Anolis Ambiane HP111 Pendant Remote User Manual
- June 3, 2024
- ANOLiS
Table of Contents
Anolis Ambiane HP111 Pendant Remote
Attention
- The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
- The unit was designed for indoor use only.
- Do not install the unit near highly inflammable liquids or materials.
- Do not allow anything to rest on the unit.
- Do not install the unit near an open flame.
- Do not install the unit in dirty, dusty or badly ventilated location.
- Avoid looking directly into the light beam at close range!
- A ceiling (structure) intended for installation of the unit(s) must safely hold at least 5 times the weight of the unit(s) fastened on it.
- Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity.
- The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m.
- The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g. transmitters in surrounding area) before installing the equipment.
- Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.
Fixture exterior view
Installation
The Ambiane HP111 Pendant Remote must be installed by a qualified electrician
in accordance with all national and local electrical and construction codes
and regulations. Always switch off power supply of the control unit before
connecting or disconnecting the control unit or the light unit.
The lower ceiling (or another structure) intended for installation of the
Ambiane(s) HP111 Pendant Remote must safely hold at least 5 times weight of
the Ambiane(s) HP111 Pendant Remote placed on it.
- Fasten the control unit (1) on the ceiling by means of two holes in the housing of the control unit.
- Fasten the ceiling plate M6i (3) to the lower ceiling.
- Screw the spherical cap (4) with the hanging wire (6) to the ceiling plate M6i (3).
- Drill the hole (diameter of 8mm) in the lower ceiling for the LED unit supply cable (7). If you wish to have the LED unit supply cable (7) parallel with the hanging wire (6), the distance between the hanging wire and the LED unit supply cable should be 34 mm.
- Secure the LED unit supply cable (7) above ceiling against loosing from the control unit (1).
- Install the terminal block (9) on the supply cable connect it to the PCB RB 3729 of the control unit (1).
- Install the terminal block (10) on the DMX cable and connect it to the PCB RB 3729 of the control unit (1).
- Install the terminal block (11) on the LED unit cable (7) and connect it to the to the PCB RB 3729 of the control unit (1).
- Install another terminal blocks on cables according to requirements of current installation.
Example of connection: Note: The trimmer (13) allows you to set a light
intensity (for secondary power only). This trimmer is accessible by aperture
(18) in the cover of the control unit (1).
LED unit connection
Connector | + | A | B | – |
---|---|---|---|---|
Function | LEDs + | Data A | Data B | LEDs – |
Colour of wire | Red | White | Blue | Black |
Primary power connection
Connector | Vcc | 0V |
---|---|---|
Function | Power + | Power – |
Secondary power connection
Connector | Vcc | 0V |
---|---|---|
Function | Power + | Power – |
Recommended diameters of conductors with respect to distance between the Control unit and the power supply (e.g. Ambiane Power HP):
Distance/cable length | 25 m | 50 m | 75 m | 100 m |
---|---|---|---|---|
Diameters of conductors | 0.5 mm2 | 1 mm2 | 1.5 mm2 | 2 mm2 |
DMX connection
Connector | D+ | D- | 0V |
---|---|---|---|
Function | Data + | Data- | Data ground(shielding) |
0-10V connection
Connector | D+ | 0V |
---|---|---|
Function | +10V | 0V |
- DMX connectors are used for 0-10V control
- The primary power input serves for a standard power (e.g. Ambiane Power HP).
- The secondary power input serves for a backup power (in case that primary power failed).
- If both power inputs are under voltage, the primary power has a priority and the secondary power is disabled. In case of primary power loss, the secondary power is enabled.
- If the fixture is supplied via the secondary power, the light output of the fixture is a white colour (3200K) and its light intensity can be set by the trimmer (13) accessible by aperture (18) in the cover of the control unit (1).
Set the DIP switch (12) according to your operation mode. This DIP switch is accessible by aperture (18) in the cover of the control unit (1).
The fixture can be controlled by one of the following methods:
- DMX 512
- DALI
- 0-10V (PW or TD version only)
The fixture is equipped with two DMX and DALI connection blocks (on the PCB RB 3729) for easy connection to a DMX or DALI chain (In/Out method).
Set desired position of the LED unit by means of the hanging wire (6). If you need to pull the hanging wire (6) out of the wire lock, you have to press and hold the part (16) of the wire lock. If you need to align the LED unit, use the three locks on the hanging wires (15). To pull the hanging wire (15) out of the wire lock, you have to press and hold the part (17) of the wire lock .
Ring Louver installation
Snap the Ring Louver (18) to the LED unit (8).
DMX and DALI address setting and control
The DIP switch on the control PCB (RB3729) allows you to set DMX address and run a test light.
- DIP 10 – if it is switched to ON=test light (the fixture lights at 3200K (for RGBW and TW version))
- DIP 11 – has to be switched to OFF position to receive DMX 512 and DALI, position ON=0-10V control
Note: If DIP 11=OFF (fixture is controlled by DMX and DALI), the last
coming command switches the fixture to the corresponding operation mode (DMX
operation by a DMX command, DALI operation by a DALI command). E.g. the
fixture stays in a DALI operation and last coming command is a DMX command
which switches the fixture to DMX operation. Next command is a DALI command
and switches the fixture to the DALI operation etc.
