Metalux Accord 22AC LED Troffer User Manual
- June 8, 2024
- METALUX
Table of Contents
- Accord 22AC LED Troffer
- Product Specifications
- Product Features
- Dimensional and Mounting Details
- Order Information
- Lumen Outputs
- Voltage Options
- CCT and Driver Options
- Product Usage Instructions
- Installation Steps:
- Maintenance Tips:
- Troubleshooting:
- Q: Can this troffer be used in damp locations?
- Q: How do I choose the right lumen output for my space?
- Q: Are there specific voltage requirements for emergency
Accord 22AC LED Troffer
Product Specifications
- Brand: Metalux
- Model: Accord 22AC LED
- Size: 2′ x 2′
- Type: Specification Grade LED Troffer
- Features: WaveLinx LITE, WaveLinx PRO
Product Features
Designed to provide safe and convenient means of disconnecting
power.
Dimensional and Mounting Details
Access Plate: Included
Ceiling Compatibility: G Grid/Lay-in Standard, F Drywall Frame
Kit
Ceiling Type Compatibility: Exposed Grid, Concealed T Slot Grid,
Flange
Trim Type: G or T
Order Information
SAMPLE ORDER NUMBER: 22AC-LD5-34-UNV-L835-CD1-U
Lumen Outputs
Stock Lumen Outputs: 2300 Lumens, 3400 Lumens
MTO Lumen Outputs: 2000 Lumens, 2700 Lumens, 3800 Lumens, 4400
Lumens
Voltage Options
Universal Voltage: 120-277V
347V Option: Available for specific configurations
Emergency Options: Various wattage emergency battery packs
available
CCT and Driver Options
CCT Options: 3000K, 3500K, 4000K
Driver Types: 0-10V Dimming, Sensor-ready Dimming, DALI Driver,
Step Dimming Driver, Lutron HiLume, Lutron 5 Series
Product Usage Instructions
Installation Steps:
-
Locate suitable ceiling grid or drywall frame for
installation. -
Ensure power source is turned off before proceeding.
-
Mount the troffer securely according to dimensional and
mounting details provided. -
Connect power supply following the specified voltage
requirements. -
If applicable, configure dimming options based on driver
type.
Maintenance Tips:
-
Regularly clean the troffer to ensure optimal light
output. -
Check for any loose connections or damage to the fixture.
-
Replace emergency batteries as per manufacturer
recommendations.
Troubleshooting:
-
If the troffer does not turn on, check power supply and
connections. -
If experiencing flickering lights, adjust dimming settings or
replace the driver if needed. -
Contact customer support for further assistance if issues
persist.
Frequently Asked Questions (FAQ)
Q: Can this troffer be used in damp locations?
A: The Air versions are not designed for continuous row mount
applications and may not be suitable for damp locations.
Q: How do I choose the right lumen output for my space?
A: Consider the size of the area to be illuminated and desired
brightness levels to select the appropriate lumen output
option.
Q: Are there specific voltage requirements for emergency
options?
A: Yes, emergency battery pack options come with specific
voltage ranges to ensure proper functionality during power
outages.
