BEFORE START-UP

Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide!
Operate the device only with a professionally installed power supply at a nearby  power socket that is freely accessible at all times.

Please observe the following when setting up the device

  • The power plug of the device must be freely accessible.
  • For devices to be operated on the desktop, please attach the adhesive rubber footpads
  • Do not rest any objects on top of the device
  • Keep all ventilation slots on the side of the device clear of obstruction
  • Mount the device into a 19” unit in a server cabinet using the provided screws and mounting brackets. Pay attention to the “R” and “L” marks on the brackets for accurate mounting.
    Please note that support service for third-party accessories is excluded.

CONTROL PANEL

CONTROL PANEL

  1. **G.FAST- / VDSL- / ADSL interfaces***
    If required, use the supplied DSL cables for the IP-based line to connect each G.FAST / VDSL / ADSL interface to a separate provider’s telephone socket. For more information, please contact your Internet service provider.
  • Please use the appropriate cables depending on the design

    1. WAN 1 interfaces (SFP / TP combo port)
      Insert a suitable SFP module (e.g. 1000Base-SX or 1000Base-LX) into the SFP port. Choose a cable compatible with the SFP module and connect it as described in the module’s documentation. SFP modulel and cable are not included.
      If desired, alternatively connect the WAN 1 TP interface to a WAN modem using an ethernet cable.

    2. WAN 2 interface (TP)
      Connect the WAN 2 interface to a WAN modem using an Ethernet cable.

    3. Ethernet interface
      Use the cable with the kiwi-colored connectors to connect one of the interfaces ETH 1 to ETH 4 to your PC or a LAN switch.

    4. Analog interfaces
      Connect analog terminal devices to the analog interfaces either directly via RJ11 or with the help of the enclosed TAE adapters.

    5. ISDN interfaces
      ISDN 1: Internal (NT) ISDN bus.
      ISDN 2: Internal (NT) ISDN-bus.
      A 100-Ohm resistor for line termination is switchable in LCOS.

    6. Configuration interface
      Use the included serial configuration cable to connect the serial interface (COM) to the serial interface of the device you want to use for configuring / monitoring.

    7. USB interface
      You can use the USB interface to connect a USB printer or a USB storage device.

    8. Power connector and grounding point(device back side)
      Supply power to the device via the power connector.
      Please use the IEC power cable supplied (separately available for WW devices).

      ATTENTION:
      High touch current possible! Connect to earth before connecting the power supply

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS

  1. VoIP / VPN / POWER
    VoIP| –
    ---|---
    Off| No SIP accounts defined or VCM is off
    Green, permanently| All defined and active SIP accounts (outgoing) were successfully registered
    Red, permanently| Not all of the defined and active SIP accounts were registered (possibly still in process)
    Red or green, inverse flashing| Number of currently used lines (connecting or connected)
    VPN| –
    ---|---
    Off| VPN connection inactive
    Green, permanently| VPN connection active
    Green, flashing| VPN connecting
    POWER| –
    ---|---
    Off| Device switched off
    Green, permanently| Device operational, resp. device paired / claimed and LANCOM Management Cloud (LMC) accessible
    Green / red, blinking| No password set. Without a password the configuration data in the device is unprotected.
    Red, blinking| Charge or time limit reached
    1x green inverse blinking
    | Connection to the LMC active, pairing OK, device not claimed
    2x green inverse blinking| Pairing error, resp. LMC activation code not available
    3x green inverse blinking
    | LMC not accessible, resp. communication error
  2. RESET
    Reset button| short press > Restart the device long press > Reset the device
    ---|---
  3. G.FAST / VDSL 1 / VDSL 2
Off Interface deactivated
Green, blinking DSL connecting
Green, permanently DSL connection active
Green, flickering DSL data transfer
Green / orange, flickering DSL transfer error
Green / orange, blinking synchronously DSL hardware error
Orange, blinking DSL training
Orange, permanently DSL sync
  1. WAN 1 / WAN 2
    Green, orange off| No networking device connected
    ---|---
    Green, permanently| Connection to network device operational, no data transmission
    Green, flickering| Data transmission
    Orange off| 1000 Mbps
    Orange, permanently|  10 / 100 Mbps
  2. ETH 1 – ETH 4
    Green, orange off| No networking device connected
    ---|---
    Green, permanently| Connection to network device operational, no data traffic
    Green, flickering| Data transmission
    Orange off| 1000 Mbps
    Orange, permanently| 10 / 100 Mbps
  3. ISDN 1 (NT) / ISDN 2 (NT)
    Off| Interface deactivated
    ---|---
    Green, permanently| D-channel active
    Green, blinking| ISDN connection active
    Orange, blinking| ISDN connecting
    Green / orange, blinking synchronously| ISDN hardware error
    Orange, permanently| Connection inactive