If you need the permanent DALI operation, you have to send a DALI command 8 to
the fixture.
DMX control
The DMX start address, is the first channel used to receive instructions from the DMX controller. The address may be any channel from 1 to 512. DMX address can be set either by DIP switch or by RDM. DMX address set by RDM overwrites address set by DIP switch and vice versa. The green LED on PCB signals way of DMX address setting:
- LED lights-DMX address is set by means of the DIP switch.
- LED does not light-DMX address is set by means of RDM.
The DIP 11 has to be set to OFF position. Example of DMX addresses:
DALI control
Addressing of the fixture has to be made by means of an external DALI
controller.
If you need to start the permanent DALI control of the fixture (fixture will
not respond to DMX commands), the external DALI controller has to send
activating command (8=ON).
If you need to stop the permanent DALI control of the fixture, the external
DALI controller has to send deactivating command (0=OFF).
0-10V control
DIP 11 has to be set in ON position. 0-10V operation has priority to DALI and
DMX commands. The option is applicable for the PW and TD version of the
Ambiane HP111 Pendant Remote only.
RDM
This fixture supports RDM operation. RDM (Remote Device Management) is a bi- directional communication protocol for use in DM X512 control systems, it is the new open standard for DMX512 device configuration and status monitoring. RDM allows you to set a DMX address, select DMX mode, readout software version of the fixture etc. It is also used for fixture software update by means of the Robe Uploader.
RDM model ID for the Ambiane HP111 Pendant Remote is: 0x0114.
Parameter ID | Discovery command | SET command | GET command |
---|---|---|---|
DISC_UNIQUE_BRANCH | * | ||
DISC_MUTE | * | ||
DISC_UN_MUTE | * | ||
DEVICE_INFO | * | ||
SUPPORTED_PARAMETERS | * | ||
SOFTWARE_VERSION_LABEL | * | ||
DMX_START_ADDRESS | * | * | |
IDENTIFY_DEVICE | * | * | |
DEVICE_MODEL_DESCRIPTION | * | ||
MANUFACTURER_LABEL | * | ||
DEVICE_LABEL | * | * | |
DMX_PERSONALITY | ***** | ***** | |
DMX_PERSONALITY_DESCRIPTION | ***** | ||
RESET_DEVICE | * | ||
SENSOR_VALUE | * | * | |
SENSOR_DEFINITION | * | ||
SLOT_INFO | * | ||
SLOT_DESCRIPTION | * | ||
DEFAULT_SLOT_VALUE | * | ||
PARAMETER_DESCRIPTION | * |
DMX protocols
Variant RGBW, version 1.1
Mode 1
Channel
| Mode 2
Channel
| Mode 3
Channel
| Mode 4
Channel
| Mode 5
Channel
| DMX
value
| Function| Type of control
---|---|---|---|---|---|---|---
1| 1| 1| –| 1|
0-255
| Red
Red LEDs saturation control (0–>100%)
|
proportional
–| –| 2| –| –|
0-255
| Red Fine
Red LEDs saturation control (0–>100%)
|
proportional
2| 2| 3| –| 2|
0-255
| Green
Green LEDs saturation control (0-100%)
|
proportional
–| –| 4| –| –|
0-255
| Green Fine
Green LEDs saturation control (0–>100%)
|
proportional
3| 3| 5| –| 3|
0-255
| Blue
Blue LEDs saturation control (0 –>100%)
|
proportional
–| –| 6| –| –|
0-255
| Blue Fine
Blue LEDs saturation control (0–>100%)
|
proportional
4| –| 7| –| 4|
0-255
| White
White LEDs saturation control (0–>100%)
|
proportional
–| –| 8| –| –|
0-255
| White Fine
White LEDs saturation control (0–>100%)
|
proportional
–| –| 9| 1| | | Green correction|
| | | | 0| Uncorrected white| step
| | | | 1-127
128
129-
255
| Minus green –> uncorrected white Uncorrected white (128=default) Uncorrected white –> Plus green| proportional
step
proportional
–| –| 10| 2| | | Colour temperature correction (CTC)|
| | | | 0| No function (0=default)| step
| | | | 1-10| Tungsten dimming 2700 K| step
| | | | 11-20| Tungsten dimming 3200 K| step
| | | | 21-255| Colour temperature changing 2700 K–> 6500 K| proportional
–| –| 11| 3| 5|
0-255
| Dimmer
Light intensity coarse (0–>100%)
|
proportional
–| –| 12| –| 6|
0-255
| Dimmer Fine
Light intensity fine (0–>100%).
|
proportional
DMX mode has to be set by RDM.