Project Prepared by
Catalog # Notes
Type Date
Metalux
Accord 22AC LED
2′ x 2′ Specification Grade LED Troffer
Typical Applications Office · Education · Healthcare · Retail
Interactive Menu
· Order Information page 2 · Photometric Data page 3 · Control Solutions page
4 · Product Warranty
Product Certification
Product Features
WaveLinx LITE
WaveLinx PRO
Designed to provide safe and convenient means of disconnecting power
Top Product Features
· Available in 1′ x 4′, 2′ x 2′ and 2′ x 4′ recessed & surface versions ·
Advanced optical control · High performance efficacy up to 127 lumens per watt
· Over 60% energy savings when compared to fluorescent troffers · Three CCT
options: 3000K, 3500K and 4000K at 85 CRI · Options to meet Buy American and
other domestic preference requirements
Dimensional and Mounting Details
Access Plate
23-3/4″ [603mm]
Ceiling Compatibility
G Grid/Lay-in Standard
F Drywall Frame Kit
Ceiling Type**
Exposed Grid Concealed T Slot Grid Flange
Trim Type
G G or T G or T ***
3-1/4″ [83mm]
23-3/4″ [603mm]
1-1/2″ [39mm]
3-3/8″ [86mm]
3-1/16″ [78mm]
24″ [610mm]
NOTE: 2′ x 2′ and 2′ x 4′ allow for row mounting
3-1/4″ [83mm]
11-3/4″ [298mm] 23-3/4″ [603mm]
PS519360EN page 1
April 18, 2024 2:50 PM
Order Information
SAMPLE ORDER NUMBER: 22AC-LD5-34-UNV-L835-CD1-U
Accord 22AC LED 2′ x 2′
Domestic Preferences
Rating
Series
Type
Lamp Type
Lumen Outputs
Shielding
Voltage
Domestic Preferences (1)
[Blank]=Standard BAA=Buy American Act TAA=Trade Agreements Act
Rating
[Blank]=Standard ATW-SW4= Chicago Rated
Notes
(1) Only product configurations with these designated prefixes are built to be
compliant with the Buy American Act of 1933 (BAA) or Trade Agreements Act of
1979 (TAA), respectively. Please refer to DOMESTIC PREFERENCES website for
more information. Components shipped separately may be separately analyzed
under domestic preference requirements.
Series (2) 22AC=2×2 Accord Series
Type
[Blank]=Standard A=Air (vented) (3)
Lamp Type LD5=LED 5.0
Notes
(2) DesignLights Consortium® Qualified and classified for both DLC Standard
and DLC Premium, refer to www.designlights.org for details.
Notes
(3) Air versions are not designed for continuous row mount applications. Air
version is vented but does not meet air handling requirements.
Lumen Outputs
Stock Lumen Outputs 23=2300 Lumens (4) 34=3400 Lumens
MTO Lumen Outputs 20=2000 Lumens (4) 27=2700 Lumens 38=3800 Lumens 44=4400 Lumens
Notes
(4) 2000 and 2300 lumen options are not available with Step-dim driver.
Shielding
Voltage (5)
[Blank]=Standard Lens
UNV=Universal Voltage 120-277 347V=347 Volt (6) 120V=120 Volt (7) 277V=277 Volt (7)
Notes
(5) Products also available in nonUS voltages and frequencies for
international markets. (6) 347V emergency option not available with emergency
options. (7) Must specify voltage as 120V or 277V when ordering GTR2 option.
Emergency Options
CCT
Flex
Driver Type
Emergency Options
EL7W=7-watt 120V-277V emergency battery pack (8) EL10W=10-watt 120V-277V
emergency battery pack (8) EL14W=14-watt 120V-277V emergency battery pack (8)
EL10WSD=10W emergency battery pack with self-diagnostic installed (8), (1O)
EL14WSD=14W emergency battery pack with self-diagnostic installed (8), (10)
ETRD= 120-277V Emergency Transfer Relay with dimming control (9)
CCT
L830=3000K L835=3500K L840=4000K
Flex
A3/8-4/18GDIM=3/8″ Flex with 0-10V Dimming Leads See below for details.
A3/8-5/18GDIM=Flex with 0-10V Dimming leads and Blue for alternate wiring. See
below for details.
Driver Type
CD=0-10V Dimming Driver (1%-100% Dimming) SR=Sensor-ready Dimming Driver
(1%-100% Dimming) 5LTD=Fifth Light DALI Driver (10%-100% Dimming) (11), (B)
5LTHD=Fifth Light Dimming Driver (1%-100% Dimming) (B) SD=Step Dimming Driver
(50%-100% Dimming) (12) LH=Lutron HiLume (LDE1 series) 1%-100% EcoSystem
Driver with Soft-on Fade to Black dimming (D) L5=Lutron 5 Series (LDE5-Series)
5%-100% EcoSystem Driver (D)
Notes
(8) Factory installed with integral test switch/indicator/laser test. For
approximate delivered lumens multiply the lumens per watt of the desired
fixture by the wattage of the emergency battery pack (100 lm/W x 7=700
lumens). IESformat photometry for luminaire under emergency operation
available. Battery option increases total height by 1 inch. (9) Used to bypass
local control during outage. Must be used in conjunction with UL 1008 device
(provided by others). ETRD option only requires one relay when used on a
dimming fixture. (10) EL10WSD and EL14WSD not available with 347V.
