European Home JVF-40H Outdoor Gas Fireplace Instruction Manual

June 13, 2024
European Home

European Home Logo Installation, Operation, and Owner’s Manual
JVF-40H-S JVF-40H-ST Gas Fireplaces
J SERIES
Outdoor · Gas · Fireplace

JVF-40H Outdoor Gas Fireplace

Single-Sided Product Information Page

https://europeanhome.com/product/jvf40hm2-ss/

See-Through Product Information Page

European Home JVF40H Outdoor Gas Fireplace - QR Code 1 https://europeanhome.com/product/jvf40hm2-st/

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any otherappliance.
WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.
    –An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. Solid fuels shall not be burned in this appliance.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING: FOR OUTDOOR USE ONLY

DANGER CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor.

Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent, car or home.

This manual is available in Canadian French upon request.

IMPORTANT SAFETY INFORMATION

Read these instructions carefully before installing or trying to operate this gas appliance.
Thank you for purchasing a JVF Series Outdoor Gas Fireplace by European Home. This fireplace has been designed to provide you with safe, trouble-free operation. Please read this manual thoroughly before beginning the installation of your fireplace. It has information which is important for safe installation and operation. Please inspect your shipment for completeness and any damage. Contact your retailer if any damage is found.
Do not install your appliance with any damaged or substituted parts. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. young children should be carefully supervised when they are in the area of the appliance. Clothing or other flammable materials should not be hung from the appliance or placed on or near the appliance. Any guard or other protective device removed for servicing the appliance shall be replaced prior to operating the appliance. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary.
It is imperative that the control compartment, burners, and circulating air passageways of the appliance are kept clean.
SOLID FUELS SHALL NOT BE BURNED IN THIS APPLIANCE
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.

IMPORTANT SAFETY INFORMATION ABOUT PROPANE (LP) GAS

This gas fireplace is equipped at the factory for use with natural gas. If conversion to propane (lP) is desired, the optional factory-supplied conversion kit must be used.
When using propane (lP), the gas supply cylinder to be used must be:

  1. constructed and marked in accordance with the u.S. Department of Transportation (D.O.T.) Specifications for lP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Commission, CAN/CSA-B339, as applicable,
  2. provided with a listed overfilling prevention device, and
  3. provided with a cylinder connection device compatible with the connection for the appliance.
  4. If lP is hard plumbed to the fireplace, the propane storage tank must have a pressure regulator set for 11” w.c. (2.74 kPa).

Note
If a propane hose is used to connect a propane cylinder to the fireplace, the following is required:
Inspect the hose before each use of the fireplace.
The hose assembly must be replaced prior to the fireplace being put into operation if there is evidence of excessive abrasion or wear or if the hose is damaged. The replacement hose assembly must be a regulator hose with a QCC-1 connection and an outlet pressure set for 11” w.c. (2.74 kPa). locate the hose out of pathways where people may trip over it or in areas where the hose may be subject to accidental damage.

SPECIFICATIONS AND DIMENSIONS

SPECIFICATIONS

Model JVF-40H-S JVF-40H-ST
Gas Natural
Gas LP

(Propane)
Input Maximum| Btu/hr| 65,678| 64,211
Input Minimum| Btu/hr| 49,901| 48,308
Maximum Supply
Pressure| in. w.c.| 7.0| 11.0
kPa| 2.| 3.
Manifold Pressure
Maximum| in. w.c.| 6.| 10.
kPa| 1.| 3.
Manifold Pressure
Minimum| in. w.c.| 4.| 6.0
kPa| 0.87| 2.
Electrical Rating| V AC| 120

European Home JVF40H Outdoor Gas Fireplace -DIMENSIONS

European Home JVF40H Outdoor Gas Fireplace -DIMENSIONS
1

European Home JVF40H Outdoor Gas Fireplace -DIMENSIONS
2

CERTIFICATION
OMNI-Test laboratories, Inc. has certified that the J Series Outdoor Gas Fireplace meets the following standards:

  • ANSI Z21.97-2017 “Outdoor decorative gas appliances”
  • CSA 2.41-2017 “Outdoor decorative gas appliances””
  • CSA 2.17-2017, “Gas-Fired Appliances for use at High Altitudes”

