MEAN WELL TS-1000 Series 1000W True Sine Wave DC-AC Power Inverter Instructions
- June 9, 2024
- MEAN WELL
Table of Contents
MEAN WELL TS-1000 Series 1000W True Sine Wave DC-AC Power Inverter
Features
- True sine wave output (THD<3%)
- High surge power up to 2000W
- High efficiency up to 92%
- Power ON-OFF switch
- Standby saving mode can be selected
- Front panel indicator for operation status
- Built-in fan ON-OFF control function
- Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp./ Output short / Input reverse polarity / Overload
- Application : Home appliance, power tools, office and portable equipment, vehicle and yacht …etc.
- 3 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL NO.| TS-1000-112| TS-1000-124| TS-1000-148|
TS-1000-212| TS-1000-224| TS-1000-248
---|---|---|---|---|---|---
= A, F| = B, C, D
OUTPUT
| RATED POWER (Typ.)| 1000W
MAXIMUM OUTPUT POWER (Typ.)| 1150W for 180 sec. / 1500W for 10 sec. /
surge power 2000W for 30 cycles
AC VOLTAGE| Factory setting set at 110VAC| Factory setting set at 230VAC
100 / 110 / 115 / 120VAC selectable by setting button S.W| 200 / 220 / 230 /
240VAC selectable by setting button S.W
FREQUENCY Note.8| 60±0.1Hz 50/60Hz selectable by setting button
S.W| 50±0.1Hz 50/60Hz selectable by setting button S.W
WAVEFORM Note.6| True sine wave (THD<3%)
AC REGULATION (Typ.)| ±3.0%
SAVING MODE (Typ.)| Default disabled. Load≦5W will be changed to standby
mode
FRONT PANEL INDICATOR| Battery voltage level, output load level, saving
mode, fault and operation status
INPUT
| BAT. VOLTAGE| 12V| 24V| 48V| 12V| 24V| 48V
VOLTAGE RANGE (Typ.) Note.4,6| 10.5 ~ 15VDC| 21 ~ 30VDC| 42
~ 60VDC| 10.5 ~ 15VDC| 21 ~ 30VDC| 42 ~ 60VDC
DC CURRENT (Typ.)| 100A| 50A| 25A| 100A| 50A| 25A
NO LOAD DISSIPATION (Typ.)| ≦6W @ standby saving mode
OFF MODE CURRENT DRAW| ≦1mA
EFFICIENCY (Typ.) Note.1| 88%| 89%| 90%| 90%| 91%| 92%
BATTERY TYPES| Open & sealed lead acid
BATTERY INPUT PROTECTION
| FUSE| 40A4| 40A2| 20A2| 40A4| 40A2| 20A2
BAT. LOW ALARM| 11.3±4%| 22.5±4%| 45±4%| 11.3±4%| 22.5±4%| 45±4%
BAT. LOW SHUTDOWN| 10.5±4%| 21±4%| 42±4%| 10.5±4%| 21±4%| 42±4%
REVERSE POLARITY| By internal fuse open
OUTPUT PROTECTION
| OVER TEMPERATURE| 90℃± 5℃| 70℃± 5℃
Protection type : Shut down o/p voltage, re-power on to recover; by internal
RTH3 detect on heatsink of power diode
OUTPUT SHORT| Protection type : Shut down o/p voltage, re-power on to
recover
OVER LOAD (Typ.)| 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10
sec.
Protection type : Shut down o/p voltage, re-power on to recover
GFCI PROCTECTION| Optional (Only type F)| None
ENVIRONMENT
| WORKING TEMP. Note.3| 0 ~ +40℃ @ 100% load ; +60℃ @ 50% load
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-
condensing
VIBRATION| 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC**
| SAFETY STANDARDS| UL458 (only for “GFCI” receptacle-Type F ), EAC TP
TC 004| EAC TP TC 004| IEC62368-1 CB, EAC TP TC 004 approved; Design refer to
BS EN/EN62368-1
WITHSTAND VOLTAGE| Bat I/P – AC O/P:3.0KVAC AC O/P – FG:1.5KVAC
ISOLATION RESISTANCE| Bat I/P – AC O/P, Bat I/P – FG, AC O/P – FG: 100M
ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to FCC class A, EAC TP TC 020| Compliance to BS
EN/EN55032 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark, EAC TP TC 020
EMC IMMUNITY| Compliance to EAC TP TC 020| Compliance to BS
EN/EN61000-4-2,3,8, BS EN/EN55035, EAC TP TC 020
OTHERS
| MTBF| 528.8K hrs min. Telcordia SR-332 (Bellcore) ; 80.7K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 34518470mm (LWH)
PACKING| 4.3Kg; 2pcs/9.6Kg/1.16CUFT
COOLING| Loading controlled cooling fan for GFCI receptacle-type F ;
Thermostatically controlled cooling fan for others.
NOTE|
- Efficiency is tested by 750W, linear load at 13V, 26V, 52V input voltage.
- All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
- Output derating capacity referenced by curve 1.
- Input derating capacity referenced by curve 2.
- The tolerance of each voltage value by models is:112/212→±0.5V;124/224→±1V;148/248→±2V
- THD is tested by 1000W, linear load at 13,26,52V input voltage.
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- Type F for 60Hz only.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
AC Output Socket (optional)
MODEL NO.| TS-1000-112| TS-1000-124| TS-1000-148|
TS-1000-212| TS-1000-224| TS-1000-248
---|---|---|---|---|---|---
Socket type|
|
TYPE-A| TYPE-F| TYPE-B| TYPE-C| TYPE-D
Standard| Optional| Standard| Optional| Optional
Country| USA| GFCI (60Hz)| EUROPE| AUSTRALIA| U.K
Certificate|
| | **
|
**|
**
**
Mechanical Specification
Derating Curve
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>