Flexible Metal Conduit Options
Flex options available for 0-10V dimming control, DALI dimming control,
emergency and night light functions. 72-inch factory-installed and pre-wired
to driver, fitted to luminaire housing access plate with 90° enclosed FMC
connector. Not all options may be combined and installation ratings vary by
type.
A3/8-4/18GDIM series notes: Factory installed dimming option 3/8″ flexible
metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed
0-10V +/control wires. Meets UL 66, 83, 1479, 1569, 1581, 2556. NEC® 250.118,
300.22(C), 392, 396, 330, 501, 502, 503, 530, 504, 505, 518, 520, 530, 645,
72; Federal Specification A-A-59544 (formerly J-C-30B); all applicable OSHA
and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration
with applicable fire stop product (not included). May be surface mounted,
fished and/or embedded in plaster. Cable tray and approved raceway rated,
install per NEC®; Environmental Air-Handling Space Installation per NEC®
300.22(C).
Notes
(11) 2000, 2300, 2700 and 3400 lumen options are not available with a Fifth
Light “5LTD” and “5LTHD” driver. (12) 22000 and 2300 lumen options are not
available with Step-dim driver.
Integrated options must be used in conjunction with the associated system and
may not be compatible with other options or accessories. Please refer to the
following: (B) Consult Fifth Light system pages for additional details and
compatibility. (D) Consult Marketplace Options – Lutron system pages for
additional details and compatibility. Compatible only with driver series
shown, and may require two or more drivers. Requires field commissioning to
operate or dim. Contact Lutron at www.lutron.com.
Number of Drivers
Integrated Sensing Systems
Number of Drivers 1=1 Driver
Integrated Sensing Systems
[Blank]=No Sensor WPS (formerly WAA)=WaveLinx PRO Wireless Sensor, Occupancy
w/ photocell, Networked (A)
Packaging
Packaging U=Unit Pack PALC=Job Pack, in carton
Notes
Integrated options must be used in conjunction with the associated system and
may not be compatible with other options or accessories. Please refer to the
following: (A) Consult WaveLinx system pages for additional details and
compatibility.
Accessories
Accessories (order separately) (13)
T3A END E.Q. BRACKET PARTS BAG DF-22W-U=2′ x 2′ Drywall Frame Kit SK-22-WS=2′
x 2′ Shallow Surface Mount Kit SK-22-WT=2′ x 2′ Tall Surface Mount Kit
Notes (13) Accessories sold separately will be separately analyzed under
domestic preference requirements. Consult factory for further information.
PS519360EN page 2
April 18, 2024 2:50 PM
Accord 22AC LED 2′ x 2′
Product Specifications
Construction · Shallow 3-1/4″ deep housing is die-formed of code
gauge, prime cold rolled steel · Heavy gauge endplates are securely attached
with
screws for strength and rigidity and the elimination of gaps · End plates have
integral grid-lock feature for safety and convenience · Four auxiliary fixture
end suspension points provided · Large access plate for supply connection ·
Driver can be accessed from below without tools.