J Series Outdoor Gas Fireplace
Model: JVF-40H-ST JVF-60-M2-01 JVF-60-M2-ST-01
Serial Number: Input BTU/hr. (NG/LP): 65,000
Orifice Size (NG): 2x#39 DMS Orifice Size (LP): 2x 0.064 Gas Control: Max. Supply Pressure (NG): 7 inches w.c. Manifold Pressure (NG): 5.5 inches w.c. Max. Supply Pressure (LP): 11 inches w.c. Manifold Pressure (LP): Copreci 10.25 inches w.c.
Electrical Rating: 120V AC, less than 2A JVF-40H-S
This appliance is equipped for: Natural Gas   Propane.
CLEARANCES

Top of fireplace to combustibles: 4.0″
Top of fireplace opening to combustibles: 6.0″
Back of fireplace to back combustible wall: 0.0″
Side of fireplace to side wall: 0.0″
Side of fireplace opening to combustible trim: 4.5″
Fireplace opening to side wall in front of fireplace: 5.5″
Top of fireplace opening to combustible mantel: 17.0″
Front of fireplace to back combustible wall: 18.0″
Maximum depth of mantel: 12.0″

For Outdoor Use Only.
For installation on (or over) Non-Combustible Floors Only

DANGER CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor.

Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent, car or home.

LIGHTING INSTRUCTIONS

  1. On the remote control, press the “ON” button.
  2. When the flames are at the high setting, press the “LOW” button to set the flames to low
  3. When the flames are at the low setting, press the “HIGH” button to set the flames to high

TO TURN OFF GAS

  1. On the remote control, press the “OFF” button.

WARNING   Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance, or additional information, consult a qualified installer, service agency, or the gas supplier.
WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. This product has been certified by OMNI-Test Laboratories to ANSI Z21.97-2017/CSA 2.412017 Outdoor Decorative Gas Appliances. This appliance must be installed in accordance with local codes, if any; if none, follow the ANSI Z223.1 standard. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Report # 0284GF009S
JM2LL01180913

EUROPEAN HOME
30 Log Bridge Road
Building 300 Suite 303
Middleton, MA 01949
tel: 781-324-8383
europeanhome.com

FIGURE 4: Sample Listing Label (affixed beneath the Light Panel)
A sample listing label image is shown above. A metal listing label is attached to every European Home fireplace and contains important certification information. The listing label must not be removed from the fireplace.
WHEN ENCLOSING YOUR FIREPLACE THE USE OF NON-COMBUSTIBLE BUILDING MATERIALS IS REQUIRED. PLEASE READ AND UNDERSTAND THE FOLLOWING.
COMBUSTIBLE MATERIALS
Materials that can catch fire and burn are considered combustible. Any material that is made of, or faced with;wood, wood pulp, paper, plastic or any other material that can catch fire and burn is considered combustible.
Even though these materials may have been ‘flame-proofed’, made ‘fire- resistant’ or are ‘fire-rated’ they are considered combustible. Standard and Type X drywall are both combustible.
NON-COMBUSTIBLE MATERIALS
A material is non-combustible when it cannot catch fire and burn. For example, materials made of stone, brick, concrete, tile, steel, plaster or glass are non-combustible.
Since this fireplace may be installed only outdoors, it is important to select materials that are suited for outdoor conditions.

CLEARANCES

CLEARANCES TO COMBUSTIBLES

European Home JVF40H Outdoor Gas Fireplace
-COMBUSTIBLES

A Top of fireplace to ceiling of enclosure 4”
B Back of fireplace to back combustible wall 0”
C Side of fireplace opening to combustible trim 4.5”
D Fireplace opening to side wall in front of fireplace 5.5”
E Side of fireplace to combustible side wall 0”
F Top of fireplace opening to combustibles 7”
G Top of fireplace opening to combustible mantel 17”
Maximum depth of mantel 12”

INSTALLATION

LOCATING THE FIREPLACE
When locating your J Series Outdoor Gas Fireplace, you must ensure that the proper clearances to combustible materials are maintained and your fireplace must be installed outdoors, NOT indoors. The fireplace may be installed unsheltered but wind may cause a flame outage and/or excessive sooting. If enclosed, or sheltered, the enclosure must be: a. an enclosure with walls on all sides but NO overhead cover; or

European Home JVF40H Outdoor Gas Fireplace -FIREPLACE

a partial enclosure that includes an overhead cover but NO MORE THAN TWO side walls; or

European Home JVF40H Outdoor Gas Fireplace -FIREPLACE
1b. a partial enclosure that includes an overhead cover and three side walls, as long as 30 percent or more of the horizontal periphery of the enclosure is permanently open.
– 25% total area completely open.
– 30% of remaining wall area is open and unrestricted.
– Screens only count for 40% of the total open area on windows.

