MEAN WELL TS-1000 Series 1000W True Sine Wave DC-AC Power Inverter Instructions

June 9, 2024
MEAN WELL

MEAN WELL TS-1000 Series 1000W True Sine Wave DC-AC Power Inverter
MEAN WELL TS-1000 Series 1000W True Sine Wave DC-AC Power
Inverter

Features

User’s Manual
User’s Manual

  • True sine wave output (THD<3%)
  • High surge power up to 2000W
  • High efficiency up to 92%
  • Power ON-OFF switch
  • Standby saving mode can be selected
  • Front panel indicator for operation status
  • Built-in fan ON-OFF control function
  • Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp./ Output short / Input reverse polarity / Overload
  • Application : Home appliance, power tools, office and portable equipment, vehicle and yacht …etc.
  • 3 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL NO.| TS-1000-112| TS-1000-124| TS-1000-148| TS-1000-212| TS-1000-224| TS-1000-248
---|---|---|---|---|---|---
= A, F| = B, C, D





OUTPUT

| RATED POWER (Typ.)| 1000W
MAXIMUM OUTPUT POWER (Typ.)| 1150W for 180 sec. / 1500W for 10 sec. / surge power 2000W for 30 cycles
AC VOLTAGE| Factory setting set at 110VAC| Factory setting set at 230VAC
100 / 110 / 115 / 120VAC selectable by setting button S.W| 200 / 220 / 230 / 240VAC selectable by setting button S.W
FREQUENCY Note.8| 60±0.1Hz   50/60Hz selectable by setting button S.W| 50±0.1Hz   50/60Hz selectable by setting button S.W
WAVEFORM Note.6| True sine wave (THD<3%)
AC REGULATION (Typ.)| ±3.0%
SAVING MODE (Typ.)| Default disabled. Load≦5W will be changed to standby mode
FRONT PANEL INDICATOR| Battery voltage level, output load level, saving mode, fault and operation status




INPUT

| BAT. VOLTAGE| 12V| 24V| 48V| 12V| 24V| 48V
VOLTAGE RANGE (Typ.) Note.4,6| 10.5 ~ 15VDC| 21 ~ 30VDC| 42 ~ 60VDC| 10.5 ~ 15VDC| 21 ~ 30VDC| 42 ~ 60VDC
DC CURRENT (Typ.)| 100A| 50A| 25A| 100A| 50A| 25A
NO LOAD DISSIPATION (Typ.)| ≦6W @ standby saving mode
OFF MODE CURRENT DRAW| ≦1mA
EFFICIENCY (Typ.) Note.1| 88%| 89%| 90%| 90%| 91%| 92%
BATTERY TYPES| Open & sealed lead acid


BATTERY INPUT PROTECTION

| FUSE| 40A4| 40A2| 20A2| 40A4| 40A2| 20A2
BAT. LOW ALARM| 11.3±4%| 22.5±4%| 45±4%| 11.3±4%| 22.5±4%| 45±4%
BAT. LOW SHUTDOWN| 10.5±4%| 21±4%| 42±4%| 10.5±4%| 21±4%| 42±4%
REVERSE POLARITY| By internal fuse open



OUTPUT PROTECTION

| OVER TEMPERATURE| 90℃± 5℃| 70℃± 5℃
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power diode
OUTPUT SHORT| Protection type : Shut down o/p voltage, re-power on to recover
OVER LOAD (Typ.)| 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
GFCI PROCTECTION| Optional (Only type F)| None


ENVIRONMENT

| WORKING TEMP. Note.3| 0 ~ +40℃ @ 100% load ; +60℃ @ 50% load
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non- condensing
VIBRATION| 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes


SAFETY & **EMC**

| SAFETY STANDARDS| UL458 (only for “GFCI” receptacle-Type F ), EAC TP TC 004| EAC TP TC 004| IEC62368-1 CB, EAC TP TC 004 approved; Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE| Bat I/P – AC O/P:3.0KVAC  AC O/P – FG:1.5KVAC
ISOLATION RESISTANCE| Bat I/P – AC O/P, Bat I/P – FG, AC O/P – FG: 100M ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to FCC class A, EAC TP TC 020| Compliance to BS EN/EN55032 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark, EAC TP TC 020
EMC IMMUNITY| Compliance to EAC TP TC 020| Compliance to BS EN/EN61000-4-2,3,8, BS EN/EN55035, EAC TP TC 020


OTHERS

| MTBF| 528.8K hrs min.      Telcordia SR-332 (Bellcore) ; 80.7K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION| 34518470mm (LWH)
PACKING| 4.3Kg; 2pcs/9.6Kg/1.16CUFT
COOLING| Loading controlled cooling fan for GFCI receptacle-type F ; Thermostatically controlled cooling fan for others.
NOTE|

  1. Efficiency is tested by 750W, linear load at 13V, 26V, 52V input voltage.
  2. All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
  3. Output derating capacity referenced by curve 1.
  4. Input derating capacity referenced by curve 2.
  5. The tolerance of each voltage value by models is:112/212→±0.5V;124/224→±1V;148/248→±2V
  6. THD is tested by 1000W, linear load at 13,26,52V input voltage.
  7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  8. Type F for 60Hz only.

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

SPECIFICATION

AC Output Socket (optional)

MODEL NO.| TS-1000-112| TS-1000-124| TS-1000-148| TS-1000-212| TS-1000-224| TS-1000-248
---|---|---|---|---|---|---
Socket type|

|

AC Output Socket

TYPE-A| TYPE-F| TYPE-B| TYPE-C| TYPE-D
Standard| Optional| Standard| Optional| Optional
Country| USA| GFCI (60Hz)| EUROPE| AUSTRALIA| U.K
Certificate|

| | **

|

**|

**

**

Mechanical Specification

Mechanical Specification
Mechanical Specification

Derating Curve

Derating Curve
Derating Curve
Derating Curve