Locate wires in J-box. Connect all fixture wires to power supply wires: White to white, black to black, and green to green with wire nuts (Fig. 3).

    See wiring diagram for reference.

  7. After making all wire connections, push all wires and wire nuts inside J-box (Fig. 4).

    Install luminaire onto mounting screws by inserting screws through fixture key slots. Once secure, tighten screws.
    Note: Be sure no electrical wires are pinched between surface and luminaire. If so, loosen screws and readjust wiring.

  8.  If mounting luminaire directly onto J-box, make Connections as per step 6 and align fixture mounting slots with J-Box mounting holes. Use mounting screws (C) to secure fixture to J-Box (Fig. 5).

    Note: Ensure that once installed to J-Box, no visible gaps appear between ceiling surface, J-box and luminaire housing

  9. Attach lens by aligning lens groove with edge of channel. Insert one side of lens then press opposite side of lens until it snaps into place. Ensure lens groove is secured along entire length of the lens on both sides (Fig. 6).

    Remove protective film from lens.

  10. Turn breaker back on to verify light fixture turns on and lumen output (brightness) and LED CCT color temperature is acceptable. If circuit is attached to a switch, be sure to turn on switch to energize fixture. (See page 1)

IMMING INSTALLATION INSTRUCTIONS

For a fixture containing (1) 120-347V Driver.

  • Combine the positive lead from the dimmer with the positive lead (purple) connected to the dimming port (DIM +) of the driver.
  • Combine the negative lead from the dimmer with the negative lead (pink) connected to the dimming port (DIM -) of the driver.

For the 0-10V dimming switch.

  • Wire per 0-10V manufacturer’s dimmer instructions. See www.cooperlighting.com for a listing of dimmers that are compatible with the NWS Wrap series product.
SUSPENSION INSTRUCTIONS
  • Product can be suspended. For a list of manufacturer suspension options that are compatible with the NWS Wrap series product visit www.cooperlighting.com.
5-YEAR LIMITED WARRANTY

THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Cooper Lighting Solutions warrants to customers that, for a period of five years from the date of purchase, Cooper Lighting Solutions products will be free from defects in materials and workmanship. The obligation of Cooper Lighting Solutions under this warranty is expressly limited to the provision of replacement products. This warranty is extended only to the original purchaser of the product. A purchaser’s receipt or other proof of date of original purchase acceptable to Cooper Lighting Solutions. This is required before warranty performance shall be rendered. This warranty does not apply to Cooper Lighting Solutions products that have been altered, repaired or that has been subjected to neglect, abuse, misuse or accident (including shipping damages). This warranty does not apply to products not manufactured by Cooper Lighting Solutions which have been supplied, installed, and/or used in conjunction with Cooper Lighting Solutions products. Damage to the product caused by replacement bulbs or corrosion or discoloration of brass components are not covered by this warranty. LIMITATION OF LIABILITY: IN NO EVENT SHALL COOPER LIGHTING SOLUTIONS BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL THE LIABILITY OF COPPER LIGHTING SOLUTIONS FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR MODIFICATION OF COOPER LIGHTING SOLUTIONS PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE, EXCEED THE PURCHASE PRICE OF COOPER LIGHTING SOLUTIONS PRODUCTS GIVING RISE TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES.
To obtain warranty service, please contact Cooper Lighting Solutions, at 1-800 334-6871, press option 2 for Customer Service, or via e-mail [email protected] and include the following information:

  • Name, address and telephone number
  • Date and place of purchase
  • Catalog and quantity purchase
  • Detailed description of problem

All returned products must be accompanied by a Return Goods Authorization Number issued by the Company and must be returned freight prepaid. Any product received without a Return Goods Authorization Number from the Company will be refused. Cooper Lighting Solutions is not responsible for merchandise damaged in transit. Repaired or replaced products shall be subject to the terms of this warranty and are inspected when packed. Evident or concealed damage that is made in transit should be reported at once to the carrier making the delivery and a claim filed with them. Reproductions of this document without prior written approval of Cooper Lighting Solutions are strictly prohibited.

For assistance, call 1-800-334-6871 or e-mail us at [email protected] Printed in China

IC warning:

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.

FCC warning:

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

1121 Highway 74 South, Peachtree City, GA 30269
www.cooperlighting.com
© 2022 Cooper Lighting Solutions

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

METALUX User Manuals

Related Manuals