European Home JVF40H Outdoor Gas Fireplace -FIREPLACE
2

ELECTRIC INSTALLATION

Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
This appliance must be electrically grounded in accordance with local codes, or, in the absence of local codes, with either the National Electrical Code ANSI/NFPA 70, for installations in the U.S. or the Canadian Electrical Code, CSA C22. 1 for installations in Canada.
Electrical work should only be performed by a qualified, licensed electrician. Electric power must be off when making connections or performing any service.
All wiring shall be in compliance with all local, city, and state codes. Verify proper operation after servicing.
The JVF-40H fireplace must be wired to a GFCI protected 120V AC circuit using a waterproof connector. The weatherproof control box is attached to a 65 inch long power cable on the left side of the fireplace.

European Home JVF40H Outdoor Gas Fireplace -ELECTRIC

European Home JVF40H Outdoor Gas Fireplace -LED LIGHT
SCHEMATICFIGURE 11: JVF-40H LED Lighting Schematic Diagram

GAS INSTALLATION

Note
The J Series Outdoor Gas Fireplace is shipped from the factory for use with natural gas.
A kit to convert the fireplace to propane (lP) is available. The conversion must be performed by a qualified service person. Contact your local gas supplier. Installation guide located in Appendix A
This product must be installed by a licensed plumber or gas fitter.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 /NFPA 54; National Fuel Gas Code; Natural Gas and Propane Installation Code, CSA B149.1; or Propane Storage and Handling Code, CSA B149.2, as applicable.
The fireplace and its individual shutoff valve must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
INSTALL THE NATURAL GAS SUPPLY
The natural gas supply piping must have a separate gas shutoff valve and a capped, 1/8” pipe tapping upstream of the valve for the purpose of reading pressure. A service shutoff valve must be placed within six feet of the fireplace gas control valve. Verify the gas pressure using the upstream 1/8” pipe tap.
The lower side of the control box is open 2” x 14”(50 mm x 355 mm) and allows for an easy gas supply connection to the gas valve. The gas valve provides a 1/2” male flare fitting. This is located on the left face of the single sided unit and either side on the see-through unit.
PROPANE (LP) CYLINDER ENCLOSURE
If you are planning to operate your J Series Outdoor Gas Fireplace using a portable propane cylinder, it must be placed in an enclosure that meets the following specifications: A) One side of the enclosure must be left open and a chain located 12 “ (30.5 cm)above the floor of the enclosure must span the opening to prevent the tank from tipping. One end of the chain should be attached with a hook for easy removal of the tank.
B) Two ventilation openings must be provided in the sidewalls of the enclosure (Figure 12), located within 5 “ (127 mm) of the top of the enclosure, equally sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed. The opening(s) must have a total free area of not less than 1 square inch per lb. (14.2 cm 2 /kg) of stored fuel capacity.
The floor of the enclosure must be located 2 “ (50 mm) above the ground and must be non-combustible. The minimum width and the depth of the enclosure must be 13 “x 13” (330mm x 330mm) Ventilation openings must be provided at floor level of the enclosure and must have a total free area of not less than 1/2 in 2 /lb. (7.1 cm 2 /kg) of stored fuel capacity. If ventilation openings at floor level are in a sidewall, there must be at least two openings. The bottom of the openings must be 1 “ (25.4 mm) or less from the floor level and the upper edge no more than 5 “ (127 mm) above the floor level. The openings must be equally sized, spaced at a minimum of 90 degrees (1.57 rad) and unobstructed. Every opening must have minimum dimensions so as to permit the entrance of a 1/8 “ (3.2 mm) diameter rod. Ventilation openings in sidewalls must not communicate directly with other enclosures of the fireplace. The propane cylinder enclosure MuST be isolated from the fireplace but can be part of the fireplace enclosure. See the example below.

European Home JVF40H Outdoor Gas Fireplace -LED LIGHT SCHEMATIC
1A regulator hose with a QCC-1 connection and an outlet pressure set for 11” w.c. (2.74 kpa) can be purchased at any retail outlet that offers gas  grill replacement parts. All parts of the hose mustremain inside the enclosure.