Hardware

Power supply Internal power supply unit (100–240 V, 50-60 Hz)
Power consumption Max. 34 W
Environment Temperature range 0–40 °C, humidity 0–95 %; non-condensing
Housing Robust metal housing, 1 HU with mounting brackets for 19“

installation, 345 x 44 x 253 mm (W x H x D)
Number of fans| 1 quiet fan

Interfaces

G.FAST / VDSL 1 / VDSL 2| G.FAST acc. to ITU G.9700 and G.9701, profiles 106a, 212a VDSL2 acc. to ITU G.993.2, profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a, 35b VDSL supervectoring acc. to ITU G.993.2 (Annex Q) VDSL2 vectoring: acc. to ITU G.993.5 (G.Vector) Compatible with VDSL2 from Deutsche Telekom Compatible with the U-R2 connection of Deutsche Telekom (1TR112) ADSL2+ over ISDN acc. to ITU G.992.5 Annex B/J with DPBO, ITU G.992.3 and ITU G.992.1 ADSL2+ over POTS acc. to ITU G.992.5 Annex A/M with DPBO, ITU G.992.3 and ITU G.992.1 Supports only one virtual connection in ATM (VPI-VCI pair) at a time Automatic detection of Deutsche Telekom VDSL connections with VLAN ID 7
---|---
WAN 1 / WAN 2| WAN 1 SFP: Compatible with optional LANCOM SFP modules. Set as a WAN port ex-factory, can be configured as a LAN port. WAN 1 / WAN 2 TP: 10 / 100 / 1000 Base-TX, autosensing full duplex (WAN 1) / autosensing (WAN 2), auto node hub
ETH1 – ETH 4| 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode. Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically disabled in the LCOS configuration.
Analog 1 – Analog 4| Use the cables of your analog devices to connect them with the analog interfaces. If necessary, use the enclosed adapters.
ISDN 1 / ISDN 2| ISDN 1: Internal (NT) ISDN bus. Connect the ISDN interface to an ISDN cable and the ISDN device. ISDN 2: Internal (NT) ISDN bus. Connect the ISDN interface to an ISDN cable and the ISDN device.
Config (Com) / V.24| Serial configuration interface / COM-port: 9,600 – 115,200 baud USB USB 2.0 hi-speed host port for connecting USB printers (USB print server), serial devices (COM-port server) or USB drives (FAT file system)

WAN protocols

G.Fast, VDSL, ADSL, Ethernet| PPPoE, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without DHCP), RIP-1, RIP-2, VLAN, GRE, EoGRE, L2TPv2 (LAC or LNS), IPv6 over PPP (IPv6 and IPv4/IPv6 dual stack session), IP(v6)oE (autoconfiguration, DHCPv6 or static)
---|---
ISDN| DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD

Package content

Cables| 2 DSL cables for IP-based connection, 4.25 m, or 2 DSL cables, 3 m (dark blue connectors), depending on the version; 1 Ethernet cable, 3 m (kiwi colored connectors); 1 IEC power cord 230 V (not for WW devices)
---|---
Adapters| 4 TAE adapters (RJ11 – TAE)
Mounting brackets| Two 19” brackets for rack mounting

*) The additional power LED statuses are displayed in 5-seconds rotation if the device is configured to be managed by the LANCOM Management Cloud

This product contains separate open-source software components which are subject to their own licenses, in particular the General Public License (GPL). The license information for the device firmware (LCOS) is available on the device‘s WEBconfig interface under “Extras > License information“.
If the respective license demands, the source files for the corresponding software components will be made available on a download server upon request.

Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance with Directives 2014/30/EU, 2014/53/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals