AES GLOBAL E-loop Commercial Radar Kit Instructions
- June 9, 2024
- AES GLOBAL
Table of Contents
GLOBAL E-loop Commercial Radar Kit
Instructions
E-loop Commercial Radar Kit
Uncalibrate e-LOOP
1. Place magnet into the SET button recess until the red LED flashes 4
times, e-LOOP is now uncalibrated.
Changing mode
The e-LOOP is set to pulse mode as standard setting. This can be changed to
presence mode via the menu in the e-TRANS-200 LCD transceiver – refer to the
manual.
NOTE: This menu cannot be accessed via the eTRANS-50 Transceiver.
Parameters that can be altered:
-
Pulse / Presence mode.
NOTE: do not use presence mode as a safety function. -
Wake-up time intervals for presence mode.
-
Sensitivity detection level for Pulse mode.
-
Sensitivity detection for presence mode by each axis: Above / Approach / Side.
-
Radar detection distance.
DISCLAIMER: UNITS WITH THE PRESENCEFEATURE IS NOT TO BE USED AS A SOLE SAFETY DEVICE & SHOULD BE USED IN CONJUNCTION WITH STANDARD GATE SAFETY PRACTICES.
Specifications
Frequency: 433.39 MHz.
Security: 128-bit AES encryption.
Range: up to 50 yards.
Battery life: up to 10 years.
Battery type: Lithium ion 3.6V 2600 mA x 4.
e-LOOP Fitting Instructions
Step 1 – Coding e-LOOP
Coding e-LOOP without Magnet
- Power up the e-Trans 50 and hold the e-Loop within 10cm of the transceiver’s antenna.
- Now press and release the CODE button on the e-Trans 50. The yellow and red LEDs will flash on the e-Loop, and the blue LED on the e-Trans 50 will flash 3 times. The systems are now paired.
(For coding e-Trans 200 LCD transceiver refer to e-Trans 200 manual.)
Coding e-LOOP with Magnet (Commercial systems only)
-
Power up the e-Trans 50, then press and release the CODE button.
The blue LED on the e-Trans 50 will light up. -
Now place the magnet on the CODE recess on the e-Loop – the yellow LED will flash 3 times, and the blue LED on the e-Trans 50 will flash 3 times. The systems are now paired and you can remove the magnet.
Step 2 – Fitting e-LOOP
1. Place e-LOOP device in the desired location and secure it into the
ground using 2 Dyna bolts. Ensure the e-LOOP device is secured and can’t be
moved when touched.
NOTE: Never fit near high voltage cables, this can affect the e-LOOP’s
detection capability.
Step 3 – Calibrate e-LOOP
- Move any metal objects away from the e-LOOP.
- Place magnet into the SET button recess on the e-LOOP until red LED flashes twice, then remove the magnet.
- The e-LOOP will take about 5 seconds to calibrate and once complete, the red LED will flash 3 times.
NOTE: After calibration, you may get an error indication.
ERROR 1: Low radio range – Yellow LED flashes 3 times.
ERROR 2: No radio connection – Yellow and Red LED flashes 3 times.
The system is now ready.
E. sales@aesglobalus.com
T: +1 – 321 – 900 – 4599
www.aesglobalus.com