PROPANE CYLINDER ENCLOSURE REQUIREMENTS


A (Tank Size)| B (Upper Openings) Total in2 for 2 openings| C (Lower Openings) Total in2 for 2 openings
20 lb. tank (9.1 kg)| 20 in2 (130 cm2)| 10 in2 (65 cm2)
30 lb. tank (13.6 kg)| 30 in2 (195 cm2)| 15 in2 (100 cm2)

ENCLOSING THE FIREPLACE/FRAMING
All enclosures for the JVF-40H fireplace require an air inlet and an air outlet. These openings in the enclosure must allow for the free flow of air through the unit.
The air inlet opening must be located on the same side of the fireplace as the gas control and should be located near the bottom of the fireplace. This is the left side when facing the single sided model and either side on the see- through. The air outlet can be on any vertical surface above the unit. The air inlet opening and the air outlet opening must be covered with a grill that has a free area of at least 36 in2 (233 cm2). The grill opening should be small enough to prevent bugs, mice and other pests from accessing the enclosure. When choosing a grill, give consideration to its rain and/or weather resistance to ensure that as little weather gets inside the enclosure as possible. A small hood at the top of the grill is recommended for improved weather resistance. Make sure these hoods and grills do not effect the air intake.
IMPORTANT
From the air inlet to the controls side of the unit, there must be a chase baffle must be built to prevent air from passing around the back or top of the unit: Figure 13 below.

European Home JVF40H Outdoor Gas Fireplace - IMPORTANT

DO NOT PASS THIS PAGE uNlESS yOu HAVE uNDERSTANDING OF THE CHASE BAFFlE

ROUGH OPENING / FRAMING
A wall switch is included in a water-tight control box. Installation of the control box must be where children cannot reach for safety reasons.

European Home JVF40H Outdoor Gas Fireplace - IMPORTANT
1

Accumulated rain water will drain from a 7/8” (22.3mm) opening in the center rear of the fireplace bottom. This opening must not be blocked see Figures 19 & 20 for drain placement. The water which runs through this opening will accumulate in the base of your enclosure and must be allowed to drain away from the enclosure. An appropriate length of 11/2” – 2” PVC pipe installed at the base of the enclosure which runs down and out, is recommended. These openings must be checked for blockage periodically.

European Home JVF40H Outdoor Gas Fireplace - control
boxWhile combustible framing is permitted, metal framing is more appropriate for an outdoor enclosure. A typical installation is shown.

European Home JVF40H Outdoor Gas Fireplace - control box
1The fireplace is then placed in the framing.

European Home JVF40H Outdoor Gas Fireplace - control box
2The facing is applied to the framing.
The JVF-40H fireplace can come with one of two burners: a Campfire Burner or a linear Burner.
As you can see in the below images, the campfire kit only comes with a log set and the flames are higher and towards the center of the unit while the linear burner comes with fireglass or stones to cover the burner and the lights. Both fireplaces produce the same BTu and need the same pressures for Natural Gas and Propane.

European Home JVF40H Outdoor Gas Fireplace - CAMPFIRE
BURNER

TRIM and FINISH

INSTALLING THE WALL PANELS
The J Series Outdoor Gas Fireplace is shipped with two stainless steel wall panels. One to cover the fireplace controls and one decorative. These panels have a metal stud protruding from the top end of the panel. This stud should be inserted into the locator holes located on the ceiling of the fireplace at either end.
INSTALLING THE LIGHT COVERS
On the single sided models, install the clear glass in the back light area by laying it on the two angle brackets to cover the back light only, centered on the lED lights. On the see through models, install the clear glass in both light areas by laying it on the protruding studs located on the reflector panels to cover light. Make sure the clear glass is centered on the lED lights. Clear glass must be used. After the clear glass has been laid down, install the frosted glass which should lie parallel to the burners, covering the lights to hide them.
INSTALLING GLASS CAPTURE PANEL
After the installation of the frosted glass panels, install the glass capture panels between the end of the burner and wall panels. The lip of the glass capture panel should be installed under the lip of the burner. Secure using (2) supplied pan head screws
INSTALLING THE OPTIONAL WIND GUARD
A glass wind guard is optional for single sided models only. See-through models can not use the optional wind guards.