Integrated Controls · 0-10V dimming to 1% standard · Integrated WaveLinx
options provide wireless
individual fixture control and enable code compliance, increased energy
savings, grouping of fixtures, and connection to WaveLinx control systems ·
DALI 2.0, Lutron, and step-dimming available
Photometric Data
Electrical · LED’s available in 3000K, 3500K or 4000K with a
minimum CRI of 80 · Color accuracy 3-Step MacAdam ellipse (SDCM) · Projected
life is 60,000 hours at 89% lumen output · Electronic drivers available for
120-277V and 347V
applications
Emergency Battery Options · 120V-277V integral emergency battery pack comes
in 7-watts, 10-watt, or 14-watts · Self-diagnostic emergency battery available
in 10 or
14-watts (NFPA 101® Life Safety Code®) · Constant power to the LED system for
controlled,
predictable discharge · Integrated test switch/indicator light visible from
floor · Min. 90-minute backup period for code compliance · Integral emergency
transfer relay available for
generator equipped power systems
Finish · Multistage, iron phosphate pretreatment ensure
maximum bonding and rust inhibition
· White enamel finish
Reflectors · High reflectance baked matte white enamel finish
for luminous uniformity
Shielding · Positively retained frosted acrylic profile lenses
provide a soft but effective distribution of light
Compliance · Modules are UL recognized components · Indoor luminaires are
cULus listed for 25ºC ambient
environments · Complies with IESNA LM-79 · LEDs compliant with LM-80 standards
· DesignLights Consortium® Qualified and classified
for both DLC Standard and DLC Premium, refer to www.designlights.org for
details.
Limited Warranty · Five-year limited warranty standard. Optional ten
year limited warranty available.
View IES files
213
427
640
853 0°
10° 20°
90° 80° 70° 60° 50°
40° 30°
22AC-LD5-23-UNVL835-CD1-U Electronic Driver Linear LED 3500K Spacing criterion: (II) 1.18 x mounting height, () 1.31 x mounting height Lumens: 2392 Input Watts: 19.5W Efficacy: 122.7 LPW Test Report: 22AC- LD5-23-UNVL835-CD1-U.IES
309
618 927
1236 0°
10° 20°
90° 80° 70° 60° 50°
40° 30°
22AC-LD5-34-UNVL835-CD1-U Electronic Driver Linear LED 3500K Spacing criterion: (II) 1.18 x mounting height, () 1.31 x mounting height Lumens: 3466 Input Watts: 30.2W Efficacy: 114.8 LPW Test Report: 22AC- LD5-34-UNVL835-CD1-U.IES
Energy and Performance Data
Stock or MTO MTO MTO MTO MTO Stock Stock MTO MTO MTO MTO Stock Stock MTO MTO MTO MTO MTO MTO
Catalog Logic (Curved)
22AC-LD5-20-UNV-L830-CD1-U 22AC-LD5-20-UNV-L835-CD1-U 22AC-
LD5-20-UNV-L840-CD1-U 22AC-LD5-23-UNV-L830-CD1-U 22AC-LD5-23-UNV-L835-CD1-U
22AC-LD5-23-UNV-L840-CD1-U 22AC-LD5-27-UNV-L830-CD1-U 22AC-
LD5-27-UNV-L835-CD1-U 22AC-LD5-27-UNV-L840-CD1-U 22AC-LD5-34-UNV-L830-CD1-U
22AC-LD5-34-UNV-L835-CD1-U 22AC-LD5-34-UNV-L840-CD1-U 22AC-
LD5-38-UNV-L830-CD1-U 22AC-LD5-38-UNV-L835-CD1-U 22AC-LD5-38-UNV-L840-CD1-U
22AC-LD5-44-UNV-L830-CD1-U 22AC-LD5-44-UNV-L835-CD1-U 22AC-
LD5-44-UNV-L840-CD1-U
Delivered Lumens
1997 2076 2118 2301 2392 2440 2599 2702 2756 3334 3466 3535 3681 3827 3904
4270 4439 4528
Watts
16.7 16.7 16.7 19.5 19.5 19.5 22.4 22.4 22.4 30.2 30.2 30.2 34.3 34.3 34.3
42.3 42.3 42.3
Efficacy (LPW)
119 124 127 118 123 125 116 121 123 110 115 117 107 112 114 101 105 107
Lumen Maintenance
Ambient Temperature
TM-21 Lumen Maintenance (60,000 hours) (1)
Theoretical L70
(Hours) (2)
25ºC
89%
178,000
Notes: (1) Supported by IES TM-21 standards. (2) Theoretical values represent estimations commonly used; however, refer to the IES position on LED Product Lifetime Prediction, IES PS-10-18, that explains proper use of IES TM-21 and LM-80.
Shipping Data Catalog No. 22AC-LD5-23 22AC-LD5-34
Wt. 14 lbs. 14 lbs.
PS519360EN page 3
April 18, 2024 2:50 PM
Accord 22AC LED 2′ x 2′
Control Solutions
· WaveLinx LITE wireless · WaveLinx PRO wireless · WaveLinx CAT wired ·
WaveLinx Wired
Integrated Sensor Coverage Pattern
TOP VIEW:
CL
4.5m (15FT)
SIDE VIEW:
0m (0ft) 4.5m (15FT)
0m (0ft)
CL
2.4m (8ft)
3.0m (10ft)
4.5m (15FT)
4.5m (15FT)
2.25m
0m
(7.5FT) (0ft)
The Accord LED with WaveLinx offers no-hassle lighting control with multiple luminaire level control solutions.
WaveLinx PRO
WaveLinx PRO is a wireless lighting control solution, for connected spaces, that significantly reduces a building’s energy consumption. From a single floor to an entire campus, WaveLinx PRO connects more than lighting assets; it shares aggregated sensor data with the WaveLinx CORE platform and other building systems, so building owners can improve operations, spaces environment, and tenants’ experience. WaveLinx PRO offers a rich portfolio of wireless devices, WaveLinx PRO-enabled luminaires, and an intuitive WaveLinx mobile app for office, education, warehouse, and parking garage applications.
WaveLinx LITE
WaveLinx LITE is a cost effective, wireless digital lighting control solution, with out-of-the-box functionality, that saves energy and meets code. It’s designed for applications that require occupancy-based, daylighting, or manual light control. Customize installations for office, education, warehouse and parking garages using the secure, simple mobile app.
With Integrated WaveLinx Sensor
With Integrated WaveLinx Node
Add a hidden WaveLinx sensor node (WPN, WLN) to your space lighting design!
2.25m (7.5ft)
4.5m (15ft)
Allows to:
· Keeps luminaire aesthetics
· Connect fixtures without the realestate to include sensor option such as
downlights
· Connect sealed fixtures without a standard sensor option such as products
for clinical space.
Note: Installation of integrated sensors within 3-ft (1m) of HVAC air vents is not recommended. The pattern shown is intended solely as a general guide and is not to scale.
Option
Integrated Controls Options
Luminaire Level Automatic
Out of the Box Lighting Control Dimming
Functionality
(LLLC)
Photocell
Occupancy Sensing
CCT Control
WLS
X
X
X
X
WLN
X
WPS
X
X
X
X
WPN
X
X
Systems comparison chart
Cooper Lighting Solutions provides many lighting system solutions designed to
satisfy code requirements and meet the unique needs of any project.
Note: WaveLinx utilizes scenes to allow users to change an area’s fixtures Correlated Color Temperature (CCT) and intensity using commissioned manual wireless wallstation scene control. To enable CCT adjustments through WaveLinx, include WPS or WPN devices in addition to VividTune or BioUp technologies for integrated fixture control.
Luminaire with standalone sensor
Occupancy
Yes
Daylighting
Yes
Wallstations
Gateways
Devices (MAX)
Software
Areas
Zones
Scheduling
VividTuneTM
Plug-Load Control
Low-Voltage Power
Integration
Dashboards
Configuration
Standalone Spaces
WaveLinx LITE
Yes Yes Yes 40 per Area (1120 per space) WaveLinx LITE Mobile App 28 per
Space 16 per Area Yes Installer
Standalone Spaces
WaveLinx CAT
Yes Yes Yes 40 per Area WaveLinx CAT Mobile App Unlimited 16 per Area
Yes Yes Installer
Networked Spaces
WaveLinx PRO
Yes Yes Yes 1 WAC 200 per WAC2 WaveLinx Mobile App 50 per WAC2 16 per Area
Local Yes Yes Yes Technician
Enterprise WaveLinx
CORE
Yes Yes Yes 300 WACs 32,500 per CORE Enterprise CORE up to 3,000 up to 9,000
Global Yes Yes Yes BACnet, API Energy, Occupancy Technician / IT
Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com
© 2024 Cooper Lighting Solutions All Rights Reserved.
Specifications and dimensions subject to change without notice.
PS519360EN page 4
April 18, 2024 2:50 PM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>