Variant TW, version 1.1
Mode 1
Channel
| Mode 2
Channel
| DMX
value
| Function| Type of
control
---|---|---|---|---
1| –|
0-255
| White colour selection
White from 2700K–>4000K
|
proportional
–
| 1|
0-255
| Warm White
Warm white LEDs saturation control (0–>100%)
|
proportional
–
| 2|
0-255
| Cool White
Cool white LEDs saturation control (0–>100%)
|
proportional
2| 3|
0-255
| Dimmer
Light intensity (0–>100%)
|
proportional
Variant TD, PW version 1.1
Mode 1
Channel
| Mode 2
Channel
| DMX
value
| Function| Type of
control
---|---|---|---|---
1| 1|
0-255
| Dimmer
Light intensity coarse (0–>100%)
|
proportional
–| 2|
0-255
| Dimmer Fine
Light intensity (0–>100%)
|
proportional
Technical specifications
- Nominal input voltage: 48V DC
- Input voltage range: 4 4-50V DC
- Max. power consumption: 75W
- Light source: High Power LED module
- Beam angle: 20°, 40°,60°, 80°
- Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F °F)
- Colour Variants: RGBW (W – 2700K or 4000K), PureWhite, Tunable White, Tungsten Dim
- Colour Temperature of White: PW 2700 K or 4000K, TW 2700 – 4000K, TD 3200K
- CRI: 90+
- Control: DMX, DALI 2 , RDM, 0-10V
- Settings/Addressing: DIP Switch, RDM
- DMX channels (RGBW variant): 4 (Mode 1), 3 (Mode 2), 12 (Mode 3), 3 (Mode 4), 6 (Mode 5)
- DMX channels (TW variant): 2 (Mode 1), 3 (Mode 2)
- DMX channels (TD, PW variant): 2 (Mode 1), 2 (Mode 2)
- Power supply (CE): Ambiane Power HP (48V/100W), Ambiane Power Rack
- Power supply (US): Ambiane Power HP (48V/100W), Ambiane Power Rack US
- Operating ambient temp. range: -20 °C / +40 °C (-4 °F / +104 °F)
- Operating Temperature (LED unit): +75 °C @ Ambient +40 °C (167 °F @ Ambient 104 °F)
- Total heat dissipation: 191 BTU/h (calculated)
- Cooling: c onvection
- Housing: High Pressure Die-Cast Aluminium Body
- Weight (without control unit) :
- Ambiane HP111 Pendant Remote 20° 2.6 kg/ 5.7 lbs
- Ambiane HP111 Pendant Remote 40° 3.1 kg/ 6.8 lbs
- Ambiane HP111 Pendant Remote 60° 2.5 kg/ 5.5 lbs
- Ambiane HP111 Pendant Remote 80° 2.5 kg/ 5.5 lbs
- Mounting Method: Pendant with 1 adjustable hanging wire
- IC rating: Non-IC rated
- Power connection Connectors
- DMX connection: Connectors
- DALI connection: Connectors
- LED unit connection: Connector
- Protection factor (CE): IP20
- Protection factor (US): Dry location only
Dimensions
mm [inch]
- Ambiane HP 20° H = 302 mm [11 7/8 in.]
- Ambiane HP 40° H = 298 mm [11 3/4 in.]
- Ambiane HP 60° H = 285 mm [11 1/4 in.]
- Ambiane HP 80° H = 268 mm [10 9/16 in
Control unit
Included items
- 1 x Ambiane HP111 Pendant Remote
- 1 x Control unit
- 1 x Set of cable connectors
- 1 x User manual
Optional accessories
- Ambiane Power HP (MeanWell ELG-100-48-3Y) (P/N 10064073)
- Ambiane Power Rack (P/N 10063951), black colour
- Ambiane Power Rack US (P/N 10063873), black colour
- Ring Louver for Ambiane HP111 Pendant Remote 20°
Cleaning and maintenance
Keep the fixture clean, especially light source and the ribbed ribbed heat
sink.
Maintenance and service operations are only to be carried out by a qualified
person.
Should you need any spare parts, please use ROBE OEM parts.
Software update
The fixture has to be connected to power during software update.
Software update by means of the Robe Uploader
The ROBE Uploader is a software for automatized software update of Robe and
Anolis fixtures. It can take advantage of RDM support.
The fixtures have to be connected in a daisy-chain (max. 32 fixtures) and via
the Robe Universal Interface/Robe Universal Interface WTX and a USB cable
connected to the control PC with the Robe Uploader running.
The fixtures have to be connected to power. The control PC should be connected
to the Internet.
The Robe Uploader software and user manual is available at
https://www.robe.cz/robe-uploader/
If you do the software update by means of the Robe Uploader, switching
fixtures to the update mode (and from the update mode) is made automatically.
Note: The Robe Uploader software cannot be used if fixtures are connected
by means of DALI connection.
Disposing of the product
To preserve the environment please dispose or recycle this product at the end
of its life according to the local regulations and codes.
June 16, 2022
Copyright © 2022 Robe Lighting – All rights reserved
All Specifications subject to change without notice
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701
Valasske Mezirici
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>