  1. Remove the screw securing the glass capture panel.European Home JVF40H Outdoor Gas Fireplace - TRIM
  2. Install the wind guard bracket using the screw for the glass capture panel.European Home JVF40H Outdoor Gas Fireplace - TRIM 1
  3. Slide the wind guard glass into the channel carefully, making sure to fully seat the glass into the bottom of the channels to ensure a secure and tight fit.European Home JVF40H Outdoor Gas Fireplace - TRIM 2

FIRE MEDIA

INSTALLING THE FIRE MEDIA – LINEAR BURNER
The J Series Outdoor Gas Fireplace is shipped with fire media which is to be installed on top of the burner.
Be certain that the fire media does not cover the pilot burner as well as no media is between the glass panels and burners to prevent glass breakage. Extra fire media can be ordered to cover the frosted glass. The Fire Media (Linear Burner) The fire media should be distributed evenly across the entire burner top. These fire media are available for the J Series Outdoor Gas Fireplace: (continued on next page)

European Home JVF40H Outdoor Gas Fireplace - FIRE
MEDIA

The fire media must be installed according to these instructions. This fireplace must use only the type and amount fire media specified by European Home. An excessive amount of fire media may adversely affect the performance of the fireplace.
WARNING: All previously applied loose material must be removed prior to reapplication.European Home JVF40H Outdoor Gas Fireplace - FIRE MEDIA
1

INSTALLING THE FIRE MEDIA – CAMPFIRE BURNER
The J Series Outdoor Gas Fireplace is shipped with fire media which is to be installed on top of the burner.
Be certain that the fire media does not cover the pilot burner. Do not support media with glass shield.
The Fire Media (Camp Fire Burner)
The fire media should be installed as described in the steps below.

European Home JVF40H Outdoor Gas Fireplace - CAMPFIRE BURNER
5

  1. Place the ashes and chips in the bottom of the burner and the glass holders, making sure not to cover or crowd the pilot assemblyEuropean Home JVF40H Outdoor Gas Fireplace - CAMPFIRE BURNERcover
  2. The following is a suggested log configuration for the JVF-40H. Install the logs as shown in the sequence of images below.European Home JVF40H Outdoor Gas Fireplace - nstall LogEuropean Home JVF40H Outdoor Gas Fireplace - nstall Log 1European Home JVF40H Outdoor Gas Fireplace - nstall Log 2European Home JVF40H Outdoor Gas Fireplace - nstall Log 3

OPERATING the FIREPLACE

FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
BEFORE lIGHTING, smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF yOu SMEll GAS

  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone.
  • Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.

PAIRING THE REMOTE TO THE RECEIVER (Refer to Figure 19 on following page)
Insert A23 12 volt battery (not supplied) into the remote control.
Press and release the top button of external control box. This is the “learn” button. A single long beep will be heard. learn window will remain open for 60 seconds.
Press “ON” button on remote. you will hear three short beeps confirming pairing.
OPERATING INSTRUCTIONS USING REMOTE CONTROL (Refer to Figure 19 on following page) SAFETy FEATuRE- When operating the fireplace with the wall switch, remote is inoperable and flame height will be same level of last setting.

  1. On the remote control, press and release the “ON” button. Sparking will occur 8 seconds after “ON: button is pressed
  2. Flames are automatically set to high. Press the “lOW” button on the remote control to set the flames to low.
  3. When the flames are at the low setting, press the “HI” button on the remote control to set the flames to high.

OPERATING INSTRUCTIONS USING THE WALL SWITCH

  1. Press the middle button of the wall switch
  2. Flames will be same level of last setting. To adjust flame height, press bottom button of wall switch.

TO TURN OFF FIREPLACE

  1. When using the remote control, press the “OFF” button.
  2. When using the wall switch, press the top button to the off position.

BURNER CONTROLS

European Home JVF40H Outdoor Gas Fireplace - FIREPLACE

USING THE LED LIGHT REMOTE
The lED remote control comes with a battery installed. When using the lED remote control, point the remote at the control side of the fireplace. The eye which receives the signal is located on the control side of the fireplace.

European Home JVF40H Outdoor Gas Fireplace - Remot
Control

TROUBLESHOOTING

Control Module Audible Alerts
One beep every one-second
Ignition Safety (Protection for Ignition system)
Description of Fault Action Pilot is not successfully ignited within the trial period. The control will operate the step motor in the gas valve to the OFF position. Cycle ON/ OFF switch to OFF position. How to Clear
Two beeps every one-second
Recycle Safety: (Protection for Unstable Pilot)
Description of Fault

  • Automatic Recycle – Pilot is proven and lost 3-times within 2-minutes without multiple ON/ OFF commands.

  • Automatic Recycle (VCS-ECOMODODS) – Pilot is established, then lost.

  • Manual Recycle – Ignition sequence is initiated 6-times within 2-minutes.
    The control will operate the step motor in the gas valve to the OFF position.
    Action How to Clear

  • After 5-minutes has elapsed (5-minute internal timer expires), the module must see the mode/switch in the OFF position after that time.

  • Once the module see’s the mode/ switch in the OFF position after the 5-minutes has elapsed, it will stop beeping.

  • Once the beeping has stopped, it will accept normal operation including another ON command from the user.

4 beeps every one-second (constant beeping)
Sensor Safety (Protection for Flame sensor)
Description of Fault Pilot flame sensor voltage is too high (>flame false threshold) when ignition sequence is initiated.
The control will operate the step motor in the gas valve to the OFF position.
Cycle the ON/OFF switch to the OFF position Action How to Clear
4 beeps every two-seconds
Thermal Safety (Overheat Protection)
Description of Fault Action
How to Clear
Internal temperature has exceeded 170 deg. F.
The module will operate the step motor in the gas valve to the OFF position.
Module’s internal temperature must cool to below 160 deg. F and cycle the ON/ OFF switch to the OFF position.

European Home JVF40H Outdoor Gas Fireplace -Burner
TroubleshootingEuropean Home
JVF40H Outdoor Gas Fireplace -Burner Troubleshooting 1European Home JVF40H Outdoor Gas Fireplace -Burner
Troubleshooting 2European Home
JVF40H Outdoor Gas Fireplace -Burner Troubleshooting .3European Home JVF40H Outdoor Gas Fireplace -Burner
Troubleshooting 4European Home
JVF40H Outdoor Gas Fireplace -Burner Troubleshooting 5

MAINTENANCE

A qualified service agency should conduct an annual inspection and maintenance of your J Series Outdoor Gas Fireplace to keep it running safely. The following procedures should be performed only by a qualified service person. The gas supply should be turned off whenever a maintenance procedure is performed. All parts of the fireplace that are removed for servicing must be replaced prior to operation. Cleaning the Media and Burner.

  1. With all parts of the fireplace at room temperature, carefully remove and clean the fire media with a soft bristled brush.
  2. Clean the pilot shield with a vacuum cleaner.

Cleaning the Stainless Steel.

  1. With all parts of the fireplace at room temperature, use a high-quality stainless steel cleaner to clean. Be sure to softly clean WITH the grain.

Cleaning the Cabinet.

  1. Ensure that the space beneath the glass panels is kept free of dirt and debris. Clean this area with a vacuum cleaner while being careful to not disturb any of the wiring or tubing.
  2. Ensure that the cabinet drain is free of blockage and debris.

Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that the control compartments, burners, and circulating-air passageways of the appliance are kept clean.
The flames should look like Figure 22. The pilot flame should look like Figure 23.

European Home JVF40H Outdoor Gas Fireplace -FIGURE 2

European Home JVF40H Outdoor Gas Fireplace
-MAINTENANCE

JVF-40H SERIES REPLACEMENT PARTS LIST

Part Description| Part Number
24” Connection Wire| Repl-JVF-GS-CWC-01
72” 8 Pin Wiring Harness| Repl-JVF-GS-MWH-01
AC Adapter| Repl-JVF-GS-AC-ADAPTER
Clear Glass (40H-S only) (1 Piece)| JVF-GlASS-40H-S-ClEAR
Clear Glass (40H-ST only) (2 Pieces)| JVF-GlASS-40H-ST-ClEAR
Frosted Glass (40H-S only) (2 Pieces)| JVF-GlASS-40H-S-FROST
Frosted Glass (40H-ST only) (2 Pieces)| JVF-GlASS-40H-ST-FROST
Control Module| Repl-JVF-GS-CM-01
Gas Valve| Repl-JVF-GS-GV-M2-01
lED light System Kit| Repl-JVF-ES-40H-lED
log Set| E4-lSE-418 II
Momentary Contact Switch| Repl-JVF-ES-MCS-01
Pilot assembly| Repl-JVF-GS-PS-M2-01
Remote Control| Repl-JVF-GS-RC-01
Rocker Switch| Repl-JVF-ES-RS-01
Thermocouple| Repl-JVF-GS-GS-1T-01
Wall Switch Box| REPl-JVF-ES-BOX
Wall Switch Cord Grip| REPl-JVF-ES-BOX-CG
Wall Switch Cover| REPl-JVF-ES-BOX-CVR

For replacement parts and customer service:
Contact your local Dealer

INSTALLATION RECORD

The installer should complete the Customer Record and the Installer Record, below. This information is necessary for any contact with European Home Technical Support.
The Customer Record remains with the customer and the Installer Record is kept by the installer.
CUSTOMER RECORD
MODEL: ____
DATE of PURCHASE:

DEALER: ____
INSTALLER NAME:
FIREPLACE S/N: __
DATE INSTALLED: ____
FUEL: __
MEASURED AFTER INSTALLATION
INLET PRESSURE:

MANIFOLD PRESSURE:
INSTALLER: Please complete and retain the installer Record, below.
INSTALLER RECORD
MODEL:

DATE of PURCHASE:
CUSTOMER: ____

INSTALLER NAME: __
FIREPLACE S/N: __
DATE INSTALLED:

FUEL: __
MEASURED AFTER INSTALLATION
INLET PRESSURE: ___
MANIFOLD PRESSURE: ____

WARRANTY

European Home Warranty for The J Series Outdoor Gas Fireplace
European Home warrants the gas controls and burner of the J Series Outdoor Gas Fireplace against defects in materials and workmanship for a period of TWO (2) YEAR from the date of original retail purchase. We warrant the J Series Outdoor Gas Fireplace  nd cover against defects in materials and workmanship for a period of FIVE (5) YEARS from the date of original retail purchase. If a defect exists, European Home will, at its option, either (1) provide needed components using new or refurbished replacement parts or (2) exchange the product with one which is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original product. A replacement product/part assumes the remaining warranty of the original product or ninety (90) days from the date of replacement or repair, whichever provides longer coverage for you. When a product or part is exchanged, any replacement item becomes your property and the replaced item becomes the property of European Home. All warranty claims must be submitted through the dealer from which you purchased the product. Check with your dealer in advance for any costs to you when arranging a warranty call. Shipping and/or delivery charges for parts are not covered by this warranty. Nothing in the above shall be deemed to imply that this warranty shall apply to work which has been abused, or neglected or shows evidence of changes or modifications by others with or without permit, damages caused by the acts of God, building settlement or moving, fire or vandalism. In addition, installation of this product that varies from the requirements stated in the instruction manual will void the warranty. European Home is a division of Europa Ja, Inc.

APPENDIX A

lP (PROPANE) CONVERSION
Applicable Models:
JVF-40H-S
JVF-40H-ST
JVF-60-M2-01
JVF-60-ST-M2-01
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the Authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
The JVF-SA-LPCK kit contains the following items:

PART NUMBER| DESCRIPTION| QTY.|
---|---|---|---
JVF-GS-REG/HOSE-02SPIS| 1-Series LP Regulator,36″ hose, 3/8″ female fitting| 1|
JVF-GS-SPIS| Spider Screen for 1-Series LP conversion| 2|
JVF-GS-OR-.064| .064 Orifice for J-Series LP conversion| |
JVF-GS-GL-FF| 1-Series Gas Line Flare Fitting for LP conversion| 1|
JVF-DL-CL-01-EN| JVF LP Conversion Label – English| 1|
J-Series LP Conversion Guide| Instructions for J-Series LP conversion| 1|

This kit is to be used to convert the J Series models from natural gas to propane. It is not to be used to convert any other models.
The conversion must be performed only by a qualified service person or agency.
If the fireplace or burner has been connected to natural gas, contact your local gas supplier to have the natural gas supply disconnected and removed.
The maximum and minimum inlet supply pressure is controlled by the regulator. It is set at a supply pressure of 11 inches water column.
The manifold pressure cannot be adjusted. It should be 10.3 inches water column. The propane input is rated at 65,000 Btu/hr.
For installations above 2000 feet elevation, check with local authorities or your propane supplier for proper deration. Please refer to page 15 for lP cylinder enclosure.
STOP! THIS CONVERSION MUST ONLY BE PERFORMED BY A QUALIFIED SERVICE AGENCY OR PERSON

  1. Remove any burner media and clean unit
  2. Remove glass capture panels and optional wind guard (if applicable).
  3. Remove frosted glass and clear glass from the light beds, store safely. Remove antenna on double sided.
  4. Snip zip ties on front light for single side and both side for see-through.
  5. unscrew front light at silver connector to remove light on single side, both on see-through. Store in safe place.European Home JVF40H Outdoor Gas Fireplace -AGENCY
  6. Remove 3 screws holding light reflector under where zip ties were with a 5/16” wrench. lift out and store.European Home JVF40H Outdoor Gas Fireplace -AGENCY 1
  7. Remove 3 screws holding in rear reflector with 5/16” wrench, lift out and store safely.
  8. Remove the six 3/8” nuts from the burner base.
  9. Remove the six #10 screw from the burners. Remove the perforated pilot shield from the left burner.
  10. Remove four 3/8” nuts and two #8 screws from the burners with a 5/16” wrench and remove the burners.European Home JVF40H Outdoor Gas Fireplace -AGENCY 2
  11. Remove the two natural gas orifices with a 9/16” wrench and replace with the two propane orifices.European Home JVF40H Outdoor Gas Fireplace -AGENCY 3
  12. To convert the Pilot from natural gas to propane, turn the pilot barrel 1/4 turn counter clockwise with a 7/16” wrench. Take care not to damage the metal orifice strip.European Home JVF40H Outdoor Gas Fireplace -APPENDIX A
  13. Slide the orifice strip so that lP is showing and tighten the pilot barrel. Reattach pilot guards.European Home JVF40H Outdoor Gas Fireplace -APPENDIX A 1
  14. Remove existing NG line from gas valve and install the 1/2” female flare x 3/8” male flare connector and the regulator hose on the valve inlet and tighten.European Home JVF40H Outdoor Gas Fireplace -tighten
  15. On gas valve, screw min rate screw all the way in for lP airflow.European Home JVF40H Outdoor Gas Fireplace -tighten 1
  16. Remove the #8 screws and air shutters from the burner inlet tubes.
  17. Slide the Spider Screen over the burner inlet tubes so that it covers the air inlet holes and screw holes.
  18. Replace the Pilot Shields and install the burners using the same fasteners. The assembled burner should have the same relationship as shown below.European Home JVF40H Outdoor Gas Fireplace -Remove 1
  19. The burner must be connected to a propane supply cylinder and leak tested. Open the propane supply cylinder and apply a leak test solution to the Regulator/Hose and the 1/2” Female Flare x 3/8” Male Flare fittings. The leak test solution can be made by adding 1 teaspoon dishwashing liquid to 1/2 cup of tap water. If bubbles appear, shut the propane cylinder valve and tighten the connection. When there are no leaks at the valve inlet, light the burner and apply the leak test solution to the orifice fittings and the corrugated manifold tube.
  20. Fill out the information on the conversion label and attach it to the burner base to the right of the control panel. Reattach burner back in case.
  21. Connect the Regulator/Hose to the propane cylinder and verify that the burner lights and performs properly.

INDEX

A
APPLIANCE
Certifications 8
Rating label 8
C
CERTIFICATIONS
listing label 8
CLEARANCES
Combustibles 10
Mantel 10
D
DIMENSIONS
Clearances to Combustibles 10
Fireplace 6
Weight 6
E
ELECTRIC
Gas Control Schematic 12
Installation 12
lighting Schematic 13
ENCLOSING THE FIREPLACE/FRAMING 16
F
FIRE MEDIA 20
FRAMING 16–17
Rough Opening 17
G
GAS
Install the Natural Gas Supply 14
Pressures 5
Propane (lP) Cylinder Enclosure 15
I
INSTALLATION 11–17
Dimensions 17
Electric 12
Fire Media 20 – 22
Framing 17
Gas 14
Installation Record 29
locating the Fireplace 11
Rough Opening 17
Sheltered (Enclosed) 11
L
LED 25
Operating 23
LISTING LABEL 8
LP
Enclosure 15
Pressures 5
Safety 3
M
MAINTENANCE 27 – 28
Burner 27
Cleaning 27
Fire Media 27
lED lights 27
Pilot 22
Replacement Parts 28
N
NATURAL GAS
Installation 14
Pressures 5
O
OPERATING THE FIREPLACE 23 – 25
Flames 23
lED lights 25
P
PRESSURES
Gas 5
R
ROUGH OPENING 17
S
SAFETY INFORMATION 3 – 4
lP GAS 4
SPECIFICATIONS
Certifications 8
Dimensions 6
Fireplace Parts 5
Gas Pressures 5
listing label 8
T
Troubleshooting 26
W
WARRANTY 25
Designed and manufactured in the united States by:

European Home Logo EUROPEAN HOME
a division of Europa Ja, Inc.
30 log Bridge Road
Building 300 – Suite 303
Middleton, MA 01949
www.europeanhome.comEuropean Home JVF40H
Outdoor Gas Fireplace -Bar Code

Documents / Resources

| European Home JVF-40H Outdoor Gas Fireplace [pdf] Instruction Manual
JVF-40H-S, JVF-40H Outdoor Gas Fireplace, Outdoor Gas Fireplace, Gas Fireplace, Fireplace, JVF-40H-ST
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals